Plan Review Details - Permit 04081284
Plan Review Stops For Permit 04081284
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-09-09 Cont ID  
Sent By rmcdouga Date 2005-09-09 Time 08:42 Rev Time 0.00
Received By rmcdouga Date 2005-09-09 Time 08:42 Sent To  
Notes
2005-09-09 00:00:00REVISIONS TO SHEET 4 OF PLANS. REMOVED
 2- 25 SH WINDOWS IN FAMILY ROOM AND
 CHANGED SLIDING GLASS DOOR TO DOUBLE
 OUTSWING DOOR AT FAMILY ROOM.
  
 SUBMITTED STORM PANEL INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2005-09-02 Cont ID  
Sent By rmcdouga Date 2005-09-02 Time 14:52 Rev Time 0.00
Received By rmcdouga Date 2005-09-02 Time 14:52 Sent To  
Notes
2005-09-02 00:00:00STORM PANEL SUBMITTAL DENIED
  
 1) THE MEAN ROOF HEIGHT ON THE KEY PLAN
 IS INCORRECTLY LISTED AS 12'. THE MEAN
 ROOF HEIGHT IS 16' AS SPECIFIED ON THE
 PLANS.
  
 2) THE KEY PLAN IS MISSING THE 2-25SH
 WINDOWS AT THE REAR OF THE FAMILY ROOM.
 PLEASE CORRECT.
  
 3) THE DOOR AT THE FAMILY ROOM INDICATED
 AS THE EMERGENCY ESCAPE DOOR REQUIRED BY
 FBC 1005.4.5 ON THE KEY PLAN IS
 SPECIFIED AS A SLIDING GLASS DOOR ON THE
 PLANS. THE PRODUCT APPROVAL THAT YOU
 SUBMITTED IS FOR A DOUBLE SWINGING DOOR.
 THE SIGNED AND SEALED PLANS WILL NEED TO
 BE CHANGED FROM A SLIDING GLASS DOOR TO
 A DOUBLE SWINGING DOOR BY SUBMITTING
 REVISED PLANS. PLEASE BE AWARE THAT THIS
 ESCAPE AND RESCUE OPENING CAN BE AN
 IMPACT RESISTANT WINDOW THAT COMPLIES
 WITH THE REQUIREMENTS OF FBC 1005.4 FOR
 SLEEPING ROOMS AS LONG AS IT IS LOCATED
 IN A ROOM THAT DOES NOT REQUIRE THE
 OCCUPANTS OF THE HOME TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2005-08-01 Cont ID  
Sent By rmcdouga Date 2005-08-01 Time 13:23 Rev Time 0.00
Received By rmcdouga Date 2005-08-01 Time 13:22 Sent To  
Notes
2005-08-01 00:00:00STORM PANEL SUBMITTAL IS DENIED
  
 1)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 2) SUBMIT TWO COPIES OF AN INSTALLATION
 SCHEDULE. INDICATE OPENING SIZES,
 SHUTTER SPANS, FASTENER TYPE AND
 SPACINGS AND TYPE OF MOUNT THAT WILL BE
 USED. SEE ATTACHED SAMPLE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2005-03-18 Cont ID  
Sent By lmartine Date 2005-03-18 Time 09:45 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2005-03-18 00:00:00 
  
  
 ROOF REVISION NOT APPROVED
  
  
  
 PROVIDE SIGNED AND SEALED APPROVAL
 FROM DESIGNER OF RECORD, STATING
 EXISTING TRUSS SYSTEM WILL SUPPORT
 PROPOSED ROOF TILES.
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2005-01-03 Cont ID  
Sent By rmcdouga Date 2005-01-03 Time 15:15 Rev Time 0.00
Received By rmcdouga Date 2005-01-03 Time 15:15 Sent To  
Notes
2005-01-03 00:00:00BUILDING PROVISO
  
 SUBMIT TWO COPIES OF A KEY PLAN AND
 INSTALLATION SCHEDULE FOR THE STORM
 PANELS BEFORE INSTALLING THEM.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-13 Cont ID  
Sent By rmcdouga Date 2004-12-13 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2004-12-13 Time 07:24 Sent To  
Notes
2004-12-13 00:00:00DENIED
  
 1) THE WUSC 42 WOOD FRAME TO TRUSS
 CONNECTORS WERE NOT CHANGED TO THE
 CONCRETE TO TRUSS CONNECTORS ON ONE OF
 THE #6 SHEETS. ON THE OTHER SHEET ALL OF
 THESE CONNECTORS WERE CHANGED EXCEPT FOR
 ONE. PLEASE CORRECT.
  
