Plan Review Details - Permit 04071198
Plan Review Stops For Permit 04071198
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2005-07-27 Cont ID  
Sent By mjacobs Date 2005-07-27 Time 08:58 Rev Time 1.00
Received By mjacobs Date 2005-07-27 Time 08:04 Sent To PC
Notes
2005-07-27 00:00:001) EACH DRAWING SHALL HAVE THE
 ARCHITECT'S SEAL, ALONG WITH THEIR
 SIGNATURE AND THE DATE.FAC.61G1-16.003.
  
 2) A TITLE BLOCK MUST APPEAT ON ALL
 ARCHITECTURAL OR INTERIOR DESIGN
 DRAWINGS AND SPECIFICATION,WHICH SHALL
 INCLUDE 1) FIRM NAME,ADDTESS,AND
 TELEPHONE NUMBER. 2) FIRM LICENSE
 NUMBER. 3) NAME OR INDENTIFICATION OF
 PROJECT.4)DATE OREOARED.5) A SPACE FOR
 THE SIGNATURE AND DATED SEAL. 6)A SPACE
 FOR THE PRINTED NAME OF THE PERSON
 SEALING THE DOCUMENT.FAC.61G1-16.004
  
 BUILDING PLAN REVIEW
 MYRON JACOBS
 TEL: (561)805-6726
 FAX: (561)659-8026
 [email protected].
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-04-12 Cont ID  
Sent By dpalmer Date 2005-07-26 Time 17:27 Rev Time 0.25
Received By lsmith Date 2005-04-12 Time 14:12 Sent To  
Notes
2005-04-12 00:00:00REVISION:CHANGE 2 EXTERIOR PORCHES AT
 GROUND LEVEL TO BE CONCRETE. ORIGINALLY
 TO BE PAVERS LS SEE ATTACHED HIGHLIGHTED
 SURVEY LS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-09-23 Cont ID  
Sent By lsmith Date 2004-09-23 Time 10:57 Rev Time 1.00
Received By lsmith Date 2004-09-23 Time 10:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-09-20 Cont ID  
Sent By csiegber Date 2004-09-22 Time 14:35 Rev Time 1.00
Received By lsmith Date 2004-09-20 Time 08:23 Sent To  
Notes
2004-09-20 00:00:00BUILDING PLAN REVIEW FAILED
  
 1. PLANS MUST BE SIGNED & SEALED BY
 ARCHITECT. SEE SHEETS A2, A6-9.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-08-09 Cont ID  
Sent By dpalmer Date 2004-09-20 Time 08:14 Rev Time 2.00
Received By lsmith Date 2004-08-09 Time 10:18 Sent To  
Notes
2004-08-09 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. PLANS MUST BE TAKEN TO PBC AND
 IMPACT FEES PAID.THE PLANS WILL BE
 STAMPED.
 RETURN THEM WITH ACOPY OF THE PAID
 RECEIPT.
  
 2. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERK' OFFICE AND A
 COPY SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2005-08-03 Cont ID  
Sent By jleahy Date 2005-08-02 Time 13:36 Rev Time 0.00
Received By jleahy Date 2005-08-02 Time 13:36 Sent To  
Notes
2005-08-03 00:00:00RISER DIAGRAM IS NOT CORRECT.
  
 400 AMP METER MAIN CONBO WOULD NOT HAVE
 A 60 AMP PANEL FOR POOL EQUIPMENT.
  
 PANEL A2 IS THE PANEL THAT WOULD FEED
 PANELS B AND C AND THE POOL PANEL, OR
 HAVE THE POOL EQUIPMENT BREAKERS WITH
 THEM.
  
 RISER AND PANEL SCHEDULE SHOW 200 AND
 150 PANELS FOR A AND B WHICH IS IT.
  
 IF YOU SUBMIT THE SAME PLANS IN AGAIN IT
 WILL HAVE TO GO TO BUILDING FOR PLAN
 REVIEW ALSO UNLESS YOU TAKE OUT A3.
 A3 HAS NO ELECTRIC ON IT.
  
