Plan Review Details - Permit 04071384
Plan Review Stops For Permit 04071384
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-11-15 Cont ID  
Sent By alange Date 2004-11-15 Time 10:22 Rev Time 1.25
Received By alange Date 2004-11-15 Time 10:22 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-17 Cont ID  
Sent By pkrauss Date 2004-08-17 Time 10:33 Rev Time 2.50
Received By alange Date 2004-08-17 Time 14:40 Sent To  
Notes
2004-08-17 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2. PRODUCT APPROVALS REQUIRED FOR THE
 FOLLOWING, SUBMIT 2 COPIES.
 MULLIONS, TIE-DOWNS AND STRAPS, ROOFING.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 3.BATHROOM DOORS SHALL COMPLY WITH FBC
 11-11 MIN CLEAR OPENINGS SHALL BE A
 MIN. 29 CLEAR OPENING.
  
 4.SMOKE DETECTORS SHALL COMPLY WITH
 FBC 905.2.2SHOW ON PLANS.
  
 5.SUBMIT 2 COPIES OF A SOILS REPORT.
  
 6.SHOW ASSUMED PROPERTY LINE FBC504
 SHOW HOW COMPLIANCE WILL BE MADE WITH
 TABLE 600.
  
 7.SHOW ATTIC ACCESS SIZE AND LOCATION
 FBC 2309.6
  
 8.PROVIDE ENERGY CALCS FORM 600C.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 ART LANGE
 BUILDING PLAN REVIEW
 TEL: (561)805-6672
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-11-08 Cont ID  
Sent By btrobaug Date 2004-11-08 Time 17:39 Rev Time 0.00
Received By btrobaug Date 2004-11-08 Time 17:08 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-10 Cont ID  
Sent By csiegber Date 2004-08-02 Time 16:24 Rev Time 1.00
Received By btrobaug Date 2004-08-10 Time 07:04 Sent To P
Notes
2004-08-10 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE #3 CONDUCTORS FEEDING THE 200
 AMP PANEL FROM THE DISCONNECT ON THE
 RISER
 DIAGRAM ARE TOO SMALL. THEY MUST BE 2/0
 OR LARGER, SEE 210.15(B)(6), 2002 NEC.
  
 2} THE DISCONNECT LOCATED AT THE MAIN
 HOUSE (SEPERATE STRUCTURE) MUST BE
 GROUNDED PER 250.32. SHOW SAME ON PLAN.
  
 3} PANELBOARD "A" SHOWS THE BATHROOMS ON
 "AFI". PLEASE NOTE THIS IS NOT
 REQUIRED, ONLY GFI AND ARTICLE
 210.11(C)(3), SEPERATE CIRCUIT, ARE
 REQUIRED.
  
 THE FOLLOWING COMMENTS ARE FOR THE MAIN
 HOUSE.
  
 4} PLEASE SEE MISSING RECEPTACLES,
 FRONT AND/OR REAR OF DWELLING.
 210.52E
  
 5} A SMOKE DETECTOR IS REQUIRED AT THE
 STAIRWELL PER 905.2.2 2001 FBC.
  
 6} BEDROOM #2 NEEDS AN ADDED RECEPTACLE
 PER 210.52(A)(1), SEE REVIEWED PLAN.
  
 7} PLEASE SEE 8-1.4.2 NFPA-72 FOR
 DISTANCE FROM BATH REQUIREMENT RE:
 SMOKE DETECTORS.
  
 8} THE DISCONNECT LOCATION AT A/C DOES
 NOT MEET THE CLEARANCE REQUIREMENTS OF
 110.26.
  
 9} THE PANEL LOCATION WITH RESPECT TO
 THE KITCHEN COUNTER DOES NOT GIVE 36"
 CLEARANCE REQUIRED PER 110.26.
  
 THESE NOTES ARE SPECIFIC TO THE GUEST
 HOUSE.
  
 10} LIST THE BATH CIRCUIT PER
 210.11(C)(3) ON THE SCHEDULE, #12@20AMP.
  
 11} THE DISCONNECT FOR THE CONDENSING
 UNIT DOES NOT MEET 110.26 REQUIREMENTS.
  