 2) SOME OF THE PLAN SHEETS HAVE BEEN
 CHANGED USING WHITE OUT CORRECTION
 FLUID, WHICH IS NOT ALLOWED ON SIGNED
 AND SEALED DRAWINGS. NEW SHEETS WILL
 HAVE TO BE SUBMITTED FOR THESE.
  
 3) SHEET 8 OF 8 IS MISSING FROM THE
 PLANS.
  
 4) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS.
  
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-19 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 07:34 Rev Time 0.00
Received By rmcdouga Date 2004-10-19 Time 09:10 Sent To  
Notes
2004-10-19 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE ORIGINAL WET SIGNATURE AND TITLE
 BLOCK WITH NAME, ADDRESS AND LICENSE
 NUMBER IS REQUIRED ON EACH SHEET. SEE
 61G15-23.002.
  
 4) PROTECTION FROM TERMITES IS REQUIRED
 BY FBC 1816. PLEASE SPECIFY ON THE PLANS
  
 5) FBC TABLE 1606.2B INDICATES THAT THE
 NEGATIVE WINDOW LOAD PRESSURE FOR THE
 25SH WINDOWS (ZONE 4) WILL BE MORE THAN
 THE -36 PSF SPECIFIED ON THE PLANS.
 PLEASE CORRECT.
  
 6) SPECIFY THE SIZE OF THE ATTIC ACCESS
 ON THE PLANS. SEE FBC 2309.6.
  
 7) THE OWNER/AGENT IS REQUIRED TO SIGN
 THE ENERGY CALCULATION FORM. FBC CH.13.
  
 8)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 9) STRUCTURAL NOTE #1 ON SHEET 5 SHOULD
 BE CHANGED FROM 120MPH TO 140 MPH FOR
 WIND SPEED WITHIN THE CITY OF WPB. SEE
 FBC 1606.1.6.
  
 10) SPECIFY THAT THE NAILING NOTE ON
 SHEET 6 IS FOR ROOF SHEATHING.
  
 11) NOTE 12 ON SHEET 5 CALLS FOR 10D
 NAILS WHICH CONFLICTS WITH THE NOTE ON
 SHEET 6 WHICH SPECIFIES 8D NAILS. PLEASE
 CORRECT.
  
 12)USP WUSC 24 GIRDER TIES ARE SPECIFIED
 ON THE TRUSS LAYOUT ON SHEET 6. THESE
 ARE FOR ANCHORING TO WOOD FRAME, BUT
 ARE INDICATED IN AREAS THAT ARE MASONRY
 CONSTRUCTION. PLEASE CORRECT.
  
 13) SPECIFY THE TRUSS LOADS ON THE PLANS
 INCLUDING THE BOTTOM CORD LIVE LOAD,
 WHICH IS REQUIRED TO BE A MINIMUM OF
 10 PSF. SEE FBC TABLE 1604.1.
  
 14) SPECIFY THE MAXIMUM SPACING OF THE
 REINFORCED VERTICAL FILLED CELLS ON THE
 FOUNDATION PLAN.
  
 15) SPECIFY THE FOOTING SIZE AND REBAR
 FOR THE COLUMNS AT THE DEN FRONT.
  
 16) THE DEN FRONT DETAIL ON SHEET 6
 SPECIFIES ONE #5 IN THE NOTES, BUT THE
 DRAWINGS SHOW 3 REBARS ON SHEETS 6 & 7.
 PLEASE CORRECT.
  
 17) SPECIFY THE EMBED DEPTH OF THE 1/2"
 RED HEAD ANCHORS ON THE DEN FRONT DETAIL
 ON SHEET 6.
  
