| Plan Review Stops For Permit 04080325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-05-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-05-23 |
Time |
10:01 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-05-23 |
Time |
10:01 |
Sent To |
PC |
|
| Notes |
| 2005-05-23 00:00:00 | SHUTTER INSTALLATION PLAN - SAME AS ON | | | FILE FOR CONDOS; OK PER BS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-02-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-03 |
Time |
09:14 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-02-03 |
Time |
09:14 |
Sent To |
PC |
|
| Notes |
| 2005-02-03 00:00:00 | ****CORRECTIONS**** | | | HURRICANE SHUTTER INSTALLATION PLAN | | | NOT A PLAN REVIEW | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE CONTRACT WITH KLEAN K. SERVICES | | | IS TO BE AN ORIGINAL, SIGNED AND | | | NOTARIZED CONTRACT.THE LANGUAGE IN THE | | | CONTRACT IS TO BE CONSISTENT WITH THE | | | CITY'S POLICY IN REGARDS TO THE TIME | | | FRAME (HURRICANE WATCH, NOT WARNING). | | | THE LANGUAGE STATES "PRIOR TO A | | | HURRICANE WARNING"; PLEASE INCLUDE | | | LANGUAGE CONSISTENT WITH YOUR PLAN. | | | | | | 2.)THE "CONTRACT" WITH KLEAN K. | | | SERVICES PROVIDED WAS AN INVOICE, NOT A | | | CONTRACT. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-01-21 |
Time |
14:02 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2005-01-21 |
Time |
13:11 |
Sent To |
PC |
|
| Notes |
| 2005-01-21 00:00:00 | PROVISO - APPROVED SHUTTER INSTALLATION | | | PLAN REQUIRED BEFORE FRAMING | | | | | | | | | ***HOLD ON C.O. - CONTRACTOR'S | | | RESPONSIBILITY TO HAVE HOLD REMOVED | | | AFTER APPROVAL OF PLAN*** | | | | | | SAMANTHA HILL, 561-805-6724 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-13 |
Time |
11:16 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-12-13 |
Time |
08:12 |
Sent To |
|
|
| Notes |
| 2004-12-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE WINDOWS ON THE SECOND FLOOR | | | MUST BE IMPACT GLASS.PLEASE NOTE THAT | | | THE PRODUCT APPROVAL SUBMITTED IS FOR A | | | FIXED WINDOW, PLAN SHOWS OPERABLE | | | (CASEMENT) | | | | | | 2.)REGARDING THE INSTALLATION PLAN | | | FOR | | | HURRICANE PROTECTION, PLEASE SUBMIT AN | | | ORIGINAL CONTRACT WITH KLEAN K. | | | SERVICES.SERVICES ARE TO BE PERFORMED | | | BY INDIVIDUALS WITHIN PALM BEACH COUNTY | | | AS PER THE POLICY; PLEASE NOTE IN THE | | | PROPOSED PLAN. | | | | | | 3.)SEE THE SOILS REPORT; CONTINUOUS | | | FOOTINGS ARE TO BE MIN 18" BELOW GRADE. | | | F1 APPEARS TO BE BETWEEN 12-14" BELOW | | | GRADE.ALSO SEE 6.3.2 OF THE ORIGINAL | | | SOILS REPORT; WAS DESIGNER OF RECORD | | | AWARE OF THE RECOMMENDATION IN REGARDS | | | TO MONOLITHIC SLABS?PLEASE ASK DOR TO | | | READ BOTH SOILS REPORTS BEFORE | | | RESUBMITTAL. | | | | | | 4.)SOILS REPORTS ARE TO BE SEALED. | | | | | | 5.)SEE THE PREVIOUS LIST, ITEM #11. | | | RECEIPT OF AN UNSEALED LETTER | | | ADDRESSING | | | THIS MATTER FROM SHAWN STAMBAUGH, PE IS | | | ACKNOWLEDGED.IF THE FASTENING | | | CONFLICTS WITH THE TECHNICAL BULLETIN | | | FROM | | | THE MANUFACTURER, LOCAL PRODUCT | | | APPROVAL | | | (WITH CALCULATIONS) IS REQUIRED | | | FAC9B-72.PLEASE FEEL FREE TO CONTACT | | | ME TO DISCUSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-01 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-01 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2004-12-01 00:00:00 | ***SUBMITTAL*** | | | OR BK 14613/1560 | | | DEED (ORCHID RESERVE HOA) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-23 |
Time |
