| Plan Review Stops For Permit 04080776 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-02-22 |
Time |
16:13 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2005-02-22 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2005-02-22 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. SUBMIT THE INSTALLATION SCHEDULE FOR | | | THE STORM PANELS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-31 |
Time |
08:32 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2005-01-31 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. ON MY FIRST REVIEW I REVIEWED THE | | | PRODUCT APPROVALS AND STAMPED THEM | | | 8/31/04.THE PERMIT PACKAGE I RECEIVED | | | FROM 1/27/05 HAS 1 SET OF MY ORIGINAL | | | REVIEWED PRODUCT APPROVALS AND A PHOTO | | | COPY OF THE REVIEWED PRODUCT APPROVALS | | | WITH THE 8/31/04 STAMP ON THEM.WHERE | | | ARE THE ORIGINAL PRODUCT APPROVALS I | | | STAMPED? | | | | | | 2. THE STORM PANEL INSTALLATION | | | SCHEDULE | | | IS MISSING. RESUBMIT SHOWING ANCHORING | | | SCHEDULE & OPENINGS BEING PROTECTED | | | WITH | | | THE STORM PANELS. | | | | | | 3. FL SITE SPECIFIC APPLICATIONS WERE | | | RESUBMITTED 1/27 WITH DRAWINGS BY | | | THOMAS | | | M KELAHER, P.E. IF THE BUTT GLASS | | | WINDOWS ARE BEING DELETED THESE SHOULD | | | BE REMOVED. | | | | | | 4.SHEET A-1 NEEDS TO BE CORRECTED | | | SHOWING THE CHANGE FROM THE BUTT GLASS | | | WINDOWS REFERENCED IN THE 2/14/05 | | | LETTER | | | FROM JAMES E GILGENBACH. THE LETTER | | | SUBMITTED ARE BOTH PHOTO COPY OF | | | ENGINEER SIGNATURE. NEED ORIGINAL | | | SIGNATURE PER STATE STATUTE. | | | | | | 5. FL PRODUCT APPROVALS & DADE COUNTY | | | PRODUCT APPROVALS NEED TO BE SUBMITTED | | | FOR THE FIXED GLASS WINDOWS TO BE USED | | | IN THE BREAKFAST AREA & MASTER BEDROOM. | | | INCLUDE THE PRODUCT APPROVALS FOR THE | | | MULLIONS. | | | | | | 6. WHAT PRODUCT APPROVAL PERTAINS TO | | | THE | | | FIXED WINDOWS IN THE LIVING ROOM? | | | | | | NOTE: BECAUSE OF THE VARITY OF WINDOWS | | | & | | | DOORS BEING USED IN THIS HOUSE THE | | | PRODUCT APPROVALS SHOULD BE LABELED | | | WITH | | | WHICH OPENINGS THEY COVER. THIS WOULD | | | CUT DOUWN ON THE REVIEW TIME AND BE | | | EASIER FOR THE BUILDING INSPECTOR | | | DURING | | | HIS INSPECTION. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-01-11 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-11 |
Time |
15:02 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2005-01-11 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2005-01-11 00:00:00 | BUILDING PLAN REVIEW FAILED: | | | | | | 1. THERE IS AN UNPAID BALANCE FOR | | | PERMIT | | | FEES DUE TOTALING $909.54 | | | | | | 2. BUTT GLASS ASSEMBLY: THE SITE | | | SPECIFIC FORM IS NOT FILLED OUT | | | CORRECTLY. SEE HIGHLIGHTED AREAS. THE | | | APPLICANT'S TECHNICAL REP. CANNOT BE | | | THE | | | SAME AS THE THIRD PARTY QUALITY | | | ASSURANCE ENTITY THIS WOULD CAUSE A | | | CONFLICT OF INTEREST. SUBMIT THE DADE | | | COUNTY PRODUCT APPROVAL FOR THE ARCH | | | 4500 SERIES SHOWN ON THE ENGINEERS | | | PLANS. DADE COUNTY CAN BE THE THIRD | | | PARTY. | | | | | | 3. A NOTICE OF COMMENCEMENT MUST BE | | | SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-08-28 |
Time |
10:38 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2004-08-31 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2004-08-31 00:00:00 | | | | BUILDING PLAN REVIEW: FAILED | | | | | | 1. ENERGY FORM IS NOT SIGNED BY | | | OWNER/AGENT. | | | | | | 2. PLAN SHOWS BUTT GLASS ASSEMBLY. | | | SUBMIT PRODUCT APPROVALS FOR THE BUTT | | | GLASS INCLUDING STATE PRODUCT APPROVAL. | | | SUBMIT ENGINEERING FOR BUTT GLASS | | | ASSEMBLY SIGNED AND SEALED BY | | | ENGINEER.AN INSPECTION BY ENGINEER IS | | | REQUIRED WHEN WINDOWS ARE INSTALLED. A | | | LETTER SIGNED AND SEALED BY THE | | | ENGINEER WITH THE RESULTS OF THE | | | INSPECTION IS REQUIRED BEFORE C/O. | | | | | | 3. PLANS MUST BE TAKEN TO PBC AND | | | IMPACT FEES PAID AND PLANS STAMPED | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 4. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERKS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 5. THE CALCULATED VALUE IS UNDERSTATED,. | | | ADDITIONAL FEES OF $ARE DUE. | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-06 |
