Plan Review Details - Permit 04080910
Plan Review Stops For Permit 04080910
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-10-21 Cont ID  
Sent By csiegber Date 2004-10-25 Time 16:16 Rev Time 1.00
Received By lsmith Date 2004-10-21 Time 07:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-10-12 Cont ID  
Sent By pkrauss Date 2004-10-19 Time 16:33 Rev Time 1.00
Received By lsmith Date 2004-10-12 Time 08:40 Sent To  
Notes
2004-10-12 00:00:00BUILDING PLAN REVIEW:
  
 1. PLANS MUST BE TAKEN TO PBC AND IMPACT
 FEES PAID. THE PLANS WILL BE STAMPED
 AND A RECEIPT ISSUED. THIS HAS TO BE
 DONE BEFORE A PERMIT CAN BE ISSUED.
  
  
 2. ADDITIONAL FEES ARE DUE.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-09-21 Cont ID  
Sent By jleech Date 2004-09-15 Time 17:57 Rev Time 3.00
Received By lsmith Date 2004-09-21 Time 11:46 Sent To  
Notes
2004-09-21 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERKS OFFICE AND A
 COPY SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 2. PLANS MUST BE TAKEN TO PBC AND IMPACT
 FEES PAID.THE PLANS WILL BE STAMPED
 AND A RECEIPT ISSUED.THIS HAS TO BE
 DONE BEFORE A PERMIT CAN BE ISSUED.
  
 3. SUBMIT THE FLORIDA PRODUCT APPROVALS
 FOR THE STRUCTURAL COMPONENTS (TRUSS
 STRAPS, ETC.)
  
 4. THE SQ. FT. HAS BEEN CORRECTED.
 ADDITIONAL FEES ARE DUE.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-11-22 Cont ID  
Sent By btrobaug Date 2005-11-22 Time 17:28 Rev Time 0.50
Received By btrobaug Date 2005-11-22 Time 17:11 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-05 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 06:15 Rev Time 0.25
Received By dpalmer Date 2004-10-05 Time 06:12 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-25 Cont ID  
Sent By csiegber Date 2004-09-24 Time 10:19 Rev Time 0.33
Received By dpalmer Date 2004-08-25 Time 09:24 Sent To M
Notes
2004-08-25 00:00:00******* UNSAT *********
  
 1)NOTE: PLEASE CORRELATE PANELS ON
 RISER AND PANELS. ONE SHOWS 150A PANELS
 AND OTHER SHOWS 200A PANELS.
 PLEASE ALSO SEE LOAD SHOWN AT 149.16
 EVEN AFTER DERATING HAS BEEN TAKEN??
  
 2)NOTE: PLEASE SEE LOAD SHOWN FOR POOL
 PANEL IS SHOWN AS 10KW ON PANEL "A" YET
 POOL PANEL DOES NOT INDICATE THIS LOAD.
  
 3 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 2002 NEC 210.12
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-10-25 Cont ID  
Sent By csiegber Date 2004-10-25 Time 16:16 Rev Time 0.00
Received By csiegber Date 2004-10-25 Time 16:16 Sent To B
Notes
2004-10-25 00:00:00TO LS DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-09-24 Cont ID  
Sent By csiegber Date 2004-09-24 Time 10:18 Rev Time 0.00
Received By csiegber Date 2004-09-24 Time 10:18 Sent To E
Notes
2004-09-24 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-09-21 Cont ID  
Sent By mmclean Date 2004-08-24 Time 12:27 Rev Time 0.00
Received By lsmith Date 2004-08-20 Time 10:01 Sent To  
Notes
2004-08-25 00:00:00TO SFD RACK/E
2004-08-20 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-10-19 Cont ID  
Sent By pkrauss Date 2004-10-19 Time 16:33 Rev Time 0.20
Received By pkrauss Date 2004-10-19 Time 16:29 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-10-08 Cont ID  
Sent By pkrauss Date 2004-10-08 Time 07:06 Rev Time 0.15
Received By pkrauss Date 2004-10-08 Time 07:03 Sent To  
Notes
2004-10-08 00:00:00DENIED:
 COMMENTS FROM THE FIRST REVIEW WERE
 NOT ADDRESSED.SEE ATTACHED.
 MANUAL J CALCS FOR ZONE 2 AND EQUIPMENT
 SCHEDULE NEEDS TO BE CORRECTED ALSO.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-08-28 Cont ID  
Sent By dpalmer Date 2004-10-05 Time 06:15 Rev Time 0.20
Received By pkrauss Date 2004-08-28 Time 07:48 Sent To P
Notes
2004-08-28 00:00:00DENIED:
 THE MANUAL J CALCULATIONS AND THE
 EQUIPMENT SCHEDULE ON PLAN SHEET M-1
 DO NOT MATCH THE ENERGY CALCULATIONS.
 THE ENERGY CALCULATIONS SHOW 12.6 SEER
 WHEREAS SYSTEM #2 ON THE MANUAL J & THE
 EQUIPMENT SCHEDULE SHOW ONLY 1 12 SEER.
 EQUIPMENT SHALL NOT BE LESS EFFICIENT
 THAN WHAT THE ENERGY CALCULATIONS
 DICTATE, PLEASE REVISE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-09-15 Cont ID  
Sent By pkrauss Date 2004-08-28 Time 07:54 Rev Time 0.33
Received By jleech Date 2004-09-15 Time 17:57 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2004-08-24 Cont ID  
Sent By mmclean Date 2004-08-24 Time 12:27 Rev Time 0.00
Received By mmclean Date 2004-08-24 Time 12:27 Sent To I
Notes
2004-08-24 00:00:00MUST PULL SEPARATE PERMIT FOR POOL/SPA
 & DECK MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-08-24 Cont ID  
Sent By mmclean Date 2004-08-24 Time 09:28 Rev Time 0.00
Received By mmclean Date 2004-08-24 Time 09:28 Sent To I
Notes
2004-08-24 00:00:00DENIED, SURVEY & SITEPLANS NOT MATCHING.
 SURVEY SHOWS LOT 25 AND SITEPLANS SHOWS
 LOT 2