| Plan Review Stops For Permit 04090020 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-30 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-30 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2004-10-20 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-21 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2004-10-21 00:00:00 | DENIED | | | | | | 1) ONE HOUR FIRE RATED GLASS BLOCK IS | | | REQUIRED ON THE ZERO LOT LINE. PLEASE | | | SPECIFY THIS ON THE FLOOR PLAN. | | | | | | 2) FBC 11-4,23,2 REQUIRES AT LEAST ONE | | | FULL BATH TO HAVE A DOOR WITH A 29" | | | CLEAR OPENING. | | | | | | 3) SPECIFY THE POSITIVE AND NEGATIVE | | | WINDLOAD PRESSURES FOR 7'X5' FIXED | | | WINDOW AT THE BREAKFAST NOOK AND THE | | | FRENCH DOOR AT THE CABANA BATH. | | | | | | 4) DETAIL 2 ON A9 SPECIFIES SEMCO | | | CONNECTORS. PLEASE CHANGE TO CONNECTORS | | | WITH STATE PRODUCT APPROVAL. | | | | | | 5) UPDATE THE REFERENCE TO ASCE 7-88 IN | | | THE GLASS BLOCK DETAIL ON A9. THE | | | CORRECT REFERENCE IS ASCE 7-98. | | | | | | 6) SUBMIT THE UL LISTING AND MANUFACT- | | | URER'S SPECS. FOR THE ONE HOUR FIRE | | | RATED GLASS BLOCK. | | | | | | 7) SUBMIT THE UL OR OTHER LISTING AND | | | SPECS. FOR THE PREFAB FIREPLACE AND THE | | | GAS BBQ. | | | | | | 8) THE CASEMENT WINDOWS IN BEDROOM #2 | | | MUST MEET EGRESS REQUIREMENTS OF FBC | | | 1005.4. | | | | | | 9) THE FLOOR PLAN SPECIFIES (2) 3080 | | | WOOD DOORS AT FRONT ENTRY, HOWEVER NO | | | PRODUCT APPROVALS FOR WOOD DOORS WERE | | | SUBMITTED. | | | | | | 10) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE MOUNT, FASTENERS, AND FASTENER | | | SPACINGS THAT WILL BE USED. | | | | | | 11) FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 12) SECTION 1 ON A7 SPECIFIES THAT NO | | | SOFFIT VENTS ARE ALLOWED ON ZERO LOT | | | SIDE. THIS JURISDICTION DOES ALLOW THESE | | | ON THE ZERO LOT SIDE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-01 |
Time |
18:24 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-07-01 |
Time |
18:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-17 |
Time |
13:09 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-05-17 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2005-05-17 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON | | | PLANS?? | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | 215.5 | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
20:48 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
20:48 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | | | | ******** NOTE ********** | | | | | | PLEASE SEE LOAD CALCS SHOWS HI-HAT LOAD | | | AT 37.5 KW? 50@75W IS 3750W?? | | | DUE TO POSSIBLE CHANGE IN LOAD CALCS, | | | SEE BELOW. | | | | | | PLEASE SEE SERVICE SIZE HAS NOW BEEN | | | CHANGED TO A 300A SERVICE. | | | A #2 FOR GROUNDING ELECTRODE | | | CONDUCTOR.250.66 | | | | | | THE ABOVE WAS REDLINED ON PLANS AND MAY | | | BE REVISED AFTER PERMIT IS ISSUED. | | | | | | VERIFY OCP FOR AHU#2. 5KW W/ 50A OCP. | | | | | | | | | ** SENT TO PLUMB DUE TO NEW SHEETS IN | | | SETS.*** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:40 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-20 |
Time |
06:40 |
Sent To |
M |
|
| Notes |
| 2004-09-20 00:00:00 | ******* UNSAT ****** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2)NOTE: PLEASE SEE OCP SHOWN FOR WHAT | | | APPEARS TO BE A 5KW HEAT-STRIP IN AHU | | | #2. SHOWN AS 60A AND #6. PLEASE VERIFY. | | | 424.3B | | | | | | 3)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS MAY BE REQUIRED | | | FOR REFERENCE ONLY BY OTHER REVIEWERS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
18:01 |
Sent To |
E |
|
| Notes |
| 2005-07-01 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-04-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-15 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-15 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2005-04-15 00:00:00 | TO "TROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-30 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-30 |
Time |
16:36 |
Sent To |
P |
|
| Notes |
| 2005-03-30 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
13:33 |
Sent To |
E |
|
| Notes |
| 2004-11-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-15 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | TO SFD RACK/E | | 2004-09-15 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:40 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
12:07 |
Sent To |
P |
|
| Notes |
| 2004-10-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW. ENERGY AND MANUAL J CALCULATIONS | | | ONLY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-22 |
Time |
08:46 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
08:46 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
12:20 |
Rev Time |
1.00 |
| Received By |
gsalfeld |
Date |
2004-10-20 |
Time |
12:57 |
Sent To |
B |
|
| Notes |
| 2004-10-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1 SANT. RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN. SECTION 104.2.1 | | | PIPE SIZE NOT CORRECT. BATHROOM MISSING | | | ECT. | | | | | | REVIEW BY GARY SALFELDER | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-09-16 |
Time |
16:52 |
Sent To |
I |
|
| Notes |
| 2004-09-16 00:00:00 | MUST PULL SEPARATE PERMIT FOR PRIVACY | | | WALL. |
|
|