Plan Review Details - Permit 04071357
Plan Review Stops For Permit 04071357
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-10 Cont ID  
Sent By rbrown Date 2004-08-10 Time 15:18 Rev Time 0.00
Received By rbrown Date 2004-08-10 Time 15:18 Sent To  
Notes
2004-08-10 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) WORKING DRAWING REVIEW ONLY.NO
 PERMIT CAN BE ISSUED UNTIL THE PERMIT
 APPLICATION AND FEES ARE SUBMITTED.
  
 2) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 3) 553.37(1)(A) F.S. THE SUBMITTED PLANS
 ARE REQUIRED TO BEAR THE APPROVAL STAMP
 OF THE DEPARTMENT OF COMMUNITY AFFAIRS
 (DCA).
  
 4) FBC 11-4.8.5SHEET TR.1, THE RAMP
 HANDRAILS SHALL EXTEND 18" BEYOND THE
 SLOPED SEGMENT AT THE TOP AND BOTTOM OF
 THE RAMP.AMEND THE PLAN.THE 13'-0'
 DIMENSION AT THE BASE OF THE RAMP MAY
 NEED TO BE ADJUSTED TO ACHIEVE THIS.
  
 5) FBC 13-103.1.2BEFORE A BUILDING
 PERMIT CAN BE ISSUED, SHEET 1 OF THE
 SUBMITTED ENERGY CODE COMPLIANCE FORMS
 SHALL BE SIGNED BY THE BUILDING OWNER,
 OWNER'S ARCHITECT OR OTHER AUTHORIZED
 AGENT LEGALLY DESIGNATED BY THE OWNER.
 ALSO, SHEET 1 SHALL INCLUDE THE CORRECT
 JURISDICTION NAME (WEST PALM BEACH, FL),
 JURISDICTION CODE (604700), ADDRESS
 (5700 N FLAGLER DR), ZIP (33407) AND
 PERMIT NO. (04071357).AMEND THE ENERGY
 CODE COMPLIANCE FORMS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-10 Cont ID  
Sent By dpalmer Date 2004-08-10 Time 13:14 Rev Time 0.25
Received By dpalmer Date 2004-08-10 Time 13:14 Sent To  
Notes
2004-08-10 00:00:00************ UNSAT *******************
  
 1)NOTE: PLEASE SEE BLDG REVIEW COMMENTS
 ABOUT PLANS REQUIRED TO BE STAMPED BY
 DCA.
  
 2)NOTE: PLEASE SUBMIT ELECTRICAL RISER
 DIAGRAM FOR HOOK-UP OF TRAILERS ETC.
  
 PLEASE SEE PLANS WERE ONLY SUBMITTED
 FOR PLAN REVIEW AND NOT FOR PERMIT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2004-07-30 Cont ID  
Sent By mamini Date 2004-07-30 Time 15:27 Rev Time 0.50
Received By mamini Date 2004-07-30 Time 15:26 Sent To  
Notes
2004-07-30 00:00:00FAILED:
 1. PLEASE SHOW WATER, SEWER CONNECTIONS,
 AND LOCATION FOR METER BACKFLOWS.
 A CLEAN OUT MUST BE INSTALLED IN SEWER
 LATERAL AT BACK OF PROPERTY LINE.
 2. NOTE THAT ALL CONNECTION TO CITY
 SERVICES MUST BE APPROVED BY THE PUBLIC
 UTILITIES AND ENGINEERING PRIOR TO
 SUBMITTING TO BUILDING DEPARTMENT.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-08-18 Cont ID  
Sent By mcarsill Date 2004-08-18 Time 16:07 Rev Time 0.00
Received By mcarsill Date 2004-08-18 Time 16:07 Sent To  
Notes
2004-08-18 00:00:001) PLEASE INDICATE IN WRITING HOW
 LONG THE SALES TRAILER WILL REMAIN
 ON SITE.
  
 2) BUILDING ADDRESS IS REQUIRED. A
 MINIMUM OF 6" HIGH NUMBERS ARE
 REQUIRED.
  
 3) PLEASE INDICATE INTERIOR FINISH
 CLASSIFICATION FOR WALLS AND
 CEILINGS.
  
 4) PLEASE INDICATE LOCATIONS OF
 EMERGENCY LIGHTING AND PORTABLE
 FIRE EXTINGUISHERS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-18 Cont ID  
Sent By csiegber Date 2004-08-20 Time 11:05 Rev Time 0.00
Received By csiegber Date 2004-07-29 Time 16:51 Sent To  
Notes
2004-07-29 00:00:00TO COMM BD#19

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-08-20 Cont ID  
Sent By pkrauss Date 2004-08-20 Time 10:59 Rev Time 0.10
Received By pkrauss Date 2004-08-20 Time 10:53 Sent To  
Notes
2004-08-20 00:00:00PLANS INDICATE PACKAGE UNIT ON SHEET 3
 OF 5.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-08-18 Cont ID  
Sent By kstevens Date 2004-08-18 Time 17:34 Rev Time 0.33
Received By kstevens Date 2004-08-18 Time 17:34 Sent To  
Notes
2004-08-18 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) INDICATE LOCATION OF WATER METER,
 BACKFLOW, WATER SERVICE, SANITARY SEWER,
 AND SEWER CONNECTION. IF HOLDING TANKS
 ARE BEING USED FOR SANITARY, A PERMIT
 FROM THE HEALTH DEPT. IS REQUIRED PRIOR
 TO RESUBMITTING FOR REVIEW TO CITY WPB.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2004-08-05 Cont ID  
Sent By mmclean Date 2004-08-05 Time 16:20 Rev Time 0.00
Received By mmclean Date 2004-08-05 Time 16:20 Sent To  
Notes
2004-08-05 00:00:00DENIED, PER THE DEVELOPMENT ORDER
 ESTABLISHED BY RESOLUTION NO. 522-03,
 FOR AQUA VISTA, "THE EXISTING DOCKS
 SHALL BE REMOVED PRIOR TO ISSUANCE OF A
 BUILDING PERMIT". JOSH LONG, PLANNER
 822-1449