  
 QUESTIONS CALL JAKE644-7291

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2005-07-26 Cont ID  
Sent By dpalmer Date 2005-07-26 Time 17:10 Rev Time 0.50
Received By dpalmer Date 2005-07-26 Time 17:10 Sent To B
Notes
2005-07-26 00:00:00********* UNSAT **********
  
 1)NOTE: PLEASE CORRELATE RISER DIAGRAM
 AND PANEL SCHEDULES SUBMITTED.
 PLEASE SEE PANEL "A2" ON RISER INDICATES
 BRKRS ETC TO 200A SUB PANELS, HOWEVER
 BRKR/OCP IS SHOWN FOR POOL PANEL FEED.
 PLEASE SEE PANEL SCHEDULE SUBMITTED FOR
 A2, SEEMS TO BE THE POOL PANEL, PANEL
 SCHEDULE??
 PLEASE ALSO LABEL PLANS AND SHOW ALL
 PANELS AND/OR DISCONNECTS.
 PLEASE LABEL AND CORRELATE.
 215.5
  
 2)NOTE: PLEASE SEE 310.15B6 FOR MIN
 SEC'S TO BE SHOWN. PLEASE SEE 400A
 SERVICE IS SHOWN AND PROVIDED , HOWEVER
 ONLY ONE SET OF 3 2/0'S IS SHOWN FROM
 FPL HAND HOLE.?
 240.4,310.15B6 ETC.
  
 3)NOTE: PLEASE INDICATE OF ALL
 CONTINUOUS LOADS(POOL PUMP) IS SHOWN
 ALREADY @125%.
 215.3,230.42 ETC.
  
 4)NOTE: PLEASE SEE REDLINED PLANS FOR
 WHAT APPEARS TO BE A COUPLE OF MISSING
 RECEPTS REQUIRED UNDER 210.52.
  
 5)NOTE: PLEASE SEE MISSING INFORMATION
 REQUIRED ON TITLE BLOCK PER FAC
 61G1-16.004. PLEASE SEE MISSING PRINTED
 NAME AND LICENSE # FOR ARCHITECT OF
 RECORD.
 THIS IS REQUIRED OF ALL SHEETS AND FOR
 ALL TRADES WHEATHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S).
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-09-15 Cont ID  
Sent By dpalmer Date 2004-09-15 Time 08:14 Rev Time 0.50
Received By dpalmer Date 2004-09-15 Time 14:00 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-08-02 Cont ID  
Sent By csiegber Date 2004-09-01 Time 13:38 Rev Time 0.75
Received By dpalmer Date 2004-08-02 Time 16:06 Sent To M
Notes
2004-08-02 00:00:00************ UNSAT ****************
  
 1 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
 PLEASE SEE NOTE MENTIONS TO WIRE SD'S
 AHEAD OF BATH/KIT LTS. ARC FAULT
 PROECTION WOULD ALSO BE REWUIRED FOR
 THOSE BRANCH CIRCUIT(S).
  
 2 )NOTE: PLEASE SEE 220.3B4.
 PLEASE SHOW ALL RECESSED LTS BASED ON
 MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT
 BE FIGURED IN W/ 3W/PER SQ FT.
 PLEASE PROVIDE FIXTURE INFORMATION ON
 LEGEND.
  
 3)NOTE: PLEASE SEE RISER INDICATES
 EQUIPMENTS GRNDS FROM METER TO MAINS.
 PLEASE SEE 250.6 ,250.24 THIS IS NOT
 PERMITTED. EQUIPMENT GRNDS ARE ONLY
 INSTALLED AFTER THE FIRST MEANS OF
 DISCONNETC.
  
 PLANS ARE COMING BACK FOR PLUMB COMMMENT
 -S PLEASE CORRECT.
  
 ONLY NOTE: FEEDERS FROM MAINS TO PANELS
 SHOWN AS 2/0'S WHICH ARE RATED FOR 200A'
 S.
  
