| Plan Review Stops For Permit 04090017 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-01-11 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-01-11 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | REVISIONS TO CHANGE OPENINGS IN FAMILY | | | ROOM FROM FRENCH DOORS WITH SIDELITES TO | | | TWO SETS OF FRENCH DOORS IS OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-15 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-15 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2004-12-15 00:00:00 | BUILDING PROVISO | | | | | | PROVIDE ATTIC ACCESS TO ATTIC SPACE | | | ABOVE MASTER BEDROOM. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-30 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-30 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | DENIED | | | | | | 1) THE WINDLOAD PRESSURES FOR THE | | | BREAKFAST NOOK WINDOWS ARE GIVEN ON | | | SHEET A-6 WITH THE ARROW POINTING TO | | | THE | | | WRONG LOCATION. | | | | | | 2) ON SHEET A-5 TWO DIFFERENT SETS OF | | | WINDLOAD PRESSURES ARE SPECIFIED FOR | | | THE | | | GOLF CART GARAGE DOOR. SEE FRONT AND | | | LEFT ELEVATIONS. THE NEGATIVE PRESSURE | | | GIVEN FOR THE DOOR ON THE LEFT | | | ELEVATION | | | EXCEEDS THE DESIGN PRESSURE ON THE | | | PRODUCT APPROVAL. | | | | | | 3) THE ATTIC ACCESS IN THE CEILING OF | | | HIS WALK IN CLOSET ON THE FIRST FLOOR | | | WILL NOT PROVIDE ACCESS TO THE ATTIC | | | SPACE ABOVE THE MASTER SUITE BECAUSE IT | | | IS LOCATED BELOW THE SECOND FLOOR | | | BATHROOM. AN ACCESS THROUGH THE WALL OF | | | THE SECOND FLOOR WALK IN CLOSET INTO | | | THE | | | ATTIC SPACE OF MASTER SUITE WOULD BE | | | ADEQUATE. | | | | | | 4) A LARGE PORTION OF THE SECOND FLOOR | | | IS WOOD FRAME HOWEVER THE INSTALLATON | | | SCHEDULE FOR THE STORM PANELS SPECIFIES | | | CALK-IN FASTENERS WHICH ARE NOT FOR USE | | | IN WOOD. PLEASE CORRECT. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
gsalfeld |
Date |
2004-10-20 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-25 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2004-10-25 00:00:00 | DENIED | | | | | | 1) ONE HOUR FIRE RATED GLASS BLOCK IS | | | REQUIRED ON THE ZERO LOT LINE. PLEASE | | | SPECIFY THIS ON THE FLOOR PLAN. | | | | | | 2) FBC 11-4.23.2 REQUIRES AT LEAST ONE | | | FULL BATH ON THE FIRST FLOOR TO HAVE A | | | DOOR WITH A 29" CLEAR OPENING. | | | | | | 3) SPECIFY THE POSITIVE AND NEGATIVE | | | WINDLOAD PRESSURES FOR THE (2) 3050 | | | CSMT. WINDOWS IN BEDROOM #2, THE (2) | | | FRENCH DOORS WITH SIDELITES IN THE | | | FAMILY ROOM AND THE (3) FIXED GLASS | | | PANELS IN THE BREAKFAST NOOK. | | | | | | 4) UPDATE THE REFERENCE TO ASCE 7-88 IN | | | THE GLASS BLOCK DETAIL ON A12. IT SHOULD | | | BE ASCE 7-98. | | | | | | 5) SUBMIT THE LISTING INFORMATION AND | | | SPECIFICATIONS FOR THE ONE HOUR FIRE | | | RATED GLASS BLOCKS. | | | | | | 6) THE ATTIC ACCESS SPECIFIED IN THE | | | CEILING OF HIS W.I.C. ON THE FIRST FLOOR | | | IS WHERE THE FLOOR TRUSSES ARE LOCATED. | | | PLEASE CORRECT. | | | | | | 7) SPECIFY ATTIC ACCESS AT THE 3-CAR | | | GARAGE AND MASTER SUITE AS REQUIRED BY | | | FBC 2309.6. | | | | | | 8) THE CIRCULAR STAIRS ARE REQUIRED TO | | | HAVE A MINIMUM TREAD DEPTH OF 9" WITH A | | | 1" NOSING MEASURED 12" FROM THE SMALLER | | | RADIUS PER FBC 1007.8.3. PLEASE CLARIFY | | | THIS ON THE PLANS. | | | | | | 9) SAFETY GLAZING IS REQUIRED WITHIN 3' | | | HORIZONTALLY OF BATHTUBS OR SHOWERS PER | | | FBC 2405.2.1 IF LESS THAN 60" ABOVE THE | | | FLOOR OR WALKING SURFACE. SPECIFY TEMP. | | | GLASS AT 2ND FLOOR BATH #3 AND #4. | | | | | | 10) ATTIC VENTS ARE ALLOWED ON THE ZERO | | | LOT LINE SIDE. SEE NOTE ON