| Plan Review Stops For Permit 04080107 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
N |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-15 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-15 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | ONLY ONE A SHEET SUBMITTED, ALREADY | | | REVIEWED, RETURNED TO CONTRACTOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-06-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-03 |
Time |
10:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-06-01 |
Time |
16:35 |
Sent To |
PC |
|
| Notes |
| 2005-06-03 00:00:00 | REV #4, A1 2/17/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-14 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-14 |
Time |
17:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-09 |
Time |
07:36 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-12-09 |
Time |
07:36 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE SEE PREVIOUS LIST, ITEM #1. | | | SHEET A.1, KEY NOTE 14 SHOWS THE HWH IN | | | THE CEILING.PROVIDE A STRUCTURAL | | | DETAIL, INCLUDING DESIGN LOAD | | | INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-03 |
Time |
15:14 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-11-03 |
Time |
15:14 |
Sent To |
PC |
|
| Notes |
| 2004-11-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SHEET A.1, KEY NOTE 14 SHOWS THE | | | HWH IN THE CEILING.PROVIDE A | | | STRUCTURAL DETAIL, INCLUDING DESIGN | | | LOAD | | | INFORMATION. | | | | | | 2.)SHEET P-1, ITEM 14 STILL SHOWS THE | | | HWH AS UNDER THE CABINET.THIS IS | | | INCONSISTENT WITH THE LANGUAGE ON A.1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-19 |
Time |
14:53 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-08-19 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-23 |
Time |
10:03 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-06-23 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-13 |
Time |
12:21 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-06-13 |
Time |
12:21 |
Sent To |
B |
|
| Notes |
| 2005-06-13 00:00:00 | *********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE MAIN DISC ATTACHED TO | | | BUS-DUCT CHENGED FROM ORIG PLANS AS 800A | | | DOWN TO 200A'S. | | | PLEASE SEE PLANS/LOAD CALCULATIONS STILL | | | SHOW THIS AS 800A'S?? | | | | | | 2)NOTE: PLEASE VERIFY ENGINEER NOW | | | SIGNING PLANS. | | | PLEASE SEE ORIGINAL ENGINEER OF RECORD | | | IS NOT THE SAME AS INDICATED ON PLANS. | | | PLEASE SEE TITLE BLOCK NOTES ENGINEER AS | | | THE MECH ENG?? | | | FS 471.025 | | | | | | | | | NO OTHER REVISIONS INDICATED/NOTED. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-11-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-18 |
Time |
16:31 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-18 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2004-11-18 00:00:00 | PASSED ON PREVIOUS REVIEW. | | | NO NEW SHEETS FOUND. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-05 |
Time |
18:07 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-05 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2004-10-05 00:00:00 | OLD/VOIDED SHEETS NOT REMOVED FROM SETS | | | AS REQUESTED ON PREVIOUS REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-12 |
Time |
09:10 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-12 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2004-08-12 00:00:00 | *** UNSAT *** | | | | | | 1)NOTE: PLEASE SEE EM LTS SHOWN AS | | | FIXTURE TYPE "EM" APPEAR TO BE SWICTHED? | | | PLEASE SEE CIRCUIT #H10 | | | PLEASE ALSO SEE 700.12E FOR CIRCUITING | | | OF EM/EXT LTS. | | | | | | 2 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | PLEASE VERIFY LOAD ON EXISTING 800A BUS | | | DISC. | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | AS THEY MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD SHEETS MAY BE SUBMITTED | | | FOR REFERENCE ONLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-14 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-14 |
