| Plan Review Stops For Permit 04081123 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-05-23 |
Time |
09:05 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2005-05-23 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2005-05-23 00:00:00 | REVISION ADD WINDOW IN CLOSET OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-27 |
Time |
14:01 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-01-27 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-01-04 |
Time |
13:44 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2005-01-04 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2005-01-04 00:00:00 | DENIED | | | | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 4.ADDITIONAL PERMIT FEES OF $2146.84 | | | ARE DUE.SEE PREVIOUS REVIEW FOR BREAK | | | DOWN. | | | | | | 6. SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR ROOFING, STRAPS AND TIE-DOWNS AND | | | IMPACT PROTECTION. | | | ALL PRODUCT APPROVALS REWUIRE THE | | | FOLLOWING. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7.FBC 1707.4.4.2 WINDOW BUCK SHALL | | | EXTEND BEYOND THE INTERIOR FACE OF THE | | | FRAME SUCH THAT FULL SUPPORT IS | | | PROVIDED. | | | REVISE WINDOW BUCK DETAIL. | | | | | | 9.FBC 2309.6 SHOW SIZE AND LOCATION OF | | | ATTIC ACCESS. | | | | | | 10.FBC 3401.7.1.2.1 SHOW HOW SMOKE | | | DETECTORS WILL COMPLY WITH THIS | | | SECTION. | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-10-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
16:44 |
Rev Time |
2.75 |
| Received By |
alange |
Date |
2004-10-22 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2004-10-22 00:00:00 | DENIED | | | | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2. SEE ELECTRICAL REVIEW REGARDING | | | TITLEBLOCK INFORMATION THAT IS RQUIRED | | | BEFOREISSUING OF PERMIT. | | | | | | 3.SHOW HOW SMOKE DETECTORS WILL | | | COMPLY WITH 905.2 FBC | | | | | | 4.BUILDING VALUE TOO LOW BASED ON | | | SBCCI BUILDING VALUATION DATA. | | | 3240 SQ.FT. X $76.96 PER SQ.FT = | | | $249,350.ADDITIONAL PERMIT FEES OF | | | $2146.84 ARE DUE. | | | | | | 5.SUBMIT 2 COPIES OF ENERGY CALCS. | | | | | | 6.SUBMIT 2 COMPLETE SETS OF PRODUCT | | | APPROVALS FOR EXTERIOR DOORS, WINDOWS, | | | STRAPS AND TIEDOWNS, ROOFING AND | | | IMPACT PROTECTION. | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7.FBC 1707.4.4.2 WINDOW BUCKS SHALL | | | EXTEND BEYOND THE INTERIOR FACE OF THE | | | FRAME SUCH THAT FULL SUPPORT IS PROVIDED | | | | | | 8.SHOW HOW LEDGER WILL BE FASTENED | | | ON THE TRUSS LEDGER DETAIL. | | | | | | 9.FBC 2309.6 SHOW SIZE AND LOCATION | | | OF ATTIC ACCESS. | | | | | | 10.FBC 3401.7.1.2.1 SHOW HOW SMOKE | | | DETECTORS AND GFCI OUTLETS WILL COMPLY | | | WITH THIS SECTION. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | ART LANGE | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6672 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-08 |
Time |
19:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-08 |
Time |
19:29 |
Sent To |
PC |
|
| Notes |
| 2006-06-08 00:00:00 | PLANS FOR RE-STAMP, | | | | | | REDLINED RECEPT MISSING PER 210.52 WHICH | | | WAS ON RECORD SET. | | | | | | REDLINED ALL RECEPTS IN EXISTING | | | DWELLING IN LOCATIONS WHERE GFI | | | PROTECTION IS REQUIRED PER 210.8A, SHALL | | | BE BROUGHT UP TO GFI PROTECTION PER | | | CHAPTER 34 FOR EXISTING DWELLINGS. | | | | | | ** PLEASE KNOW, BOTH OF THE ABOVE ITEMS | | | ARE ON RECORD SET REV #2. PLANS | | | SUBMITTED FOR RE-STAMPED ARE ONLY | | | THROUGH REV #1. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-19 |
Time |
18:23 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-01-19 |
Time |
18:23 |
Sent To |
M |
|
| Notes |