A13. | | | | | | 11) SUBMIT A KEY PLAN AND INSTALLATION | | | SCHEDULE FOR THE STORM PANELS. SPECIFY | | | THE MOUNT, FASTENERS AND FASTENER | | | SPACING THAT WILL BE USED. | | | | | | 12)FBC 1005.4.5 (GLITCH AMENDMENTS | | | JULY 1, 2003) REQUIRES AT LEAST ONE | | | MEANS OF ESCAPE FROM A DWELLING WHEN | | | SHUTTERED FOR IMPACT PROTECTION. THE | | | MEANS OF ESCAPE SHALL BE WITHIN THE | | | FIRST FLOOR OF THE DWELLING AND CAN NOT | | | BE LOCATED IN A GARAGE. OCCUPANTS IN ANY | | | PART OF THE DWELLING SHALL HAVE ACCESS | | | TO IT WITHOUT HAVING TO PASS THROUGH A | | | LOCKABLE DOOR NOT UNDER THEIR CONTROL. | | | INDICATE HOW COMPLIANCE WILL BE | | | ACHIEVED. | | | | | | 13) THE ENTRY DOORS ON A3 SPECIFIED AS | | | WOOD, HOWEVER, THE PRODUCT APPROVAL | | | SUBMITTED IS FOR FIBERGLASS DOORS. | | | PLEASE CLARIFY. | | | | | | 14) THE NEGATIVE PRESSURE SPECIFIED ON | | | A5 FOR THE 8'X8' GARAGE DOOR IS GREATER | | | THAN THE NEGATIVE DESIGN PRESSURE ON THE | | | PRODUCT APPROVAL. PLEASE CORRECT. | | | | | | 15) SPECIFY ON SHEET A3 OF THE PLANS | | | THAT THE DEN IS NOT TO BE USED AS A | | | SLEEPING ROOM OR PROVIDE EGRESS WINDOWS. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-29 |
Time |
20:01 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-08-29 |
Time |
20:01 |
Sent To |
|
|
| Notes |
| 2005-08-29 00:00:00 | ******** PLANS REDLINED ***** | | | | | | | | | | | | 1) PLEASE SEE LOAD FOR AHU ON PANEL "B" | | | HAS BEEN DECREASED TO CORRELATE WITH KW | | | RATING INDICATED ON LOAD CALCULATIONS, | | | HOWEVER, PLEASE SEE PANEL SCHEDULE STILL | | | INDICATES "60A" OVERCURRENT PROTECTION | | | FOR A 5KW HEAT STRIP? THIS IS OVERSIZED. | | | | | | 2) PLEASE SEE GROUNDING ELECTRODE | | | CONDUCTOR HAS NOW BEEN CHANGED TO A #1 ? | | | | | | PLEASE SEE PREVIOUS COMMENT MENTIONED A | | | 1/0 MIN IS REQUIRED FOR 400A SERVICE. | | | 250.66,310.15B6 | | | A NOTE WAS ADDED TO FEEDERS, HOWEVER | | | RISER WAS NOT CORRECTED. | | | RISER WENT FROM THE PREVIOUS #2 TO #1. | | | | | | THE ABOVE HAS BEEN REDLINED ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-24 |
Time |
15:21 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-08-24 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2005-08-24 00:00:00 | ** UNSAT *** | | | | | | | | | PLEASE SEE COMMENTS FROM PREVIOUS | | | REVIEW. | | | | | | 1)NOTE: PLEASE SEE PANEL "B" SHOWS AN | | | AHU WITH A 10KW HEATM HOWEVER LOADS | | | CALCS INDICATE A 5KW UNIT?? | | | PLEASE CORRELATE. | | | 215.5,220 | | | | | | 2)NOTE: PLEASE SEE GROUNDING ELECTRODE | | | WAS NOTED AND CHANGED UNDER FEEDERS TO | | | SUB-PANELS, HOWEVER PLEASE SEE GROUNDING | | | ELECTRODE CONDUCTOR SHOWN ON RISER STILL | | | SHOWS A #2. PLEASE CORRECT TO 1/0 MIN. | | | 250.66,310.15B6 | | | | | | 3)NOTE: REDLINED 210.52C1 FOR KITCHEN | | | GFI? THIS IS A REDLINED ITEM, HOWEVER | | | PLANS ARE COMING BACK. PLEASE SEE THIS | | | WAS NOT NOTED ON PREVIOUS NOTES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-18 |
Time |
20:30 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-08-18 |
Time |
20:19 |
Sent To |
|
|
| Notes |
| 2005-08-18 00:00:00 | ************ UNSAT ************* | | | | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM NOW | | | SHOWS OCP FOR EACH PANEL. PLEASE SEE | | | RISER NOW SHOWS PANEL "B" UPGRADED FROM | | | THE PREVIOUS 150A PANEL TO 200A BRKR | | | FEEDING A 200A PANEL. THIS IS OK, | | | HOWEVER PLEASE SEE FEEDERS WERE NOT | | | UPGRADED FROM 150A TO 200A. PLEASE SEE | | | 310.15B6 FOR MIN FEEDERS. | | | PLEASE SEE MIN CONDUIT SIZE PER TABLES | | | IN CHAPTER 9. | | | | | | 2)NOTE: PLEASE SEE NOW SERVICE IS BEING | | | SHOWN UPGRADED FROM PREVIOUS 300A'S TO | | | 400A'S. PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR IS TO BE A 1/0 PER | | | 310.15B6, 250.66. | | | | | | 3)NOTE: PLEASE SEE REVISED LOAD | | | CALCULATIONS FOR PANEL "B". PLEASE SEE | | | PANEL SCHEDULE INDICATES THREE CENTRAL | | | A/C SYSTEMS, 1-10KW AND TWO -5KW HEAT | | | STRIPS, PLEASE SEE LOAD CALCULATIONS | | | ONLY SHOW ONE 5KW UNIT? | | | PLEASE CORRELATE. | | | 215.5,220 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-18 |