Time |
13:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-09-01 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-09-01 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2004-09-01 00:00:00 | 1) OXYGEN IS TO BE STORED AND HANDLED | | | AND USED IN ACCORDANCE WITH APPLICABLE | | | REQUIREMENTS. | | | | | | 2) OXYGEN CLOSET IS TO BE FIRE | | | SPRINKLER PROTECTED. | | | | | | 3) SEPARATE PLANS AND PERMITS | | | REQUIRED FOR FIRE ALARM AND FIRE | | | SPRINKLER SYSTEM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-20 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-20 |
Time |
08:46 |
Sent To |
E |
|
| Notes |
| 2005-06-20 00:00:00 | TO DVP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-31 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-31 |
Time |
13:35 |
Sent To |
B |
|
| Notes |
| 2005-05-31 00:00:00 | TO "SHILL" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-14 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-12-14 |
Time |
13:09 |
Sent To |
P |
|
| Notes |
| 2004-12-14 00:00:00 | TO KS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2004-11-12 00:00:00 | TO COMM BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-04 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-04 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2004-10-29 00:00:00 | TOOK OFF COMM BD AND SENT TO SH DESK FOR | | | HER REVIEW | | 2004-10-04 00:00:00 | TO COMM BD#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-09-15 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-08-03 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2004-08-03 00:00:00 | TO COMM BD#23 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-06-21 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-06-21 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-13 |
Time |
14:42 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-10-13 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-27 |
Time |
07:48 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-08-27 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2004-08-27 00:00:00 | PROVISO: | | | FAN SHUTDOWN BY DUCT SMOKE DETECTOR WITH | | | NOTIFICATION TO ALARM/STROBE IN NORMALLY | | | OCCUPPIED AREAS PER 2001 FBC(M) 606.2.1 | | | & 606.4.1. | | | | | | PLEASE PROVIDE THE MANUFACTURER | | | SUBMITTAL/INSTALLATION INSTRUCTIONS FOR | | | THE COMPRESSOR AND VACUUM WITH THE | | | THE RESUBMITTAL OF THIS PERMIT | | | APPLICATION. | | | | | | EXHAUST TERMINATIONS SHALL BE LOCATED | | | AS NOT TO RECIRCULATE BACK INTO THE | | | VENTILATION SYSTEM PER 2001 FBC(M) | | | 501.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
P |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-14 |
Time |
17:46 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-12-14 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2004-12-14 00:00:00 | SEPARATE MED-GAS PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-14 |
Time |
17:45 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-12-14 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2004-12-14 00:00:00 | SEPARATE MED-GAS PERMIT REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-10 |
Time |
