Plan Review Details - Permit 04080912
Plan Review Stops For Permit 04080912
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-09-17 Cont ID  
Sent By lsmith Date 2004-09-17 Time 15:17 Rev Time 1.00
Received By lsmith Date 2004-09-17 Time 15:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-08-30 Cont ID  
Sent By csiegber Date 2004-09-17 Time 09:11 Rev Time 2.00
Received By lsmith Date 2004-08-30 Time 11:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-01 Cont ID  
Sent By dpalmer Date 2004-09-01 Time 13:59 Rev Time 0.33
Received By dpalmer Date 2004-09-01 Time 13:57 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-24 Cont ID  
Sent By csiegber Date 2004-09-01 Time 09:22 Rev Time 0.50
Received By dpalmer Date 2004-08-24 Time 15:25 Sent To M
Notes
2004-08-24 00:00:00************* UNSAT **************
  
 1)NOTE: PLEASE CORRELATE PANELS/MCB
 FROM RISER AND PANELS .
 RISER SHOWS PANELS AS 150'S AND PANELS
 ARE SHOWN AS 200A'S.
 PLEASE ALSO SEE LOAD ON PANEL "A" IS
 SHOWN AT 149.16 W/ DERATING ALREADY
 TAKEN INTO ACCOUNT??
  
 2)NOTE: PLEASE SEE POOL PANEL LOAD
 SHOWN AT 10KW ON PANEL 'A'YET POOL PANEL
 SHOWS LOAD AT 6KW??
  
 3 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 PLEASE SEE 2002 210.12
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-17 Cont ID  
Sent By csiegber Date 2004-09-17 Time 09:11 Rev Time 0.00
Received By csiegber Date 2004-09-17 Time 09:11 Sent To B
Notes
2004-09-17 00:00:00TO LS DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-09-01 Cont ID  
Sent By csiegber Date 2004-09-01 Time 09:22 Rev Time 0.00
Received By csiegber Date 2004-09-01 Time 09:22 Sent To E
Notes
2004-09-01 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-30 Cont ID  
Sent By mmclean Date 2004-08-24 Time 09:46 Rev Time 0.00
Received By lsmith Date 2004-08-20 Time 10:01 Sent To  
Notes
2004-08-24 00:00:00TO SFD RACK/E
2004-08-20 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-07-29 Cont ID  
Sent By pkrauss Date 2005-07-29 Time 14:41 Rev Time 0.20
Received By pkrauss Date 2005-07-29 Time 14:41 Sent To  
Notes
2005-07-29 00:00:00SUBMITTAL FOR EQUIPMENT CHANGE/SAME SEER
 & TONNAGE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-09-16 Cont ID  
Sent By pkrauss Date 2004-09-16 Time 08:26 Rev Time 0.30
Received By pkrauss Date 2004-09-16 Time 08:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-08-28 Cont ID  
Sent By dpalmer Date 2004-09-01 Time 14:10 Rev Time 0.35
Received By pkrauss Date 2004-08-28 Time 06:22 Sent To P
Notes
2004-08-28 00:00:00DENIED:
 MANUAL J CALCULATIONS, SYSTEM #2
 INDICATES ONLY 12 SEER AND THE ENERGY
 CALCULATIONS SHOW BOTH SYSTEMS SHALL BE
 12.6 SEER.THE EQUIPMENT SCHEDULE
 INDICATES BOTH SYSTEMS AS 12 SEER.
 PLEASE CORRELATE MANUAL J AND THE
 EQUIPMENT SCHEDULE TO REFLECT THE
 ENERGY CALCULATIONS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-08-28 Cont ID  
Sent By pkrauss Date 2004-08-28 Time 06:30 Rev Time 0.33
Received By jleech Date 2004-08-28 Time 11:04 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-24 Cont ID  
Sent By mmclean Date 2004-08-24 Time 09:46 Rev Time 0.00
Received By mmclean Date 2004-08-24 Time 09:46 Sent To I
Notes
***NONE***