 18) SOME OF THE PLAN SHEETS THAT WERE
 SUBMITTED ARE ILLEGIBLE AND NOT CLEAR
 DRAFTSMAN QUALITY PLANS. PLEASE SUBMIT
 CLEAR READABLE PLANS.
  
 19) SPECIFY THE WINDOW TYPE AND SIZES
 FOR THE BEDROOM AND FAMILY ROOM.
  
 20) SUBMIT A KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS. SPECIFY
 THE ANCHOR TYPES, SPACINGS AND TYPE OF
 MOUNTING THAT WILL BW USED. SUBMIT
 COMPLETE PRODUCT APPROVALS AND INSTALL-
 ATION DRAWINGS WITH THE STATE PRODUCT
 APPROVAL NUMBER.
  
 21) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 22) SUBMIT STATE PRODUCT APPROVALS FOR
 THE FOLLOWING: DOUBLE OUTSWING FRONT
 DOOR, SLIDING GLASS DOORS, FIXED EYEBROW
 WINDOWS AND STRUCTURAL MULLIONS.
  
 23)THE PLANS SPECIFY FIBERGLASS SHINGLES
 ON THE WALL SECTION ON SHEET 5. HOWEVER,
 THE PRODUCT APPROVAL SUBMITTED IS FOR
 CEMENT ROOF TILES. PLEASE SUBMIT THE
 APPROPRIATE PRODUCT APPROVAL OR REVISE
 THE PLANS. TWO COMPLETE SETS OF PRODUCT
 APPROVALS WITH STATE COVER SHEETS ARE
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2005-05-02 Cont ID  
Sent By dpalmer Date 2005-05-02 Time 13:44 Rev Time  
Received By dpalmer Date 2005-05-02 Time 13:23 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-01-03 Cont ID  
Sent By rmcdouga Date 2005-01-03 Time 15:12 Rev Time 0.00
Received By rmcdouga Date 2005-01-03 Time 15:12 Sent To  
Notes
2005-01-03 00:00:00OK PER D. PALMER 12-23-04

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-12-03 Cont ID  
Sent By dpalmer Date 2004-12-03 Time 08:28 Rev Time 0.30
Received By dpalmer Date 2004-12-03 Time 08:12 Sent To P
Notes
2004-12-03 00:00:00********* UNSAT *************
  
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
 THIS RATING IS REQUIRED ON PLANS FOR
 EQUIPMENT TO BE INSTALLED.
 FIRST REVIEW NOTES:
  
 2)NOTE: PLEASE SEE ENTIRE AREA OF HAND-
 -DRAWN CHANGES AND ITEMS ON PLANS.
 PLEASE SEE FS 471.025 THIS IS NOT
 PERMITTED ON PLANS WHICH ARE SIGNED,
 DATED AND SEALED BY AN ENGINEER.
 PLEASE HAVE PLANS RE-PRINTED AND
 RE-SIGNED, DATED AND SEALED BY
 ENGINEER.
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW SHEETS INTO TWO COMPLETE
 SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-31 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 16:23 Rev Time 0.50
Received By dpalmer Date 2004-08-31 Time 07:10 Sent To M
Notes
2004-08-31 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR
 MISSING INFORMATION REQUIRED ON TITLE
 BLOCK FOR ENGINEER OF RECORD.
 FS 471.025
 PLEASE ALSO SIGN WITH COMPLETE "LEGAL"
 SIGNATURE. PLANS APPEAR TO HAVE INITIALS
 WHICH ARE NOT ACCEPTABLE.
 THIS IS REQUIRED ON ALL SHEETS WHEATHER
 OR NOTE COMMENT COMES FROM OTHER REVIEW-
 -ERS.
 PLEASE ALSO SEE FBC 104.2.1
  
 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 3) NOTE: PLEASE SHOW GROUNDING ELETRODE
 SYSTEM PER 250.50. FOOTER STEEL/COLD
 WATER/ ETC. SIZE ALL PER 250.66
  
 4 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 5)NOTE: PLEASE SEE AHU/HEAT LOAD SHOWN
 AT 2KW. PLEASE CORRELATE OCP/AWG AND
 KW LOAD SHOWN ON MECH PLANS.
 PLEASE SEE 424.3B FOR OCP.
  