07:37 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-12-10 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2004-12-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) SHT A-4 ON ONE SET IS SEALED BY NOT | | | SIGNED AND DATED. FAC 61G1-16.003 AND FS | | | 481.2055. | | | 2) SHT P-3 PLUMBING LEGEND. HAND WRITTEN | | | CHANGES TO A SIGNED AND SEALED SET OF | | | PLANS IS NOT APPROVED. EIGHER A NEW | | | SHEET SHOWING CHANGES OR THE ENGINEER | | | SIGNING AND DATING THE CHANGES ARE | | | REQUIRED. SECTION 104.2.1.3. | | | 3) REMOVE ALL VOIDED SHEETS FROM BOTH | | | SETS OF PLANS. SUBMIT ONE SET OF VOIDED | | | SHEETS SEPARATELY FOR COMPAIRISON. | | | SECTIONS 104.2.1 AND 104.2.1.3. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-14 |
Time |
17:38 |
Rev Time |
3.25 |
| Received By |
kstevens |
Date |
2004-10-14 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2004-10-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | NFPA-99C MED-GAS | | | | | | FROM PREVIOUS REVIEW: COMMENT NUMBER TO | | | REMAIN THE SAME TO AVOID CONFUSION. | | | 3) SHT A.1 SHOW CLEAR FLOOR SPACE REQUI- | | | RED BY SECTION 11-4.24.5 WHICH SHALL BE | | | PROVIDED IN FRONT OF THE SINKS TO ALLOW | | | FORWARD APPROACH. THIS IS FOR THE SINKS | | | IN THE COFFEE ROOM AND THE CONFERENCE | | | ROOM. SINKS SHALL COMPLY WITH SECTION | | | 11-4.24 AND ALL SUBSECTIONS. DETAIL DOES | | | NOT SHOW HEIGHT 11-4.24.2, KNEE CLEARAN- | | | CE 11-4.24.3, SINK DEPTH 11-4.24.4, | | | CLEAR FLOOR SPACE 11-4.24.5, (ONLY THE | | | TURNING AREA IS SHOWN), SEE FIG. 32, | | | EXPOSED PIPES AND SURFACES 11-4.24.6. | | | 6) SHT P-1 X-RAY PROCESSOR, SUBMIT MAN- | | | UFACTURE SPECIFICATION/INSTALLATION | | | SHEETS. THIS PROCESSOR MAY REQUIRE A | | | CHEMICAL NUTRALIZER AND/OR A METAL INT- | | | ERCEPTOR. IF EITHER IS REQUIRED, RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE SHALL BE | | | CONTACTED. WASTE ORD. #2938-96. TO CON- | | | TACT MR. COMPO (561) 837-4074. - NO RES- | | | PONSE NOTED TO THIS COMMENT. | | | 7) SHT P.1 UNDER COUNTER WATER HEATER | | | SHALL BE ACCESSIBLE. PLEASE SUBMIT A DE- | | | TAIOL. SECTION 501.4. - NO RESPONSE NOT- | | | ED. | | | 8) SHT P.1 INDICATE TYPE OF SINK LOCATED | | | IN THE CLOSET WITH THE VACUUM AND THE | | | AIR COMPRESSOR. SECTION 104.2.1 - NO RE- | | | SPONSE NOTED TO THIS COMMENT. | | | 11) SHT P.4 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | RISER DIAGRAM. SECTION 604.9 - WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9, (AT ICE MAKERS, DISH WASHERS, & | | | WASH MACHINES), SHALL BE LOCATED NEAR | | | THE FIXTURES IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. - SHOW | | | WATER HAMMER ARRESTORS ON RISER DIAGRAM | | | WHERE REQUIRED. | | | 12) SHT WATER FILTER SHALL COMPLY WITH | | | NSF-42, OR NSF-58 WHICH EVER APPLIES. | | | SECTION 611.1 THRU 611.4. SUBMIT MANUF. | | | SPECIFICATIONS. - NOT SUBMITTED. | | | 13) BACKFLOW REQUIRED AT X-RAY PROCESSOR | | | PER SECTION 608.16.9 - THIS IS SHOWN ON | | | THE ICE MAKER AND NOT ON THE X-RAY PRO- | | | CESSOR. | | | 15) SHT P.5 COMPRESSOR DETAIL NOW CALLS | | | FOR A 4" METAL VENT PIPE SHOWN ON SHEET | | | AC-1. INDICATE THE TERMINATION POINT FOR | | | THIS VENT PIPE. PROVIDE A DETAIL FOR THE | | | TRANSITION FROM 2" PVC TO 4" METAL DUCT. | | | SPECIFY MATERIAL OF METAL DUCT. T-FIN | | | NOT APPROVED FOR THIS APPLICATION. | | | 16) SHT P.5 VACUUM DETAIL NOT APPROVED. | | | SEE SECTION 4-5.2.1.3 LIQUIDS FROM A | | | LEVEL 3 VACUUM SYSTEM PER 4-5.2.2 SHALL | | | BE DIRECTLY CONNECTED TO THE SANITARY | | | DRAINAGE SYSTEM THROUGH AN APPROIATELY | | | TRAPPED AND VENTED DRAIN. SEE ATTACHED | | | SHEETS FROM FIRST REVIEW. | | | ------------SECOND NOTICE-------------- | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-20 |
Time |
17:23 |
Rev Time |
5.00 |
| Received By |
kstevens |
Date |
