Plan Review Details - Permit 04081100
Plan Review Stops For Permit 04081100
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-01-24 Cont ID  
Sent By shill Date 2005-01-24 Time 13:50 Rev Time 0.00
Received By shill Date 2005-01-24 Time 13:50 Sent To PC
Notes
2005-01-24 00:00:00INSPECTION LETTER, STEEL, PREPARED BY R.
 BALBIS, PE (ARDAMAN & ASSOC) DATED
 1/18/04

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-10-05 Cont ID  
Sent By shill Date 2004-10-05 Time 17:07 Rev Time 0.50
Received By shill Date 2004-10-05 Time 17:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-19 Cont ID  
Sent By dpalmer Date 2004-10-19 Time 13:08 Rev Time 0.25
Received By dpalmer Date 2004-10-19 Time 13:08 Sent To P
Notes
2004-10-19 00:00:00NOTED: ALL GRND CONNS TO BE LISTED FOR
 USE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-09-16 Cont ID  
Sent By csiegber Date 2004-10-13 Time 14:39 Rev Time 0.33
Received By dpalmer Date 2004-09-16 Time 14:33 Sent To  
Notes
2004-09-16 00:00:00**** UNSAT ****
  
 1)NOTE: PLEASE PROVIDE INFORMATION FOR
 NEW WP PANEL SHWON ON RISER.
 FEED/OCP/AWG ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-01-20 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 14:09 Rev Time 0.00
Received By mjacobs Date 2005-01-20 Time 14:09 Sent To B
Notes
2005-01-20 00:00:00TO "SH" DESK/LETTERS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-10-13 Cont ID  
Sent By csiegber Date 2004-10-13 Time 14:39 Rev Time 0.00
Received By csiegber Date 2004-10-13 Time 14:39 Sent To E
Notes
2004-10-13 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-31 Cont ID  
Sent By csiegber Date 2004-08-26 Time 17:00 Rev Time 0.00
Received By csiegber Date 2004-08-26 Time 17:00 Sent To  
Notes
2004-08-31 00:00:00TO COMM BD#3

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-08-24 Time 10:08 Rev Time 0.00
Received By csiegber Date 2004-08-24 Time 10:07 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-10-27 Cont ID  
Sent By kstevens Date 2004-10-27 Time 16:50 Rev Time 1.00
Received By kstevens Date 2004-10-27 Time 16:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-10-26 Cont ID  
Sent By kstevens Date 2004-10-26 Time 11:31 Rev Time 0.50
Received By kstevens Date 2004-10-26 Time 11:31 Sent To  
Notes
2004-10-26 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
  
 CHANGES TO A SIGNED AND SEALED SET OF
 PLANS SHALL NOT BE MADE WITH WHITE OUT
 AND HAND DRAWN CHANGES. PLANS SHALL BE
 CHANGED BY THE ENGINEER OF RECORD.
 SECTION 104.2.1.3
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-09-22 Cont ID  
Sent By dpalmer Date 2004-10-19 Time 13:08 Rev Time 2.00
Received By kstevens Date 2004-09-22 Time 15:10 Sent To  
Notes
2004-09-22 00:00:00DENIED
 REFERENCE: FBC-2001 424 SWIMMING POOLS
  
 1) SHT 2 EQUIPMENT SCHEDULE INDICATES 2
 VACUUM FITTINGS, BUT THE POOL PLAN SHOWS
 1 VACUUM FITTING. PLEASE CLAIRFY/CORREL-
 ATE. SECTION 104.2.1
 2) SHT 2 EQUIPMENT SECHEULE INDICATES A
 STATIC FITTING, BUT THE POOL PLAN SHOWS
 NO STATIC LINE. PLEASE CLAIRFY/CORRELATE
 SECTION 104.2.1
 3) SHTS 2 & 3 EQUIPMENT SCHEDULE SHOWS
 2 300 SF FILTERS, BUT EQUIPMENT ROOM
 PLAN VIEW INDICATES 1. PLEASE CLAIRFY/
 CORRELATE. SECTION 104.2.1
 4) WASTE FROM THE FILTER SHALL DRAIN IN-
 TO THE SANITARY SYSTEM AND THE OVERFLOW
 AND POOL DRAIN SHALL CONNECT TO THE
 STORM SYSTEM.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-25 Cont ID  
Sent By csiegber Date 2004-08-24 Time 10:08 Rev Time 0.00
Received By jroach Date 2004-08-25 Time 09:12 Sent To  
Notes
***NONE***