| Plan Review Stops For Permit 04090021 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-16 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-16 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | REVISIONS TO SHEETS A2,A3,A6 & A9 ARE OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2004-12-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-02 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-02 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2004-12-02 00:00:00 | REVISION DENIED | | | | | | 1) SHEET A6 SPECIFIES A 6X6 WOOD COLUMN | | | AND DETAIL 3 ON A9 SPECIFIES A MULTIPLE | | | STUD COLUMN. PLEASE COORDINATE AND | | | SPECIFY THE GRADE AND SPECIES OF WOOD | | | REQUIRED. IF IT IS A MULTIPLE WOOD | | | COLUMN INDICATE THE NUMBER OF PLIES AND | | | THE FASTENERS, SPACING OF FASTENERS, | | | ADHESIVES, ETC. | | | | | | 2) THEIR IS NO MARK (4H)LISTED IN THE | | | ANCHOR SCHEDULE. DID YOU INTEND TO | | | SPECIFY 4-(H)ANCHORS. IF SO THE NUMBER | | | OF FASTENERS SPECIFIED FOR EACH END OF | | | THE STRAP DIFFER BETWEEN THE ANCHOR | | | SCHEDULE AND DETAIL 3 ON A9. | | | | | | IF YOU HAVE QUESTIONS CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-30 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-30 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2004-10-20 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-21 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2004-10-21 00:00:00 | DENIED | | | | | | 1) ONE HOUR FIRE RATED GLASS BLOCK IS | | | REQUIRED ON THE ZERO LOT LINE. PLEASE | | | SPECIFY THIS ON FLOOR PLAN. | | | | | | 2) FBC 11-4.23.2 REQUIRES AT LEAST ONE | | | FULL BATH TO HAVE A DOOR WITH A 29" | | | CLEAR OPENING. | | | | | | 3) SPECIFY THE POSITIVE AND NEGATIVE | | | WINDLOAD PRESSURES FOR THE SLIDING GLASS | | | DOOR AT THE DEN, OUTSWING DOOR AT THE | | | MASTER SUITE AND OVERHEAD GOLF CART DOOR | | | | | | 4) DETAIL 2 ON A9 SPECIFIES SEMCO | | | CONNECTORS. PLEASE UPDATE TO CONNECTORS | | | WITH STATE PRODUCT APPROVAL. | | | | | | 5) UPDATE THE REFERENCE TO ASCE 7-88 IN | | | THE GLASS BLOCK DETAIL ON A9. THE | | | CURRENT STANDARD IS ASCE 7-98. | | | | | | 6) SUBMIT THE UL OR OTHER LISTING | | | INFORMATION AND MANUFACTURER'S SPECS. | | | FOR THE ONE HOUR FIRE RATED GLASS BLOCK. | | | | | | 7) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE MOUNT, FASTENERS AND FASTENER | | | SPACINGS THAT WILL BE USED. | | | | | | 8)FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 9) SHEET A7 SPECIFIES THAT ATTIC VENTS | | | ARE NOT ALLOWED ON THE ZERO LOT SIDE. | | | ATTIC VENTS ARE ALLOWED ON ZERO LOT SIDE | | | IN THIS JURISDICTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-01 |
Time |
18:11 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-07-01 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
07:21 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | PLEASE SEE SOME MODELS SHOW THESE AS | | | "OPT". EACH PLAN MUST REFLECT THE ACTUAL | | | INSTALLATION PER WHICH ARE INSTALLED OR | | | NOT INSTALLED. | | | 215.5 | | | | | | 7)NOTE: PLEASE SEE MISSING RECEPT | | | REQUIRED IN BATHRM 210.52D. | | | | | | 8)NOTE: PLEASE SEE MISSING GFI ALONG | | | KITCHEN COUNTERSPACE. | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
20:29 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
20:28 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | | | | ******** NOTE ********** | | | | | | PLEASE SEE LOAD CALCS SHOWS HI-HAT LOAD | | | AT 35.25 KW? 47@75W IS 3525W?? | | | | | | PLEASE SEE BELOEW LOAD CALCS, SERVICE | | | INDICATES 200A'S YET RISER SHOWS | | | 300A'S. | | | | | | PLEASE SEE SERVICE SIZE HAS NOW BEEN | | | CHANGED TO A 300A SERVICE. | | | A #2 FOR GROUNDING ELECTRODE | | | CONDUCTOR.250.66 | | | | | | SERVICE MAY GO BACK TO 200A'S ONCE LOAD | | | CALCS ARE ADJUSTED DUE TO HI-HAT | | | LOAD.?? | | | | | | VERIFY OCP FOR AHU#2, 5KW W/ 50A OCP. | | | | | | THE ABOVE WAS REDLINED ON PLANS AND MAY | | | BE REVISED AFTER PERMIT IS ISSUED. | | | | | | | | | ** SENT TO PLUMB DUE TO NEW SHEETS IN | | | SETS.*** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:21 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-20 |
Time |
06:21 |
Sent To |
M |
|
| Notes |
| 2004-09-20 00:00:00 | **** UNSAT *** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 3)NOTE: PLEASE VERIFY OCP SHOWN FOR | | | WHAT APPEARS TO BE A 5KW HEAT-STRIP IN | | | \AHU #2. SHOWS 2P60A W/#6? | | | 424.3B | | | | | | 4)NOTE: PLEASE SEE NOTE #14 MENTIONS | | | SD'S TO WIRED INTO BATH /KIT LTS CIRCUIT | | | , PLEASE SEE THESE CIRCUITS WOULD THEN | | | BE REQUIRED TO BE ARC FAULT PER 210.12 | | | 2002 NEC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
18:00 |
Sent To |
E |
|
| Notes |
| 2005-07-01 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:46 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "BTROBAU" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-09 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-09 |
Time |
14:54 |
Sent To |
M |
|
| Notes |
| 2005-03-09 00:00:00 | TO PKRAUSS BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-10 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-10 |
Time |
13:15 |
Sent To |
B |
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO "ROB MCD" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-01 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-01 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
| 2004-12-01 00:00:00 | TO "ROB MCD" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
13:26 |
Sent To |
E |
|
| Notes |
| 2004-11-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-14 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | TO SFD RACK/E | | 2004-09-14 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-03-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-17 |
Time |
16:53 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-03-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:27 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
12:21 |
Sent To |
P |
|
| Notes |
| 2004-10-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.ENERGY & MANUAL J CALCULATIONS | | | SUBMITTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-22 |
Time |
07:36 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
07:36 |
Sent To |
B1 |
|
| Notes |
| 2004-11-22 00:00:00 | PASSED/PROVISO | | | | | | | | | REVISION REQUIRED FOR RISER DIAGRAM. | | | | | | TUB IS NOT VENTED IN BATH #3, SEE | | | EXAMPLE OF VENTED TUB BY RISER DIAGRAM. | | | | | | MASTER BATH SHOWS TWO TUBS ON RISER, THE | | | FLOOR PLAN SHOWS ONE TUB & ONE SHOWER | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
12:26 |
Rev Time |
1.00 |
| Received By |
gsalfeld |
Date |
2004-10-20 |
Time |
13:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-09-16 |
Time |
12:01 |
Sent To |
I |
|
| Notes |
|
|