Plan Review Details - Permit 04081476
Plan Review Stops For Permit 04081476
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-12-20 Cont ID  
Sent By lsmith Date 2004-12-20 Time 09:13 Rev Time 0.50
Received By lsmith Date 2004-12-20 Time 09:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-11-08 Cont ID  
Sent By gsalfeld Date 2004-09-21 Time 13:10 Rev Time 0.75
Received By lsmith Date 2004-11-08 Time 08:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-12-14 Cont ID  
Sent By btrobaug Date 2004-12-14 Time 10:55 Rev Time 0.33
Received By btrobaug Date 2004-12-14 Time 10:49 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-11-05 Cont ID  
Sent By btrobaug Date 2004-11-05 Time 18:16 Rev Time 0.33
Received By btrobaug Date 2004-11-05 Time 18:02 Sent To B
Notes
2004-11-05 00:00:00 
 THE ELECTRICAL SCHEMATIC SHOWS 1-1HP
 PUMP @ 30 AMPS & 1-2HP PUMP @50 AMPS.
 PLEASR CHECK NAMEPLATE FOR CORRECT
 AMPERAGES OR REFER TO TABLE 430.148
 NEC.
 PLEASE CORRECT AND RESUBMIT FOR REVIEW.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-09-16 Cont ID  
Sent By csiegber Date 2004-09-15 Time 14:41 Rev Time 0.25
Received By dpalmer Date 2004-09-16 Time 17:36 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-09 Cont ID  
Sent By mjacobs Date 2004-12-09 Time 08:07 Rev Time 0.00
Received By mjacobs Date 2004-12-09 Time 08:07 Sent To E
Notes
2004-12-09 00:00:00SENT TO "BT" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 14:56 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 14:56 Sent To P
Notes
2004-10-25 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-09-15 Cont ID  
Sent By csiegber Date 2004-09-15 Time 14:41 Rev Time 0.00
Received By csiegber Date 2004-09-15 Time 14:41 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-31 Cont ID  
Sent By mmclean Date 2004-09-14 Time 16:40 Rev Time 0.00
Received By csiegber Date 2004-08-31 Time 16:14 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-12-18 Cont ID  
Sent By jleech Date 2004-12-18 Time 13:57 Rev Time 0.75
Received By jleech Date 2004-12-18 Time 13:57 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-03 Cont ID  
Sent By kstevens Date 2004-11-03 Time 08:17 Rev Time 0.50
Received By kstevens Date 2004-11-03 Time 08:17 Sent To E
Notes
2004-11-03 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING
 POOLS
  
  
 A) COMMENTS FROM PREVIOUS REVIEW HAVE
 NOT BEEN ADDRESSED.
 1) FBC-2001 424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE
 FILTER. (DETAIL)
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-09-21 Cont ID  
Sent By csiegber Date 2004-10-25 Time 14:56 Rev Time 1.00
Received By gsalfeld Date 2004-09-21 Time 12:47 Sent To B
Notes
2004-09-21 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL OR ADD TO NOTES)
 2) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 3) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 4) TIME CLOCK REQUIRED PER ENERGY CODE
 SECTION 412.1.ABCD.2.4.3
  
 REVIEW BY GARY SALFELDER
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-09-14 Cont ID  
Sent By csiegber Date 2004-08-31 Time 16:14 Rev Time 0.00
Received By mmclean Date 2004-09-14 Time 16:40 Sent To I
Notes
***NONE***