Time |
09:28 |
Rev Time |
0.20 |
| Received By |
dpalmer |
Date |
2005-05-18 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2005-05-18 00:00:00 | ************ UNSAT ************ | | | | | | **PLEASE SEE PLANS AND RISER DIAGRAM | | | HAVE COMPLETELY CHANGED FROM ORIG PLANS. | | | | | | 1)NOTE: PLEASE SEE NEW RISER NOW | | | INDICATES THREE ELECTRICAL PANELS, | | | HOWEVER NO OCP IS SHOWN ON RISER FOR NEW | | | PANELS. | | | IS THERE NOW A PANEL SCHEDULE FOR NEW | | | METER/MAIN COMBO. | | | 215.5,240.4, 310.16 ETC. | | | | | | 2)NOTE: PLEASE SEE ONLY ONE PANEL IS | | | SHOWN ON ELECTRICAL PLANS AND RISER | | | SHOWS 3. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE NUMEROUS ITEMS ON | | | PANEL SCHEDULE INDICATE 20A OCP ON #14 | | | AWG. PLEASE SEE 310.16,240.4. | | | | | | 4)NOTE: | | | | | | 5)NOTE: PLEASE SEE A JACUZZI/WHIRLPOOL | | | TUB IS NOW ADDED TO PANEL SCHEDULE, | | | HOWEVER NO ELECTRICAL IS SHOWN ON PLANS. | | | PLEASE ALSO SEE 680.71 FOR REQUIRED | | | INDICATION OF GFI PROTECTION. | | | | | | 6)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PLANS WITH THE # OF | | | RECESSED LTS INDICATED ON PANEL | | | SCHEDULE/LOAD CALCULATIONS. | | | PLEASE SEE SOME MODELS SHOW THESE AS | | | "OPT". EACH PLAN MUST REFLECT THE ACTUAL | | | INSTALLATION PER WHICH ARE INSTALLED OR | | | NOT INSTALLED. | | | 215.5 | | | | | | 7)NOTE: | | | | | | 8)NOTE: | | | | | | PLEASE SEE MANY OF THESE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS ON PLANS AT | | | LOCATIONS OF NOTES. | | | | | | *** PLEASE BE SURE ALL PLANS ARE SIGNED | | | BY THE ARCHITECT OF RECORD. | | | FS 481.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-23 |
Time |
17:39 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-23 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | REDLINED | | | POOL EQUIPMENT SHOWN ON PLANS BUT NOT ON | | | PANEL SCHEDULE/LOAD CALCS. | | | THIS EQUIPMENT MAY NOT BE FULLY KNOWN AT | | | THIS TIME AND MAY BE REVISED ON PANEL | | | SCHEDULE AND LOAD CALCS BEFORE FINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-12 |
Time |
20:19 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-12 |
Time |
20:09 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | | | | | | | ******** NOTE ********** | | | | | | PLEASE SEE LOAD CALCS SHOWS HI-HAT LOAD | | | AT 48.0 KW? 64@75W IS 4.8KW?? | | | | | | PLEASE SEE SERVICE SIZE HAS NOW BEEN | | | CHANGED TO A 300A SERVICE. | | | A #2 FOR GROUNDING ELECTRODE | | | CONDUCTOR.250.66 | | | | | | THE ABOVE WAS REDLINED ON PLANS AND MAY | | | BE REVISED AFTER PERMIT IS ISSUED. | | | | | | | | | ** SENT TO PLUMB DUE TO NEW SHEETS IN | | | SETS.*** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:50 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-20 |
Time |
06:50 |
Sent To |
M |
|
| Notes |