2004-08-20 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2004-08-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | NFPA-99C MED-GAS | | | FBC-2001 BUILDING | | | | | | 1) SHT A.3 FINISH SCHEDULE INDICATES THE | | | BASE IN THE TOILET ROOMS WILL BE WOOD. | | | PLEASE INDICATE HOW THIS COMPLIES WITH | | | SECTION 1204.2 WHICH STATES THE WALLS | | | AND FLOORS OF ALL PUBLIC REST ROOMS | | | SHALL BE LINED WITH NONABSORBENT MATER- | | | IAL TO A HEIGHT OF 4' ABOVE THE FLOOR. | | | 2) SHT A.1 WAS IT YOUR INTENTION NOT TO | | | HAVE A SINK IN PROCEDURE ROOM #2? NOTE | | | NO SINK SHOWN ON FLOOR PLAN. SECTION | | | 104.2.1 | | | 3) SHT A.1 SHOW CLEAR FLOOR SPACE REQUI- | | | RED BY SECTION 11-4.24.5 WHICH SHALL BE | | | PROVIDED IN FRONT OF THE SINKS TO ALLOW | | | FORWARD APPROACH. THIS IS FOR THE SINKS | | | IN THE COFFEE ROOM AND THE CONFERENCE | | | ROOMS. SINKS SHALL COMPLY WITH SECTION | | | 11-4.24 AND ALL SUBSECTIONS. SUBMIT A | | | DETAIL. | | | 4) SHTS A.1 & A.5 DETAIL 14/A5 ON SHEET | | | #1 SHOWN IN TWO DIFFERENT LOCATIONS WITH | | | DIFFEREN ELEVATIONS. PLEASE CLARIFY. | | | SECTION 104.2.1 | | | 5) SHT A.5 DETAIL #16 LABELED AS "OFFICE | | | DESK" BUT SHOWS SINK. PLEASE CLARIFY | | | SECTION 104.2.1 | | | 6) SHT P-1 X-RAY PROCESSOR, SUBMIT MAN- | | | UFACTURE SPECIFICATION/INSTALLATION | | | SHEETS. THIS PROCESSOR MAY REQUIRE A | | | CHEMICAL NUTRALIZER AND/OR A METAL INT- | | | ERCEPTOR. IF EITHER IS REQUIRED RODNEY | | | COMPO, ENVIRONMENTAL COMPLIANCE SHALL BE | | | CONTACTED. WASTE ORD. #2938. TO CONTACT | | | MR. COMPO (561) 837-4074. | | | 7) SHT P.1 UNDER COUNTER WATER HEATER | | | SHALL BE ACCESSIBLE. PLEASE SUBMIT A DE- | | | TAIL. SECTION 501.4. | | | 8) SHT P.1 INDICATE TYPE OF SINK LOCATED | | | IN THE CLOSET WITH THE VACUUM AND AIR | | | COMPRESSOR. SECTION 104.2.1 | | | 9) SHT P.3 SUBMIT A VENT ISOMETRIC WITH | | | PIPE SIZES TO COMFIRM COMPLIANCE WITH | | | TABLE 916.1 | | | 10) SHT P.3 ELECTRIC WATER HEATER DETAIL | | | THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.3.2. SUBMIT DETAIL | | | 11) SHT P.4 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | RISER DIAGRAM. SECTION 604.9 - WATER | | | HAMMER ARRESTORS REQUIRED BY SECTION | | | 604.9, (AT ICE MAKERS, DISH WASHERS, & | | | WASH MACHINES), SHALL BE LOCATED NEAR | | | THE FIXTURES, IN AN "EFFECTIVE RANGE", | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | & MANUF. INSTALL. INSTRUCTIONS. | | | 12) SHT WATER FILTER SHALL COMPLY WITH | | | NSF-42, OR NSF-58 WHICH EVER APPLIES. | | | SECTION 611.1, THRU 611.4 SUBMIT MANUF. | | | SPECIFICATIONS. | | | 13) BACKFLOW REQUIRED AT X-RAY PROCESSOR | | | PER SECTION 608.16.9 | | | 14) SEPARATE PERMIT REQUIRED FOR THE | | | MED-GAS. MED-GAS CERTIFICATION IS REQUI- | | | RED FOR THE QUALIFIER, INSTALLER, AND | | | THE BRAZER. THESE CERTIFICATIONS WITH | | | PICTURE IDENTIFICATION IS REQUIRED AT | | | THE TIME OF APPLICATION FOR PERMIT. | | | 15) SHT P.5 COMPRESSOR DETAIL CALLS FOR | | | A 2" PVC SCHED. 30 PIPE CONNECTED TO THE | | | RETURN AIR DUCT. THIS IS NOT APPROVED. | | | THE AIR INTAKE SHALL BE FROM OUTSIDE THE | | | BUILDING WHEN PRACTICAL OR SHALL BE LOC- | | | ATED WITHIN A ROOM WHERE NO CHEMICAL- | | | BASED MATERIAL IS STORED. NFPA 99C SECT- | | | ION 4-5.1.1.3(E) | | | 16) SHT P.5 VACUUM DETAIL NOT APPROVED. | | | SEE ATTACHED SHEETS (PAGE 48) FROM NFPA | | | 99C FIGURES 4-5.2.1.3(A) OR 4-5.2.1.3(B) | | | FOR APPROVED DRAINAGE. - SEE OTHER | | | SHEETS FOR DESIGN FOR VACUUM. | | | 17) SHT P.5 BACKFLOW REQUIRED FOR THE | | | WATER SOURCE TO VACUUM PER SECTION | | | 608.16.9. | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2004-12-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2004-12-15 |
Time |
13:25 |
Rev Time |
|
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|