Time |
16:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-06 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-04-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-21 |
Time |
17:55 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-04-21 |
Time |
17:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-04 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-04 |
Time |
17:06 |
Sent To |
PC |
|
| Notes |
| 2006-04-04 00:00:00 | REV'S FOR BT OUT OF OFFICE. | | | | | | REDLINED SD LOCATION IN MASTER BEDRM TO | | | BE WITHIN 12" OF THE HIGHEST POINT ON A | | | FLAT CEILING. NFPA-72 11.8..3.5 | | | | | | METER/ PANELS ARE BACK TO BACK, VIF. | | | | | | | | | CIRCUIT FOR UTIL/HALL LTS, SHOWS 15A OCP | | | ON #12, WHICH IS OK. | | | PLANS REDLINED, | | | | | | | | | EITHER FOYER OR LIVING ROOM RQUIRES A LT | | | FIXTURE OF SOME SORT FOR REQUIRED MEANS | | | OF EGRESS LIGHTING. 230.70, LS 101 7.8. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-07 |
Time |
12:30 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-12-07 |
Time |
12:30 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-28 |
Time |
14:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-28 |
Time |
14:10 |
Sent To |
PC |
|
| Notes |
| 2005-11-28 00:00:00 | | | | PASSED PLANS SUBMITTED ON 11/16 AFTER | | | CONVERSATION AND COMING TO AN AGREEMENT | | | WITH CHARLIE./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-11-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-23 |
Time |
15:58 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-23 |
Time |
14:33 |
Sent To |
PC |
|
| Notes |
| 2005-11-23 00:00:00 | | | | PANEL "P" DOES NOT COMPLY WITH 110.26 | | | CLEARANCE REQUIREMENTS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-01-28 |
Time |
11:31 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2005-01-28 |
Time |
11:30 |
Sent To |
B |
|
| Notes |
| 2005-01-28 00:00:00 | AIC RATING SUBMITTED WITH BLDG | | | REV../WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-12-23 |
Time |
09:44 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-12-23 |
Time |
09:24 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-23 |
Time |
13:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-23 |
Time |
11:46 |
Sent To |
M |
|
| Notes |
| 2004-08-23 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE GROUNDING ELECTRODE CONDUCTOR | | | MUST COMPLY WITH 250.66, #2 MIN. | | | | | | 2} THE FEEDERS FROM THE DISCONNECTS TO | | | THE PANELS MUST HAVE AN EQUIPMENT | | | GROUND SIZED PER 250.122. | | | | | | 3} THE LAUNDRY CIRCIUIT MUST BE | | | CALCULATED AT 1500 VA PER220.16(B). | | | | | | 4} PANEL "B" HAS # 14 CONDUCTORS WITH A | | | 20AMP OCP. SEE 310.16. | | | | | | 5} THE BATH CIRCUIT MUST COMPLY WITH | | | 210.11(C)(3), 20 AMP #12. | | | | | | 6} BEDROOM #2 RECEPTACLE SPACING MUST | | | COMPLY WITH 210.52(A)(1) SPACING. | | | | | | 7} THERE IS ONLY ONE DISCONNECT SHOWN AT | | | THE METER LOCATION BUT 2 ON THE RISER. | | | PLEASE CORRELATE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-20 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-20 |
Time |
16:29 |
Sent To |
M |
|
| Notes |
| 2006-09-20 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-30 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-30 |
