| Plan Review Stops For Permit 04080912 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-09-17 |
Time |
15:17 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-09-17 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-17 |
Time |
09:11 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-08-30 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-01 |
Time |
13:59 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-09-01 |
Time |
13:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-01 |
Time |
09:22 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-24 |
Time |
15:25 |
Sent To |
M |
|
| Notes |
| 2004-08-24 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE CORRELATE PANELS/MCB | | | FROM RISER AND PANELS . | | | RISER SHOWS PANELS AS 150'S AND PANELS | | | ARE SHOWN AS 200A'S. | | | PLEASE ALSO SEE LOAD ON PANEL "A" IS | | | SHOWN AT 149.16 W/ DERATING ALREADY | | | TAKEN INTO ACCOUNT?? | | | | | | 2)NOTE: PLEASE SEE POOL PANEL LOAD | | | SHOWN AT 10KW ON PANEL 'A'YET POOL PANEL | | | SHOWS LOAD AT 6KW?? | | | | | | 3 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | PLEASE SEE 2002 210.12 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-17 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-17 |
Time |
09:11 |
Sent To |
B |
|
| Notes |
| 2004-09-17 00:00:00 | TO LS DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-01 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-01 |
Time |
09:22 |
Sent To |
E |
|
| Notes |
| 2004-09-01 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-24 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-08-20 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2004-08-24 00:00:00 | TO SFD RACK/E | | 2004-08-20 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-07-29 |
Time |
14:41 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2005-07-29 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2005-07-29 00:00:00 | SUBMITTAL FOR EQUIPMENT CHANGE/SAME SEER | | | & TONNAGE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-16 |
Time |
08:26 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-09-16 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-01 |
Time |
14:10 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-28 |
Time |
06:22 |
Sent To |
P |
|
| Notes |
| 2004-08-28 00:00:00 | DENIED: | | | MANUAL J CALCULATIONS, SYSTEM #2 | | | INDICATES ONLY 12 SEER AND THE ENERGY | | | CALCULATIONS SHOW BOTH SYSTEMS SHALL BE | | | 12.6 SEER.THE EQUIPMENT SCHEDULE | | | INDICATES BOTH SYSTEMS AS 12 SEER. | | | PLEASE CORRELATE MANUAL J AND THE | | | EQUIPMENT SCHEDULE TO REFLECT THE | | | ENERGY CALCULATIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-28 |
Time |
06:30 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-08-28 |
Time |
11:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-24 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-24 |
Time |
09:46 |
Sent To |
I |
|
| Notes |
|
|