| Plan Review Stops For Permit 04090215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-11-02 |
Time |
16:17 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2004-11-02 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2004-11-02 00:00:00 | BUILDING PROVISO: | | | | | | 803.4 FOAM PLASTIC TRIM SHALL NOT BE | | | USED AS INTERIOR TRIM. SEE EXCEPTION: | | | A) THE MINIMUM DENSITY IS 20LBS/CU FT. | | | B) THE MAXIMUM THICKNESS OF THE TRIM IS | | | 1/2" AND THE MAXIMUM WIDTH IS 4".C) | | | THE TRIM CONSTITUTES NO MORE THAN | | | 10% OF THE WALL OR CEILING. | | | D) THE FLAMESPREAD RATING DOES NOT | | | EXCEED 75 WHEN TESTED PER ASTM E 84. | | | THE SMOKE DEVELOPMENT RATING IS | | | NOT LIMITED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-10-19 |
Time |
07:17 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2004-10-18 |
Time |
09:42 |
Sent To |
PC |
|
| Notes |
| 2004-10-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 04090215 | | | ADD: 201 S NARCISSUS AV | | | CONT: HOME TECHNICAL SERVICES, INC | | | TEL: (561)262-4068 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED, | | | PLANS INDICATE THE USE OF SOFFITS, NO | | | DETAILS FOR FASTENING TO THE STRUCTURE | | | ABOVE, NOR SPACING OF FRAMING OR FASTEN- | | | ING OF FRAMING. | | | | | | 3) 609.2.1 TYPE I OR II BUILDINGS, NO | | | COMBUSTIBLE MATERIALS IN WALLS, STUDS, | | | BACKING, ETC. | | | | | | 4) 704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | | | | 5)803.4 FOAM PLASTIC TRIM SHALL NOT BE | | | USED AS INTERIOR TRIM. SEE EXCEPTION: | | | A) THE MINIMUM DENSITY IS 20LBS/CU FT. | | | B) THE MAXIMUM THICKNESS OF THE TRIM IS | | | 1/2" AND THE MAXIMUM WIDTH IS 4". | | | C) THE TRIM CONSTITUTES NO MORE THAN | | | 10% OF THE WALL OR CEILING. | | | D) THE FLAMESPREAD RATING DOES NOT | | | EXCEED 75 WHEN TESTED PER ASTM E 84. | | | THE SMOKE DEVELOPMENT RATING IS | | | NOT LIMITED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-15 |
Time |
09:03 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-15 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2004-11-15 00:00:00 | SPECS SHEETS BROUGHT IN SHOWING LISTING | | | FOR MR SAUNA. | | | SPECS BROUGHT IN FOR STEAMIST DID NOT | | | SHOW ANY LSITING FROM A NRTL. | | | | | | PRINTED ADDITIONAL SPEC SHEET FOR | | | STEAMIST UNIT SHOWING LISTINGS. | | | | | | STAMPED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-01 |
Time |
10:37 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-01 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2004-11-01 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE ELECTRICAL PLANS ARE | | | OK, HOWEVER ELECTRICAL SPEC SHEETS FOR | | | NEW STEAM UNIT AND SAUNA WERE NOT | | | SUBMITTED. | | | SPEC SHEETS ALSO NEED OT SHOW LISTING | | | FROM A NRTL. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
17:39 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2004-10-05 00:00:00 | *********** UNSAT ******** | | | | | | 1)NOTE: PLEASE SHOW NEW CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | 215.5 | | | | | | 2)NOTE: PLEASE CORRELATE OCP AND AWG FOR | | | SOME ITEMS ON PANEL SCHEDULES. | | | 60A OCP W/ #8 | | | 20A OCP W/ #14 | | | COOKTOP, WATER HEATER, FRIG , EXISTING | | | COOKTOP. PLEASE SEE 310.16 75 DEGREE | | | COL. 110.14 | | | | | | 3)NOTE: PLEASE SUBMIT SPEC SHEETS FOR | | | NEW SAUNA/ STEAM UNITS. | | | LOADS SHOWN AT 5KW YET OCP IS SHOWN AT | | | 60A ALSO WITH #8 AWG?? | | | 310.16,215.5 | | | | | | 4)NOTE: PLEASE VERIFY NEW DISHWASHER | | | SHOWN AT 240V? | | | | | | 5)NOTE: PLEASE CLARIFY SOME AREAS OF | | | PLANS CALL FOR MINOR WORK, YET NOTHING | | | IS INDICATED? | | | | | | 6)NOTE: PLEASE SEE NOTE #8 OF ELECTRICAL | | | NOTES. PLEASE SEE NEC 336 OF THE 2002 | | | NEC, NMC IS NOT PERMITTED IN THIS BLDG. | | | THIS IS ONLY A NOTE FYI. | | | | | | 7)NOTE: PLEASE SEE BLDG REVIEW COMMENTS | | | IN REFERENCE TO REQUIRED UNITY OF TITLE. | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | WHICH MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-11-17 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-11-17 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-10-12 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-10-12 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2004-10-12 00:00:00 | SEE NOTES ON PERMIT 04090221 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-02-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-04 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-04 |
Time |
11:37 |
Sent To |
M |
|
| Notes |
| 2005-02-04 00:00:00 | TO PRAFTER DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2004-10-25 00:00:00 | TO COMM BD#41 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-10-19 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-09-16 |
Time |
08:47 |
Sent To |
PC |
|
| Notes |
| 2004-09-16 00:00:00 | TO COMM BD#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-01-05 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-05 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
prafter |
Date |
2005-01-05 |
Time |
13:54 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-10-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-10-19 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-10-19 |
Time |
07:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-17 |
Time |
15:45 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-17 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | PASSED/PROVISO | | | | | | T/P RELIEF VALVE FROM STEAM UNIT SHALL | | | DISCHARGE INTO THE EMERGENCY PAN OF THE | | | STEAM UNIT. THE DRAIN FROM THE STEAM | | | UNIT SHALL DISCHARGE INTO THE SHOWER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-09 |
Time |
15:14 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-10-09 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2004-10-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | | | | 1) SUBMIT A SANITARY RISER DIAGRAM THAT | | | INDICATES ALL ADDED FIXTURES. SHOW PIPE | | | SIZE AND VENTING FOR NEW FIXTURES. | | | SECTION 104.2.1 | | | 2) SUBMIT A DETAIL SHOWING PIPING FOR | | | THE RELIEF VALVE FOR THE STEAM UNIT. IN- | | | DICATE TERMINATION POINT FOR RELIEF VAL- | | | VE PIPING. SECTION 104.2.1 & 504.7.1. | | | 3) CLARIFY NOTE "MINOR WORK IN THESE | | | AREAS" | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|