| 2005-01-19 00:00:00 | ** ELECTRICAL PLANS STAMPED** | | | OK. | | | | | | ** PLEASE NOTE** PLANS ALSO INCLUDE | | | TEMPORARY ELECTRICAL SERVICE FOR | | | CONTRUCTION. TEMP POWER POLE DOES NOT | | | NEED SEPARATE ELECTRICAL PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-23 |
Time |
06:40 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-12-23 |
Time |
06:24 |
Sent To |
P |
|
| Notes |
| 2004-12-23 00:00:00 | ************ UNSAT 3RD REVIEW ********* | | | | | | PLEASE SEE MOST NOTES FROM ORIG REVIEW | | | HAVE NOTE BEEN CORRECTED. | | | | | | 1)NOTE: PLEASE SEE NOTES #'S: | | | 5,6,7,8,10,11,12. | | | PLEASE SEE COPY OF THESE NOTES ARE | | | ATTACHED. | | | | | | NEW NOTE DUE TO CHANGE IN PLANS. | | | | | | 1)NOTE: PLEASE SEE RISER NOW SHOWS A | | | NEW | | | 250A MCB, YET PANEL IS SHOWN AS 100A ON | | | PANEL SCHEDULE? | | | | | | | | | 2)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONALS. | | | A 4X FEE WILL BE ACCESSED TO DESIGN | | | PROFESSIONAL FOR PLAN REVIEW PORION OF | | | PERMIT FEE IF ANY OF THESE COMMENTS ARE | | | NOT ADDRESSED. | | | THIS IS ACTUALLY THE THIRD REVIEW BY | | | ELECTRICAL, HOWEVER CONTRACTOR?OB CLAIMS | | | PLANS NEVER WENT OUT FOR CORRECTIONS. | | | ONE COPY OF EACH ELECTRICAL PLAN IS NOW | | | BEING RETAINED FOR POSSIBLE REVIEW BY | | | THE FL BOARD OF ARCH'S, DBPR. | | | | | | PLEASE SEE A 10% RESUB WILL BE DUE IN | | | NEXT RE-SUB. | | | | | | PLEASE SEE AS REQUESTED ON PREVIOUS | | | REVIEWS, PLEASE REMOVE ALL OLD/VOIDED | | | SHEETS AND INSERT ONLY NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. ONE SET OF OLD SHEETS TO | | | BE SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
13:21 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
13:21 |
Sent To |
M |
|
| Notes |
| 2004-10-05 00:00:00 | *********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:39 |
Rev Time |
1.25 |
| Received By |
dpalmer |
Date |
2004-08-30 |
Time |
14:26 |
Sent To |
P |
|
| Notes |
| 2004-08-30 00:00:00 | ********* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G1-16.004 | | | PLEASE ALSO INCLUDE PRINTED NAME AND | | | LICENSE # FOR ARCH OF RECORD IN TITLE | | | BLOCK. | | | THIS IS REQUIRED ON ALL SHEETS. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 3)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | ** MISSING SD LEADING TO FLR ABOVE. ** | | | | | | 4)NOTE: PLEASE SEE MISSING RECEPT REQ'D | | | FOR A/C EQUIPMENT. 210.63 | | | PLEASE ALSO SHOW LOCATIONS FOR CU'S AND | | | PLEASE SEE 440.11 FOR DISC MEANS. | | | | | | 5)NOTE: PLEASE SEE 220.31B FOR LOAD | | | CALCULATIONS. | | | PLEASE ADJUST. | | | | | | 6)NOTE: PLEASE SEE 424.3B FOR OCP ON | | | HEAT OF AHU'S. | | | | | | 7)NOTE: PLEASE SEE 250.6,250.24, NO | | | EQUIPMENT GROUNDING TO BE INSTALLED | | | UNTIL AFTER THE FIRST MEANS OF DISC. | | | | | | 8)NOTE: PLEASE SEE MISSING RECEPT ON 2' | | | OF WALL IN MAST BR. 210.52 | | | | | | 9 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | 210.12 2002 NEC | | | | | | 10)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 11)NOTE: PLEASE SEE FBC CHAPTER 34 FOR | | | ADDTIONS TO EXSITING DWELLINGS. | | | PLEASE PROVIDE LAYOUT OF EXSIT. THIS IS | | | TO BROUGHT UP TO CODE OR IF EXISTING | | | MEETS 2002 NEC | | | PLEASE ALSO SEE SD'S TO MEET NFPA-72 | | | PER PREVIOUS NOTE. | | | | | | 12)NOTE: PLEASE SEE KVA SHOWN FOR A/C | | | AHU'S DO NOT APPEAR TO CORRELATE TO | | | LOAD CALCS? | | | | | | 13)NOTE: PLEASE ALSO SEE BLDG REVIEW | | | NOTES FOR VALUATION OF PERMIT. | | | SHOWN AT 45K FOR 3240 SQ FT. | | | VALUE TO BE ADJUSTED. PER FBC 104.6.5. | | | | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF OLD PLANS | | | FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-19 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-19 |
