| Plan Review Stops For Permit 04081314 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-16 |
Time |
12:18 |
Rev Time |
4.00 |
| Received By |
lsmith |
Date |
2004-10-04 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2004-10-04 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. THE THERMA TRU DOORS WILL REQUIRE | | | HURRICANE PROTECTION PER THE PRODUCT | | | APPROVAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-06-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-14 |
Time |
14:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-06-14 |
Time |
13:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-05-03 |
Time |
18:39 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-05-03 |
Time |
18:39 |
Sent To |
|
|
| Notes |
| 2005-05-03 00:00:00 | ******** UNSAT ********* | | | | | | PLEASE SEE REVISIONS APPEAR TO BE FOR | | | FINALS. PLEASE SEE BELOW COMMENTS AND | | | REDLINED PLANS. | | | | | | 1)NOTE: PLEASE CORRELATE FEEDERS FOR | | | POOL SUB PANEL. PLEASE SEE PANEL "B" | | | WHICH SHOWS 3-#6'S AND SEE RISER. | | | PLEASE SEE #OF #6'S SHOWN FOR AHU'S , | | | SEE KW , OCP AND AWG FOR COND UNITS. | | | | | | PLEASE ADJUST PER ACTUAL INSTALLATION. | | | | | | 2)NOTE: PLEASE SEE 6KW LOAD SHOWN FOR | | | COOKTOP ON 20A CIRCUIT AND #12. THIS | | | APPEARS TO BE A GAS COOKTOP. | | | | | | 3)NOTE: PLEASE SEE DRYER SHOWN @5KW ON | | | 20A CIRCUIT. PLEASE SEE PLANS INDICATE A | | | GAS DRYER?? | | | PLEASE SEE 240.4,310.16 | | | | | | 4)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 5)NOTE: PLEASE SEE KITCHEN COUNTERSPACE | | | APPEARS TO HAVE A MISSING GFI PER | | | 210.52C1 | | | PLEASE SEE THIS AREA IS NOTED AS | | | "PANTRY", HOWEVER, A COUNTER IS SHOWN | | | INSTEAD? | | | | | | PLEASE SEE ONE SET OF PLANS HAVE BEEN | | | REDLINED FOR AREAS NOTED. IF THERE ARE | | | ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-31 |
Time |
06:45 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-31 |
Time |
06:40 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-28 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-28 |
Time |
16:17 |
Sent To |
P |
|
| Notes |
| 2005-06-28 00:00:00 | TO "KSTEVENS" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
14:02 |
Sent To |
E |
|
| Notes |
| 2005-06-01 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-28 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-28 |
Time |
11:10 |
Sent To |
E |
|
| Notes |
| 2005-04-28 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-04 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-08-27 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2004-08-30 00:00:00 | TO Z | | | TO SFD RACK/E |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-31 |
Time |
06:45 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-09-16 |
Time |
12:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-18 |
Time |
10:34 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-07-18 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | RISER DIAGRAM REVISION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-09-15 |
Time |
19:19 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-09-15 |
Time |
19:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-30 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-27 |
Time |
16:06 |
Sent To |
I |
|
| Notes |
| 2004-08-27 00:00:00 | MUST PULL SEPARATE PERMIT FOR POOL MM |
|
|