Plan Review Details - Permit 04081314
Plan Review Stops For Permit 04081314
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-10-04 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 12:18 Rev Time 4.00
Received By lsmith Date 2004-10-04 Time 08:12 Sent To  
Notes
2004-10-04 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 1. THE THERMA TRU DOORS WILL REQUIRE
 HURRICANE PROTECTION PER THE PRODUCT
 APPROVAL.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-06-14 Cont ID  
Sent By btrobaug Date 2005-06-14 Time 14:09 Rev Time 0.50
Received By btrobaug Date 2005-06-14 Time 13:41 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-05-03 Cont ID  
Sent By dpalmer Date 2005-05-03 Time 18:39 Rev Time 0.40
Received By dpalmer Date 2005-05-03 Time 18:39 Sent To  
Notes
2005-05-03 00:00:00******** UNSAT *********
  
 PLEASE SEE REVISIONS APPEAR TO BE FOR
 FINALS. PLEASE SEE BELOW COMMENTS AND
 REDLINED PLANS.
  
 1)NOTE: PLEASE CORRELATE FEEDERS FOR
 POOL SUB PANEL. PLEASE SEE PANEL "B"
 WHICH SHOWS 3-#6'S AND SEE RISER.
 PLEASE SEE #OF #6'S SHOWN FOR AHU'S ,
 SEE KW , OCP AND AWG FOR COND UNITS.
  
 PLEASE ADJUST PER ACTUAL INSTALLATION.
  
 2)NOTE: PLEASE SEE 6KW LOAD SHOWN FOR
 COOKTOP ON 20A CIRCUIT AND #12. THIS
 APPEARS TO BE A GAS COOKTOP.
  
 3)NOTE: PLEASE SEE DRYER SHOWN @5KW ON
 20A CIRCUIT. PLEASE SEE PLANS INDICATE A
 GAS DRYER??
 PLEASE SEE 240.4,310.16
  
 4)NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 5)NOTE: PLEASE SEE KITCHEN COUNTERSPACE
 APPEARS TO HAVE A MISSING GFI PER
 210.52C1
 PLEASE SEE THIS AREA IS NOTED AS
 "PANTRY", HOWEVER, A COUNTER IS SHOWN
 INSTEAD?
  
 PLEASE SEE ONE SET OF PLANS HAVE BEEN
 REDLINED FOR AREAS NOTED. IF THERE ARE
 ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-31 Cont ID  
Sent By dpalmer Date 2004-08-31 Time 06:45 Rev Time 0.25
Received By dpalmer Date 2004-08-31 Time 06:40 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-28 Cont ID  
Sent By adarroug Date 2005-06-28 Time 16:17 Rev Time 0.00
Received By adarroug Date 2005-06-28 Time 16:17 Sent To P
Notes
2005-06-28 00:00:00TO "KSTEVENS" BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-06-01 Cont ID  
Sent By adarroug Date 2005-06-01 Time 14:02 Rev Time 0.00
Received By adarroug Date 2005-06-01 Time 14:02 Sent To E
Notes
2005-06-01 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-04-28 Cont ID  
Sent By adarroug Date 2005-04-28 Time 11:10 Rev Time 0.00
Received By adarroug Date 2005-04-28 Time 11:10 Sent To E
Notes
2005-04-28 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-04 Cont ID  
Sent By csiegber Date 2004-10-04 Time 08:12 Rev Time 0.00
Received By lsmith Date 2004-08-27 Time 10:57 Sent To  
Notes
2004-08-30 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-08-31 Time 06:45 Rev Time 0.30
Received By pkrauss Date 2004-09-16 Time 12:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-07-18 Cont ID  
Sent By jleech Date 2005-07-18 Time 10:34 Rev Time 0.33
Received By jleech Date 2005-07-18 Time 10:34 Sent To  
Notes
2005-07-18 00:00:00RISER DIAGRAM REVISION

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-09-15 Cont ID  
Sent By jleech Date 2004-09-15 Time 19:19 Rev Time 0.33
Received By jleech Date 2004-09-15 Time 19:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-27 Cont ID  
Sent By csiegber Date 2004-08-30 Time 10:57 Rev Time 0.00
Received By mmclean Date 2004-08-27 Time 16:06 Sent To I
Notes
2004-08-27 00:00:00MUST PULL SEPARATE PERMIT FOR POOL MM