09:24 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-08-20 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2004-08-23 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE OWNER ON THE APPLICATION DOES | | | NOT MATCH THE OWNER IN OUR RECORDS. | | | PLEASE ADDRESS. | | | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED, FS713.13. | | | | | | 3.)PLEASE PROVIDE A SECOND COPY OF | | | THE ENERGY CALCS. | | | | | | 4.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE | | | STAMPED AND THE RECEIPT ATTACHED TO THE | | | APPLICATION. | | | | | | 5.)ADDITIONAL FEES DUE (VALUE | | | INCREASE, RADON). | | | | | | 6.)SITE PLAN, S1 DIFFERS FROM THE | | | SITE PLAN PREPARED BY THE SURVEYOR. | | | | | | 7.)SHEET C1, CALCULATIONS, GROUND | | | FLOOR LIVE LOAD IS TO COMPLY WITH | | | FBC TABLE 1604.1.YOU DECLARE AN | | | OCCUPANCY OF 7 PER SF WHICH WOULD BE | | | CONSISTENT WITH ASSEMBLY WITHOUT FIXED | | | SEATS FBC TABLE 1003.4.SHEET C1 GIVE | | | A LIVE LOAD FOR FLOORS OF 40.ASSEMBLY | | | WITHOUT FIXED SEATS REQUIRES 100, FBC | | | TABLE 1604.1.PLEASE REVISE. | | | | | | 8.)PROVIDE A SOILS INVESTIGATION | | | REPORT FBC1804.2.2. | | | | | | 9.)PLEASE PROVIDE A DIMENSION FOR | | | 'A' (ZONE 3 EDGE STRIP), ROOF ZONE | | | DIAGRAM A7. | | | | | | 10.) 6-A6 SHOWS FLOOR TRUSSES.C1 | | | REFERS TO 2ND FLOOR LIVE LOAD DESIGN | | | CRITERIA.6-A6 IS USED IN AN AREA | | | WHICH DOES NOT APPEAR TO HAVE A 2ND | | | FLOOR, AND A 2ND FLOOR PLAN HAS NOT | | | BEEN PROVIDED.AREA CALCS ARE FOR A | | | FIRST FLOOR ONLY.PLEASE CLARIFY. | | | | | | 11.)12-A6, THE FASTENING AND | | | ALLOWABLE LOADS CONFLICT WITH THE | | | TECHNICAL BULLETIN.PLEASE CLARIFY. | | | CHECK ALL CONNECTORS. | | | | | | 12.)THE PRE STORM PREPARATION PLAN | | | SUBMITTED IS FOR THE CONDOMINIUM | | | BUILDINGS. SUBMIT A PLAN FOR THE | | | CLUBHOUSE. | | | | | | 13.)THE PRODUCT APPROVAL FOR THE | | | BENCHMARK DOOR IS FOR AN OPAQUE DOOR | | | WITH SIDELITES; PRODUCT APPROVALS FOR | | | SLIDING GLASS DOORS AND HORIZONTAL | | | SLIDER WINDOWS WERE SUBMITTED; NONE ON | | | THE PLAN.PLEASE SUBMIT PRODUCT | | | APPROVALS FOR THE MULLIONS, FRENCH | | | DOORS, SINGLE HUNG WINDOWS, 3080 SOLID | | | DOORS, AND ROOF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2005-10-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-09 |
Time |
13:36 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-10-09 |
Time |
13:36 |
Sent To |
FIRE |
|
| Notes |
| 2005-10-09 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE REVISON FOR LIFE | | | SAFETY PLAN FOR CLUBHOUSE SUBMITTED, | | | HOWEVER REVSIONS SUBMITTED CONTAIN ONLY | | | ONE SET, THE SECOND SET IS A SHEET FROM | | | BLDG #5?? | | | | | | PLANS SENT TO FIRE FOR REVIEW OF LS | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | PLEASE SEE FIRE REVIEW COMMENTS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-09 |
Time |
19:24 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2005-08-09 |
Time |
19:24 |
Sent To |
|
|
| Notes |
| 2005-08-09 00:00:00 | 210.8B3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-08-04 |
Time |
08:25 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-08-04 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2005-08-04 00:00:00 | ******** UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE PREVIOUS PLANS WERE | | | NOTED ABOUT CONTINUOUS LOADS, PLEASE SEE | | | CONTINUOUS LOADS (PUMP/VAL PAK AND HEAT | | | PUMP) ON POOL SUB PANEL ARE TO BE SHOWN | | | AT 125% ON SUB PANEL. THIS LOAD WOULD | | | JUST BE CARRIED OVER TO THE LOAD ON MAIN | | | PANEL. IT IT SHOWN AT 125% ON MAIN | | | PANEL, JUST NOT SUB PANEL. | | | 215.3,680.9,230.42 ETC | | | | | | 2)NOTE: PLEASE SEE A SINK? APPEARS TO BE | | | SHOWN DIRECTLY INFRON OF PANEL "A"? | | | 110.26 | | | | | | 3)NOTE: PLEASE SEE PLANS ARE NOT SEALED | | | BY ARCHITECT OF RECORD. | | | PLEASE SEE FS 481.221 | | | | | | PLEASE ADDRESS NOTES ONE AND TWO SINCE | | | PLANS ARE COMING BACK FOR NOTE #3. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-18 |
Time |
09:56 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-18 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2005-07-18 00:00:00 | LOAD CALCS? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-07-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-08 |
Time |
13:06 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-08 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2005-07-08 00:00:00 | ********* UNSAT ********* | | | | | | 1)NOTE: PLEASE SEE 250.66 ,310.16 FOR | | | SIZING OF MIN GROUNDING ELECTRODE | | | CONDUCTOR. #2 MIN. | | | PREVIOUS REVIEW. | | | | | | 2)NOTE:PLEASE SEE ALL CONTINUOUS LOADS | | | ARE TO BE SHOWN AT 125%. | | | PLEASE SEE ONLY CONTINUOUS ARE TO BE | | | INDICATED AS "CONTINUOUS LOADS". | | | PLEASE SEE ART 100 NEC FOR DEFINITION OF | | | CONT LOADS. | | | CONTINUOUS LOAD. A LOAD WHERE THE | | | MAXIMUM CURRENT IS EXPECTED TO CONTINUE | | | FOR 3 HOURS OR MORE. | | | | | | PLEASE SEE SERVICE ETC IS BEING SHOWN AS | | | ALL BEING CONT??? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-03 |
