Plan Review Details - Permit 04081257
Plan Review Stops For Permit 04081257
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-11-12 Cont ID  
Sent By lsmith Date 2004-11-12 Time 10:24 Rev Time 1.00
Received By lsmith Date 2004-11-12 Time 10:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-11-01 Cont ID  
Sent By pschmitz Date 2004-11-01 Time 15:22 Rev Time 0.75
Received By lsmith Date 2004-11-01 Time 11:25 Sent To  
Notes
2004-11-01 00:00:00BUILDING PLAN REVIEW
  
 1. THE FLORIDA ENERGY CODE FORM IS
 STILL
 NOT SIGNED BY THE OWNER/AGENT.
  
 2. ADDITIONAL FEES STILL UNPAID
 TOTALING
 $1865.11.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-10-06 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 11:51 Rev Time 4.00
Received By lsmith Date 2004-10-06 Time 10:39 Sent To  
Notes
2004-10-06 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. THE ENERGY CODE FORM HAS TO BE SIGNED
 BY THE OWNER/AGENT.
  
 2. THE THERMA-TRU DOORS REQUIRE
 HURRICANE PANELS. NO INFORMATION HAS
 BEEN SUBMITTED FOR THE STORM PANELS.
  
 3. THERE ARE NO PRODUCT APPROVALS FOR
 THE SINGLE HUNG WINDOWS.
  
 4. THE FIXED WINDOWS UNDER 30' WILL
 REQUIRE HURRICANE PANELS.
  
 5. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE PBC CLERK'S OFFICE AND A
 COPY SUBMITTED BEFORE A PERMIT CAN BE
 PRINTED
  
 6. THERE ARE ADDITIONAL FEES OF
 $1865.11DUE.
  
 7. SUBMIT THE REQUIRED PRODUCT APPROVALS
 FOR THE STORM PANELS.
  
 8. THE LICENSES FOR THE A/C & BUILDING
 CONTRACTOR HAVE EXPIRED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-26 Cont ID  
Sent By dpalmer Date 2005-07-26 Time 18:20 Rev Time 0.33
Received By dpalmer Date 2005-07-26 Time 18:11 Sent To  
Notes
2005-07-26 00:00:00REDLINED 210.52H

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-22 Cont ID  
Sent By dpalmer Date 2004-10-22 Time 16:23 Rev Time 0.33
Received By dpalmer Date 2004-10-22 Time 16:23 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-08-31 Cont ID  
Sent By csiegber Date 2004-10-18 Time 15:21 Rev Time 0.25
Received By dpalmer Date 2004-08-31 Time 06:46 Sent To M
Notes
2004-08-31 00:00:00*** NOTES REDLINED ***
  
 1)NOTE: MISSING FRONT GFI RECEPT PER
 210.52E
  
 2)NOTE: MISSING ALL REQUIRED SD'S PER
 NFPA-72 8-1.4.1.6.2
  
 IF ANY REVISIONS ARE MADE TO PLANS,
 PLEASE ADDRESS ABOVE AT THAT TIME.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-25 Cont ID  
Sent By adarroug Date 2005-07-25 Time 11:36 Rev Time 0.00
Received By adarroug Date 2005-07-25 Time 11:36 Sent To E
Notes
2005-07-25 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-07-25 Cont ID  
Sent By adarroug Date 2005-07-25 Time 11:35 Rev Time 0.00
Received By adarroug Date 2005-07-25 Time 11:35 Sent To P
Notes
2005-07-25 00:00:00TO "P" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-08 Cont ID  
Sent By csiegber Date 2004-11-08 Time 11:01 Rev Time 0.00
Received By csiegber Date 2004-11-08 Time 11:01 Sent To P
Notes
2004-11-08 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-18 Cont ID  
Sent By pschmitz Date 2004-11-01 Time 15:22 Rev Time 0.00
Received By csiegber Date 2004-10-18 Time 15:21 Sent To E
Notes
2004-10-18 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-10-06 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:10 Rev Time 0.00
Received By lsmith Date 2004-08-26 Time 10:21 Sent To  
Notes
2004-08-30 00:00:00TO SFD RACK/E
2004-08-26 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-09-16 Cont ID  
Sent By dpalmer Date 2004-08-31 Time 06:54 Rev Time 0.35
Received By pkrauss Date 2004-09-16 Time 11:51 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-08-08 Cont ID  
Sent By jleech Date 2005-08-08 Time 08:47 Rev Time 0.33
Received By jleech Date 2005-08-08 Time 08:47 Sent To  
Notes
2005-08-08 00:00:00AS BUILTS PLUMBING RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-11-10 Cont ID  
Sent By kstevens Date 2004-11-10 Time 16:15 Rev Time 0.25
Received By kstevens Date 2004-11-10 Time 16:15 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-11-01 Cont ID  
Sent By pschmitz Date 2004-11-01 Time 15:22 Rev Time 0.00
Received By pschmitz Date 2004-11-01 Time 15:15 Sent To B
Notes
2004-11-01 00:00:00PLUMBING PLAN REVIEW DENIED FBC 2001
 SEC 909 WET VENTING.
 ONLY THE FIFTURE WITHIN THE BATH ROOM
 GROUP SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN.( WASH MACHINE)
 ANY ADDITONAL FIXTURES SHALL DISCHARGE
 DOWNSTREAM OF THE WET VENT.
 END OF COMMENTS,QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-09-15 Cont ID  
Sent By dpalmer Date 2004-10-22 Time 16:23 Rev Time 0.33
Received By jleech Date 2004-09-15 Time 19:18 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-08-27 Cont ID  
Sent By lsmith Date 2004-08-27 Time 10:31 Rev Time 0.00
Received By lsmith Date 2004-11-12 Time 10:31 Sent To B
Notes
2004-11-12 00:00:00APPROVED & STAMPED BY MMCLEAN 8/27/04 LS

Review Stop Z ZONING
Rev No 1 Status F Date 2004-11-01 Cont ID  
Sent By mmclean Date 2004-08-27 Time 15:10 Rev Time 0.00
Received By mmclean Date 2004-08-27 Time 15:10 Sent To I
Notes
2004-08-27 00:00:00MUST PULL A SEPARATE PERMIT FOR POOL MM


Account Summary | Usage Policy | Privacy Policy