Time |
16:27 |
Sent To |
E |
|
| Notes |
| 2006-06-30 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-12 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-12 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
| 2006-04-12 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-03 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-03 |
Time |
09:08 |
Sent To |
E |
|
| Notes |
| 2006-04-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-31 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-31 |
Time |
16:35 |
Sent To |
M |
|
| Notes |
| 2006-03-31 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-16 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-16 |
Time |
13:10 |
Sent To |
E |
|
| Notes |
| 2005-11-16 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-06 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-06 |
Time |
16:47 |
Sent To |
M |
|
| Notes |
| 2005-10-06 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-22 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-22 |
Time |
09:56 |
Sent To |
B |
|
| Notes |
| 2005-02-22 00:00:00 | TO LS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-28 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-28 |
Time |
08:46 |
Sent To |
B |
|
| Notes |
| 2005-01-28 00:00:00 | TO "LS" DESK/SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-21 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-21 |
Time |
15:37 |
Sent To |
E |
|
| Notes |
| 2004-12-21 00:00:00 | SENT TO "BT" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-19 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-08-18 |
Time |
12:17 |
Sent To |
|
|
| Notes |
| 2004-08-20 00:00:00 | TO SFD RACK/E | | 2004-08-18 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-10-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-10-19 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-10-19 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-03 |
Time |
12:04 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-04-03 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2006-04-03 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-10-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-10-13 |
Time |
13:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-10-13 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | MECH. REVISION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-10 |
Time |
07:03 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-01-10 |
Time |
06:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-23 |
Time |
13:23 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-25 |
Time |
06:29 |
Sent To |
P |
|
| Notes |
| 2004-08-25 00:00:00 | DENIED: | | | 1.PLEASE PROVIDE MANUAL J CALCULATIONS | | | ARE REQUIRED ALONG WITH THE ENERGY CALCS | | | PER 2001 FBC CHAPTER 13 SUB-CHAPER 600 | | | & 607.1.ABC.1. | | | | | | 2.PER THE REVISED 2001 FBC(M) 601.4 | | | EXCEPTION #3, ALL AIR INTO THE MASTER | | | SUITE IS TO BE INCLUDED FOR PROPER | | | SIZING OF THE RETURN AIR, (I.E. BATHROOM | | | CLOSET, ETC).RETURN AIR FROM THE | | | MASTER SUITE IS NOT SIZED PROPERLY FOR | | | BALANCED AIR RETURN. | | | | | | 3.PLAN DOES NOT INDICATE AIR MAKE UP | | | FOR THE GAS DRYER.PLEASE PROVIDE | | | CALCULATIONS FOR COMBUSTION AIR. | | | | | | 4.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | 5.CONDENSATE DRAIN TO TERMINATE A | | | MINIMUM OF 12" FROM THE BUILDING | | | STRUCTURE PER 2001 FBC 1503.4.4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-25 |
Time |
06:51 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-08-28 |
Time |
10:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-19 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-19 |
Time |
13:58 |
Sent To |
I |
|
| Notes |
|
|