| 2004-09-20 00:00:00 | ********* UNSAT ******* | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 3)NOTE: PLEASE VERIFY OCP SHOWN FOR | | | WHAT APPEARS TO BE A 5KW HEAT-STRIP IN | | | AHU #2. SHOWN W/ 60A W/ #6 AWG. | | | 424.3B | | | | | | 4)NOTE: PLEASE SEE NOTE #14 IN GENERAL | | | NOTES. MENTIONS SD'S TO WIRED W/ BATH/ | | | KITCHEN LTS. PLEASE SEE 210.12 2002 NEC, | | | THIS WOULD REQUIRE EITHER CIRCUIT TO BE | | | ARC FAULT PROTECTED. | | | | | | 5)NOTE: PLEASE SEE MASTER SUITE, RECEPT | | | REQUIRED TO BE W/IN 6' OF DOOR. | | | 210.52 | | | | | | **PLEASE SEE IDENTIFICATION OF SINGLE | | | GARAGE SHOWN AS 3-CAR GARAGE. THIS IS | | | ONLY A NOTE FOR WHAT APPEARS TO BE A | | | MISPRINT. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | ONE SET OF OLD MAY BE SUBMITTED FOR | | | REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-23 |
Time |
18:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-23 |
Time |
18:37 |
Sent To |
E |
|
| Notes |
| 2005-08-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-08-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-19 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-19 |
Time |
13:48 |
Sent To |
P |
|
| Notes |
| 2005-08-19 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-18 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-18 |
Time |
17:50 |
Sent To |
E |
|
| Notes |
| 2005-08-18 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
15:57 |
Sent To |
M |
|
| Notes |
| 2005-05-24 00:00:00 | TO "PKRAUSS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-16 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-16 |
Time |
14:38 |
Sent To |
E |
|
| Notes |
| 2005-05-16 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-16 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-16 |
Time |
13:37 |
Sent To |
E |
|
| Notes |
| 2005-02-16 00:00:00 | TO DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-01-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-07 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-07 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
| 2005-01-07 00:00:00 | TO "ROB MCD" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-10 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-10 |
Time |
11:12 |
Sent To |
B |
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO "ROB MCD" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-05 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-05 |
Time |
13:28 |
Sent To |
E |
|
| Notes |
| 2004-11-05 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-15 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | TO SFD RACK/E | | 2004-09-15 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
|
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-05-31 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-05-31 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
06:50 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
13:25 |
Sent To |
P |
|
| Notes |
| 2004-10-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW, ONLY ENERGY AND MANUAL J | | | CALCULATIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-08-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-31 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-08-31 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2005-08-31 00:00:00 | AS BUILTS PLUMBING RISER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-22 |
Time |
07:22 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
07:22 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
13:26 |
Rev Time |
1.00 |
| Received By |
gsalfeld |
Date |
2004-10-20 |
Time |
12:55 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-16 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-09-16 |
Time |
16:57 |
Sent To |
I |
|
| Notes |
| 2005-01-12 00:00:00 | WALL WILL BE BUILT AT THE SAME TIME OF | | | THE HOUSE.NO PERMIT IS REQUIRED TO BE | | | PULLED SEPERATE.APPROVED WITH | | | STURCTURE OF HOUSE. | | 2004-09-16 00:00:00 | MUST PULL SEPARATE PERMIT FOR PRIVACY | | | WALL MM |
|
|