| Plan Review Stops For Permit 04080907 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-10-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
16:17 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-10-21 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-10-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-20 |
Time |
06:42 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-10-12 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2004-10-12 00:00:00 | BUILDING PLAN REVIIEW | | | | | | 1. THE PLANS MUST BE TAKEN TO PBC FOR IM | | | PACT FEES. THEY WILL STAMP THE PLANS AND | | | ISSUE A RECEIPT. THIS MUST BE SUBMITTED | | | BEFORE A PERMIT CAN BE PRINTED. | | | | | | 2. THERE ARE ADDITIONAL FEES DUE. | | | | | | ANY QUESTIONS PLEASE CALL | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-09-15 |
Time |
17:56 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2004-09-21 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2004-09-21 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERKS OFFICE AND A | | | COPY SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 2. PLANS MUST BE TAKEN TO PBC AND IMPACT | | | FEES PAID.THE PLANS MUST BE STAMPED | | | BY THEM, A COPY OF THE PAID RECEIPT | | | SUBMITTED BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3. NEED FLORIDA PRODUCT APPROVALS FOR | | | THE STRUCTURAL COMPONENTS (TRUSS | | | STRAPS, ETC.) | | | | | | 4. THE SQ. FT. ON APPLICATION HAS BEEN | | | CORRECTED.ADDITIONAL FEES ARE DUE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-24 |
Time |
17:45 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-05-24 |
Time |
17:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-26 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-25 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2006-04-26 00:00:00 | PLANS REVISED AFTER ROUGH ELECTRICAL | | | INSOECTIONS. | | | INFORMATION SENT TO CHIEF ELECTRICAL | | | INSPECTOR. | | 2006-04-25 00:00:00 | ON HOLD AS REVISIONS ARE BEING | | | SUBMITTED AFTER ROUGH ELECTRICAL | | | INSPECTIONS HAVE BEEN DONE. | | | SEE JAKE LEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-03 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-03 |
Time |
07:05 |
Sent To |
PC |
|
| Notes |
| 2006-04-03 00:00:00 | *************UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | WITH PANELS. | | | PLEASE SEE RISER SHOWS PANELS AS 200A | | | MCB AND PANELS ARE SHOWN AS 150A? | | | | | | 2) NOTE: PLEASE SEE RISER SHOWS PANEL | | | "A" FEEDING A POOL "DISCONNECT", HOWEVER | | | PLANS SEEM TOIN DICATE A POOL | | | "PANEL".? | | | PLEASE ALSO SEE THAT PANEL "A" DOES NOT | | | INDICATE A FEED TO EITHER A POOL | | | DISCONNECT OR POOL PANEL. | | | PLEASE CORRELATE AND AADJUST PLANS AND | | | RISER. | | | PLEASE SEE PLANS DO NOT INDICAT EITHER A | | | POOL PANEL OR A POOL DISCONNECT AT THE | | | LOCATION OF POOL EEQUIPMENT? | | | ** PLEASEBE SURE TO UPDATE LOAD | | | CALCULATIONS. | | | ** PLEASE ADJUST CONTINUOUS LOADS AT | | | 125%. (POOL PUMP). 215.3,230.42 | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-09 |
Time |
21:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-09 |
Time |
20:49 |
Sent To |
PC |
|
| Notes |
| 2006-02-09 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE PLANS INDICATE AND | | | SHOW TWO COMPLETELT DIFFERENT RISER | | | DIAGRAMS. | | | IT IS UNCLEAR WHICH ONE IS FOR REVIEW. | | | IF THE RISER IS THE HANDRAWN ONE, PLEASE | | | CORRELATE WITH PLANS/ PANELS ETC. | | | IF HANDRAWN, WRONG SIZE GEC, FOR 400A | | | SERVICE BASED ON 250.66,310.15B6 | | | 1/0 MIN. | | | | | | 2)NOTE: PLEASE SEE MANY REQUIRED 20A | | | CIRCUITS ON PANEL "A" WHICH ARE SHOWN AS | | | 15A FOR SMALL APPL, DINING RM ETC. | | | 210.11C1,210.52B1 ETC | | | | | | 3)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52 | | | | | | 4)NOTE: PLEASE SEE NO HANDWRITTEN | | | CHANGES OR WHITE-OUT PERMITTED ON PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-14 |
Time |
15:40 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-12-02 |
Time |
09:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:20 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
06:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
10:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-25 |
Time |
14:23 |
Sent To |
M |
|
| Notes |
| 2004-08-25 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE PANELS. | | | RISER SHOWS 150A PANELS AND PANELS | | | INDICATE 200A PANELS? | | | PLEASE ALSO SEE PANELS INDICATE A 149.16 | | | A LOAD AFTER DERATING?? | | | | | | 2)NOTE: PLEASE SEE POOL PANEL LOAD | | | SHOWN AS 10KW ON PANEL 'A'. PLEASE | | | CORRELATE W/ POOL PANEL. | | | | | | 3 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | 2002 NEC 210.12 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2006-05-24 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2006-05-24 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2006-05-24 00:00:00 | ELEC REVISION GIVEN TO BILL TROBAUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-24 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-24 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
| 2006-04-24 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-31 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-31 |
Time |
15:07 |
Sent To |
E |
|
| Notes |
| 2006-03-31 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-06 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-06 |
Time |
09:04 |
Sent To |
E |
|
| Notes |
| 2006-02-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-25 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
16:17 |
Sent To |
B |
|
| Notes |
| 2004-10-25 00:00:00 | TO LS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-09-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-24 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-24 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2004-09-24 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-24 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-08-20 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2004-08-25 00:00:00 | TO SFD RACK/E | | 2004-08-20 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-20 |
Time |
06:41 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-10-20 |
Time |
06:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-08 |
Time |
06:39 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-10-08 |
Time |
06:28 |
Sent To |
|
|
| Notes |
| 2004-10-08 00:00:00 | DENIED: | | | COMMENTS FROM THE 1ST REVIEW WAS NOT | | | ADDRESSED. SEE ATTACHED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
06:20 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-08-28 |
Time |
07:57 |
Sent To |
P |
|
| Notes |
| 2004-08-28 00:00:00 | DENIED: | | | THE MANUAL J CALCULATIONS AND THE | | | EQUIPMENT SCHEDULE ON PLAN SHEET M-1 | | | DO NOT MATCH THE ENERGY CALCULATIONS. | | | THE ENERGY CALCULATIONS SHOW 12.6 SEER | | | WHEREAS SYSTEM #2 ON THE MANUAL J & THE | | | EQUIPMENT SCHEDULE SHOW ONLY 12 SEER. | | | EQUIPMENT SHALL NOT BE LESS EFFICIENT | | | THAN WHAT THE ENERGY CALCULATIONS | | | DICTATE, PLEASE REVISE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-28 |
Time |
08:01 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-09-15 |
Time |
17:56 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-24 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-24 |
Time |
12:38 |
Sent To |
I |
|
| Notes |
|
|