Time |
07:40 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-01-03 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2005-01-03 00:00:00 | ******** PROVISO/REVISION *********** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEWS. | | | | | | 1)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS FROM MAINS TO | | | PANELS. | | | EQUIPMENT GRNDS REQUIRED AFTER THE FIRST | | | MEANS OF DISC. 250.24, 250.110, SIZE PER | | | 250.122 | | | | | | 2)NOTE: PLEASE SEE MIN GROUNDING | | | ELECTRODE CONDUCTOR PER 250.66 1/0. | | | | | | 3)NOTE: PLEASE SEE CIRCUITING FOR EM | | | LTS | | | PER 700.12E WITH LOCAL LIGHTING BRANCH | | | CIRCUIT. | | | | | | PLEASE REVISE THE ABOVE ALONG WITH ANY | | | OTHER REVISIONS BEFORE ROUGH ELECTRICAL | | | INSPECTION IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS, PLEASE | | | CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-18 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-11-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2004-11-18 00:00:00 | ***** UNSAT 2ND REVIEW ***** | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE: NOTE #1 OK | | | | | | 2)NOTE: NOTE #2 OK | | | | | | 3)NOTE: NOTE #3 OK | | | | | | 4)NOTE: NOTE #4 OK | | | | | | 5)NOTE: NOTE #5 NO. | | | PLEASE SEE 250.24, 250.110 FOR EQUIPMENT | | | GROUNDING AFTER THE FRIST MEANS OF | | | DISCONNECT. SIZED PER 250.122 | | | | | | 6)NOTE: NOTE #6 NO. | | | PLEASE SHOW LOAD CALCULATIONS, PLEASE | | | SHOW PER 220.3,220.10,220.11,220.13 | | | ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | | | | 7)NOTE: NOTE #7 NO. | | | PLEASE SEE EM/EXT LTS ARE NOW SHOWN ON A | | | SEPARATE CIRCUIT. PLEASE SEE 700.12E FOR | | | CIRCUITING TO LOCAL AREA LIGHTING. | | | | | | *NEW NOTE DUE TO CHANGES IN PLANS. | | | | | | 1)NOTE: PLEASE SEE GROUNDING ELECTRODE | | | DETAIL HAS NOW ADDED PARALLEL #6'S FOR | | | GROUNDING ELECTRODE CONDUCTOR. | | | | | | | | | 2)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONAL. | | | THIS IS ONLY GIVEN AS A NOTICE AT THIS | | | TIME. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | | | | | | | THIS IS NOT PERMITTED, MAY ONLY USE THE | | | #2 AS ALSO SHOWN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-18 |
Time |
10:55 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-18 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2004-08-18 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULE. | | | | | | 2)NOTE: PLEASE CORRELATE ELECTRICAL | | | PLANS W/ MECHANICAL PLANS. | | | MECH PLANS SHOW TWO A/C SYSTEMS. | | | PLEASE ALSO SEE OCP FOR A/C SYSTEMS | | | ALONG WITH LOAD CALCULATIONS. | | | | | | 3)NOTE: PLEASE CORRELATE RISER WITH | | | PLANS. PLANS SHOW TWO NEW PANELS? A&B | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | MAIN. | | | | | | 5 )NOTE: PLEASE SHOW /CLARIFY METHOD | | | OF THE EQUIPMENT GROUNDING BETWEEN | | | MAIN MEANS OF DISC AND PANELS/GUTTERS. | | | 250.110,250.24 | | | PLEASE SIZE ALL EQUIPMENT GROUNDING | | | CONDUCTORS PER 250.122 | | | | | | 6)NOTE: PLEASE SEE THIS IS CONSIDERED | | | A COMMERCIAL BLDG. | | | PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | NEEDS TO REFLECT. | | | | | | 7)NOTE: PLEASE SEE 700.12E FOR CIRCUIT-- | | | -ING OF EM/EXT LTS. | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-08-13 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-08-13 |
Time |