 ONLY NOTE: PLEASE INLCUDE ANY OTHER LV
 ON PLANS.PRE-WIRE SOUND ETC.
 IF NOT ON PLANS, SEAPRATE PLANS AND
 PERMIT WILL BE REQUIRED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2005-08-02 Cont ID  
Sent By adarroug Date 2005-08-02 Time 13:51 Rev Time 0.00
Received By adarroug Date 2005-08-02 Time 13:51 Sent To E
Notes
2005-08-02 00:00:00TO "JLEAHY"DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2005-07-21 Cont ID  
Sent By adarroug Date 2005-07-21 Time 15:55 Rev Time 0.00
Received By adarroug Date 2005-07-21 Time 15:55 Sent To E
Notes
2005-07-21 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2005-07-13 Cont ID  
Sent By adarroug Date 2005-07-13 Time 16:45 Rev Time 0.00
Received By adarroug Date 2005-07-13 Time 16:45 Sent To Z
Notes
2005-07-13 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2005-04-08 Cont ID  
Sent By adarroug Date 2005-04-08 Time 14:56 Rev Time 0.00
Received By adarroug Date 2005-04-08 Time 14:56 Sent To B
Notes
2005-04-08 00:00:00TO "LSMITH" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-03-11 Cont ID  
Sent By adarroug Date 2005-03-11 Time 08:05 Rev Time 0.00
Received By adarroug Date 2005-03-11 Time 08:05 Sent To M
Notes
2005-03-11 00:00:00TO PKRAUSS BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-01-20 Cont ID  
Sent By mjacobs Date 2005-01-20 Time 13:15 Rev Time 0.00
Received By mjacobs Date 2005-01-20 Time 13:15 Sent To M
Notes
2005-01-20 00:00:00TO "M/AC" BOX/REV.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-11-01 Cont ID  
Sent By csiegber Date 2004-11-01 Time 12:09 Rev Time 0.00
Received By csiegber Date 2004-11-01 Time 12:09 Sent To P
Notes
2004-11-01 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-09-22 Cont ID  
Sent By csiegber Date 2004-09-22 Time 14:35 Rev Time 0.00
Received By csiegber Date 2004-09-22 Time 14:35 Sent To B
Notes
2004-09-22 00:00:00TO LS DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-09-01 Cont ID  
Sent By csiegber Date 2004-09-01 Time 13:38 Rev Time 0.00
Received By csiegber Date 2004-09-01 Time 13:38 Sent To E
Notes
2004-09-01 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-31 Cont ID  
Sent By csiegber Date 2004-08-31 Time 14:08 Rev Time 0.00
Received By csiegber Date 2004-08-31 Time 14:08 Sent To E
Notes
2004-08-31 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-09 Cont ID  
Sent By mmclean Date 2004-07-29 Time 09:39 Rev Time 0.00
Received By lsmith Date 2004-07-28 Time 11:43 Sent To  
Notes
2004-07-29 00:00:00TO SFD RACK/E
2004-07-28 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2005-03-17 Time   Rev Time 0.00
Received By hmoser Date 2005-03-17 Time 13:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-01-25 Cont ID  
Sent By pkrauss Date 2005-01-25 Time 10:26 Rev Time 0.35
Received By pkrauss Date 2005-01-25 Time 09:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-08-07 Cont ID  
Sent By dpalmer Date 2004-08-02 Time 16:06 Rev Time 0.50
Received By rregueir Date 2004-08-07 Time 11:09 Sent To  
Notes
2004-08-07 00:00:00----------------PROVISO-----------------
 1)COMBUSTION AIR REQUIRED FOR GAS DRYER
 IN CONFINED SPACE PER FBC,FG 304
 BASED ON 50 CU FT PER 1000 BTUH
 2)AUX. DRAIN PANS REQUIRED UNDER AHUS
 PER FBC,M 307.4
 3)R/A IN BEDROOMS 3,4,5 TOO SMALL PER
 FBC,M 601.4
  
 ANY QUESTIONS PLEASE CALL:
 RONALD J REGUEIRO
 561-805-6734

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-11-06 Cont ID  
Sent By pschmitz Date 2004-11-06 Time 08:02 Rev Time 0.00
Received By pschmitz Date 2004-11-06 Time 08:01 Sent To  
Notes
2004-11-06 00:00:00REVISION: ADD ISLAND SINK.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-09-18 Cont ID  
Sent By jleech Date 2004-09-18 Time 09:33 Rev Time 0.75
Received By jleech Date 2004-09-18 Time 09:33 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-31 Cont ID  
Sent By jleech Date 2004-07-31 Time 08:11 Rev Time 0.75
Received By jleech Date 2004-07-31 Time 08:11 Sent To E
Notes
2004-07-31 00:00:00RISER DIAGRAM NOT TO CODE.
 BATH 2,3,AND CABANA SHOWERS ARE NOT
 VENTED.
 MASTER BATH TUB AND SHR ARE NOT VENTED,
 AND MISSING A W/C.
 BATH 4 AND 5 TUBS ARE SHOWN ON FLOOR
 PLAN SHOWERS ARE SHOWN ON RISER DIAGRAM.
 L/T AND W/M ARE UNVENTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2005-07-21 Cont ID  
Sent By mmclean Date 2005-07-21 Time 15:44 Rev Time 0.00
Received By mmclean Date 2005-07-21 Time 15:44 Sent To PC
Notes
2005-07-21 00:00:00APPROVING PAVERS FOR 20FT ACCESS EASMENT
 (REVISION). GIVEN TO WANDA.

Review Stop Z ZONING
Rev No 2 Status P Date 2005-04-07 Cont ID  
Sent By mmclean Date 2005-04-07 Time 15:54 Rev Time 0.00
Received By mmclean Date 2005-04-07 Time 15:54 Sent To I
Notes
2005-04-07 00:00:00APPROVING REVISION OF COV. PATIO FROM
 BRICK TO CONCRETE.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-29 Cont ID  
Sent By mmclean Date 2004-07-29 Time 09:39 Rev Time 0.00
Received By mmclean Date 2004-07-29 Time 09:39 Sent To I
Notes
2004-07-29 00:00:00MUST PULL SEPARATE PERMIT FOR POOL &
 FENCE.