 12} PLEASE SEE MISSING RECEPTS FOR
 FRONT AND/OR REAR OF THE UNIT PER
 210.52(E).
  
 NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2004-07-30 Cont ID  
Sent By ptjomsto Date 2004-07-30 Time 09:35 Rev Time 0.00
Received By ptjomsto Date 2004-07-30 Time 09:35 Sent To  
Notes
2004-07-30 00:00:00HISTORIC APPROVED 7/30/04 BY STILLINGS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-11-01 Cont ID  
Sent By mmclean Date 2006-07-20 Time 16:28 Rev Time 0.00
Received By csiegber Date 2004-11-01 Time 14:01 Sent To E
Notes
2004-11-01 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-02 Cont ID  
Sent By csiegber Date 2004-08-02 Time 16:24 Rev Time 0.00
Received By csiegber Date 2004-08-02 Time 16:24 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-30 Cont ID  
Sent By mmclean Date 2004-08-02 Time 15:38 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 09:56 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-11-19 Cont ID  
Sent By pkrauss Date 2004-11-19 Time 11:17 Rev Time 0.40
Received By pkrauss Date 2004-11-19 Time 10:52 Sent To  
Notes
2004-11-19 00:00:00PROVISO:
 SPOKE WITH ARCHITECT, PLANS SUBMITTED
 ARE FOR REFERENCE ONLY.REVISED PLANS
 TO BE SUBMITTED PRIOR TO INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-08-17 Cont ID  
Sent By kstevens Date 2004-08-14 Time 12:49 Rev Time 0.25
Received By pkrauss Date 2004-08-17 Time 10:30 Sent To B
Notes
2004-08-17 00:00:00DENIED:
 PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR REVIEW:
  
 1.ENERGY & MANUAL J CALCULATIONS OR
 A COMPLETED FORM 600C.
  
 2.PROVIDE EQUIPMENT SCHEDULE. INDICATE
 NEW OR EXISTING.
  
 3.PROVIDE DUCT & GRILLE SIZE, MATERIAL
 AND LAYOUT.
  
 PLEASE NOTE, PLAN SHEET A0 THE SHEET
 INDEX INDICATES PLAN SHEET M1 WHICH IS
 NOT IN THE SUBMITTAL PACKAGE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-11-09 Cont ID  
Sent By kstevens Date 2004-11-09 Time 17:45 Rev Time 0.33
Received By kstevens Date 2004-11-09 Time 17:45 Sent To B1
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-14 Cont ID  
Sent By btrobaug Date 2004-08-10 Time 10:21 Rev Time 0.50
Received By kstevens Date 2004-08-14 Time 12:49 Sent To M
Notes
2004-08-14 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SANITARY RISER DIAGRAM DO NOT MEET
 CODE REQUIREMENTS.
 A) GUEST HOUSE, WASH MACHINE SHALL DIS-
 CHARGE DOWNSTREAM OF THE WET VENT FOR
 THE BATHROOM. SECTION 909.1 - KITCHEN
 SINK ALSO SHALL DISCHARGE DOWNSTREAM OF
 WET VENT.
 B) NOT AN APPROVED FITTING AS SHOWN FOR
 FIXTURES.
 C) WASH MACHINE REQUIRES A STANDPIPE &
 A CLEANOUT 4' ABOVE THE FLOOR. SECTIONS
 1002.1/802.4 & 708.10
 (SEE EXAMPLE OF RISER DIAGRAM THAT MEETS
 CODE REQUIREMENTS FOR GUEST HOUSE. USE
 THIS EXAMPLE TO MAKE THE FOLLOWING CORR-
 ECTIONS). MAIN HOUSE RISER DOES NOT MEET
 CODE REQUIREMENTS.
 A) WASH MACHINE REQUIRES A STANDPIPE &
 A CLEANOUT 4' ABOVE THE FLOOR. SECTIONS
 1002.1/802.4 & 708.10.
 B) NOT AN APPROVED FITTING PICKING UP
 BATHROOM FIXTURES. (SEE ABOVE REFERENCED
 EXAMPLE).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-08-02 Cont ID  
Sent By csiegber Date 2004-07-30 Time 09:56 Rev Time 0.00
Received By mmclean Date 2004-08-02 Time 15:38 Sent To I
Notes
***NONE***