Time |
10:41 |
Sent To |
E |
|
| Notes |
| 2005-01-19 00:00:00 | TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-12-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-20 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-20 |
Time |
08:42 |
Sent To |
E |
|
| Notes |
| 2004-12-20 00:00:00 | SENT TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-24 |
Time |
09:39 |
Sent To |
E |
|
| Notes |
| 2004-09-24 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-23 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-20 |
Time |
14:26 |
Sent To |
Z |
|
| Notes |
| 2004-09-20 00:00:00 | TO MM/SUBMITTAL/RETURN TO DEE TO PUT | | | W/ORIG PLANS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-26 |
Time |
16:57 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-26 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-24 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-01-20 |
Time |
13:00 |
Rev Time |
2.00 |
| Received By |
prafter |
Date |
2005-01-20 |
Time |
13:00 |
Sent To |
B |
|
| Notes |
| 2005-01-20 00:00:00 | MECH. REV. | | | A/C PLANS/ENERG. CAULK. AND EQUIPMENT | | | INFORMATION SUPPLYED. | | | PAT RAFTER 561/805/6725 OR805/6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-01-04 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-01-04 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-01-04 |
Time |
|
Sent To |
|
|
| Notes |
| 2005-01-04 00:00:00 | PLAN DENIED | | | 1) CAN NOT INSTALL OUTDOOR AIR ON ROOF | | | SECTION 609.1.ABC.1#2 FLORIDA ENERGY | | | CODE. | | | 2) REFER TO SECTION 601.4 FBC(M)BALANCED | | | RERURN AIR SIZEING | | | 3) PLANS MUST BE STAMPED OR TITLE BLOCK | | | CUT OFF. | | | 4) DO NOT NEED RETURN AIR IN BATHROOM OR | | | CLOSET. | | | 5) REFER TO SECTION 307.2.3 AUXILIARY | | | DRAIN FBC.(M) | | | 6) REFER TO SECTION 1107.2.1 REFRIGERANT | | | PIPING | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
16:43 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
16:30 |
Sent To |
B |
|
| Notes |
| 2004-10-07 00:00:00 | DENIED: | | | COMMENTS FROM 1ST REVIEW NOT ADDRESSED. | | | SEE ATTACHED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
13:21 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-09-20 |
Time |
13:19 |
Sent To |
B |
|
| Notes |
| 2004-09-20 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE ENERGY CALCULATIONS | | | FOR THE ADDITIONAL PER 2001 FBC CHAPTER | | | 13 SUB-CHAPTER 6. | | | | | | 2.PROVIDE EQUIPMENT SCHEDULE. | | | | | | 3.PROVIDE A PLAN INDICATING DUCT AND | | | GRILLE SIZE, LAYOUT AND MATERIAL. | | | | | | 4.SEE ALSO COMMENT #1 BY DEWEY PALMER, | | | ELECTRICAL PLAN REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-12-29 |
Time |
18:56 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-12-29 |
Time |
18:56 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-30 |
Time |
14:41 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-09-16 |
Time |
18:51 |
Sent To |
M |
|
| Notes |
| 2004-09-16 00:00:00 | NO RISER DIAGRAM UN-ABLE TO DO PLUMBING | | | PLAN REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-09-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-09-23 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-09-23 |
Time |
12:09 |
Sent To |
B |
|
| Notes |
| 2004-09-23 00:00:00 | PULLED & ATTACHED PLANS MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-20 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-26 |
Time |
12:47 |
Sent To |
I |
|
| Notes |
| 2004-08-26 00:00:00 | DENIED, NEED TO PROVIDE 2 SETS OF PLANS. | | | SITE PLAN MUST SHOW SETBACKS FOR FRONT | | | SIDES & REAR TO SCALE.CALLED OWNER | | | LEFT MSG ON VOICE MAIL. MM | | | CUSTOMER PROVIDED 2ND COPY OF PLANS AND | | | WILL PROVIDE SITEPLANS WITH SETBACKS. MM |
|
|