 6)NOTE: PLEASE SHOW LOAD CALCULATIONS W/
 OUT ASSUMED LOAD OF PANELS B AND C.
  
 7)NOTE: PLEASE PROVIDE INFORMATION ON
 MAIN?? NONE INDICATED. SIZE, ETC.
 225.31
  
  
 8)NOTE: PLEASE SHOW A/C EQUIPMENT ON
 PLANS.
 DISC MEANS PER 440.11
 RECEPT PER 210.63
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-09-07 Cont ID  
Sent By adarroug Date 2005-09-07 Time 16:49 Rev Time 0.00
Received By adarroug Date 2005-09-07 Time 16:49 Sent To B
Notes
2005-09-07 00:00:00TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-08-30 Cont ID  
Sent By adarroug Date 2005-08-30 Time 15:57 Rev Time 0.00
Received By adarroug Date 2005-08-30 Time 15:56 Sent To B
Notes
2005-08-30 00:00:00TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-28 Cont ID  
Sent By adarroug Date 2005-07-28 Time 18:41 Rev Time 0.00
Received By adarroug Date 2005-07-28 Time 18:41 Sent To B
Notes
2005-07-28 00:00:00TO "RMCDOUGAL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-04-27 Cont ID  
Sent By adarroug Date 2005-04-27 Time 11:39 Rev Time 0.00
Received By adarroug Date 2005-04-27 Time 11:39 Sent To E
Notes
2005-04-27 00:00:00TO "DPALMER" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-21 Cont ID  
Sent By mjacobs Date 2004-12-21 Time 12:25 Rev Time 0.00
Received By mjacobs Date 2004-12-21 Time 12:25 Sent To E
Notes
2004-12-21 00:00:00SENT TO "DP" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-12-01 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 16:22 Rev Time 0.00
Received By mjacobs Date 2004-12-01 Time 16:22 Sent To E
Notes
2004-12-01 00:00:00SENT TO "E" TO DP DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-19 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:25 Rev Time 0.00
Received By rmcdouga Date 2004-08-26 Time 16:10 Sent To  
Notes
2004-08-30 00:00:00TO SFD RACK/E
2004-08-26 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-05-04 Cont ID  
Sent By prafter Date 2005-05-04 Time 11:14 Rev Time 0.50
Received By prafter Date 2005-05-04 Time 11:14 Sent To  
Notes
2005-05-04 00:00:00MECH. PLAN EEVISION IN TO CITY
 4/25/05. OK PR 5/4/05
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-13 Cont ID  
Sent By pkrauss Date 2004-12-13 Time 10:27 Rev Time 0.30
Received By pkrauss Date 2004-12-13 Time 10:27 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-08-31 Time 07:21 Rev Time 0.35
Received By pkrauss Date 2004-09-16 Time 07:04 Sent To B
Notes
2004-09-16 00:00:00DENIED:
 PLANS ARE TO BE SIGNED, SEALED & DATED
 IN ACCORDANCE WITH FS471.025 & THE
 FAC61G15-23.002.PLANS ARE OTHERWISE
 CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2005-01-01 Cont ID  
Sent By jleech Date 2005-01-01 Time 09:43 Rev Time 0.50
Received By jleech Date 2005-01-01 Time 09:43 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-12-11 Cont ID  
Sent By jleech Date 2004-12-11 Time 07:17 Rev Time 0.50
Received By jleech Date 2004-12-11 Time 07:17 Sent To B1
Notes
2004-12-11 00:00:00DENIED;
 NO HAND DRAWN NOTES PERMITED ON SEALED
 DRAWINGS. SEE ELECTRICAL PLANREVIEW
 NOTES #2.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-09-15 Cont ID  
Sent By jleech Date 2004-09-15 Time 18:13 Rev Time 0.50
Received By jleech Date 2004-09-15 Time 18:13 Sent To  
Notes
2004-09-15 00:00:00DENIED;
 SEE ELECTRICAL PLAN REVIEW COMMENTS
 NOTE #1.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-27 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:25 Rev Time 0.00
Received By mmclean Date 2004-08-27 Time 15:25 Sent To I
Notes
2004-08-27 00:00:00APPROVED 8/26/04 BY SHIRLEY GRAHAM
 PLANNER 822-1458 MM