09:06 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-08-13 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-10-11 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-10-11 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2005-10-11 00:00:00 | DENIED: | | | | | | 1) THERE ARE TWO DIFFERENT SET OF PLANS | | | IN PACKET. ONE SET OF LIFE SAFETY PLAN | | | FOR THE CLUBHOUSE (PORTOFINO SHORES ST. | | | LUCIE COUNTY) THE OTHER SET IS | | | ELECTRICAL PLAN FOR COACH HOMES 1 IN | | | BUILDING 5. | | | | | | 2) PLEASE IDENTIFY WHAT REVISION THAT | | | YOU WANT AND RESUBMIT TO CONSTRUCTION | | | SERVICES. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-01-18 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-01-18 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-01-18 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-12-15 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-12-15 |
Time |
07:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-09-16 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-09-16 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2004-09-16 00:00:00 | 1) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND | | | CEILINGS. | | | | | | 2) BUILDING ADDRESS NOPT SHOWN ON | | | ELEVATION DRAWINGS. A MINIMUM OF AT | | | LEAST 6" HIGH NUMBERS ARE REQUIRED. | | | | | | 3) THERE APPEARS TO BE FIRE ALARM NOTES | | | ON PAGE A-8 WHICH MAY NOT BE APPLICABLE | | | TO THIS PROJECT. PLEASE ADVISE. | | | | | | 4) ALL NEW STAIRS AND RAMPS SHALL BE | | | PROVIDED WITH HANDRAILS ON BOTH SIDES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-06 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-06 |
Time |
12:09 |
Sent To |
E |
|
| Notes |
| 2005-10-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
15:14 |
Sent To |
E |
|
| Notes |
| 2005-08-08 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-03 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-03 |
Time |
16:16 |
Sent To |
E |
|
| Notes |
| 2005-08-03 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-15 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-15 |
Time |
16:13 |
Sent To |
E |
|
| Notes |
| 2005-07-15 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-06 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-06 |
Time |
10:28 |
Sent To |
E |
|
| Notes |
| 2005-07-06 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-19 |
Time |
14:39 |
Sent To |
B |
|
| Notes |
| 2005-05-19 00:00:00 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-30 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-30 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | TO "COMM BD#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-17 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-17 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2004-11-17 00:00:00 | SENT TO COMM BD#26 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
16:56 |
Sent To |
B |
|
| Notes |
| 2004-11-12 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-09-16 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-08-10 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2004-08-10 00:00:00 | TO COMM BD#11 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-16 |
Time |
14:46 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-08-30 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2004-09-16 00:00:00 | APPROVED 8-30-04 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-11 |
Time |
16:55 |
Rev Time |
0.80 |
| Received By |
kstevens |
Date |
2004-12-11 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2004-12-11 00:00:00 | PASSED/PROVISO - 606.1(4) VALVES | | | REQUIRED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-15 |
Time |
15:09 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-09-15 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2004-09-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-2 PER TABLE 403.1 A SERVICE | | | SINK IS REQUIRED. | | | 2) SUBMIT A DETAIL FOR THE URINAL TO | | | SHOW COMPLIANCE WITH SECTION 11-4.18 AND | | | ALL SUBSECTIONS. | | | 3) A WATER RISER DIAGRAM IS REQUIRED PER | | | SECTION 104.3.1.1 | | | 4) SHT A-5 THE SANT. RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN. | | | A) THE W/C'S AND LAVS IN THE HANDCAP | | | STALLS ARE REVERSED. SHOULD HAVE THE LAV | | | ON THE LEFT SIDE OF THE W/C. SECTION | | | 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2004-08-30 |
Time |
09:41 |
Rev Time |
0.50 |
| Received By |
gjoyce |
Date |
2004-08-30 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|