| Plan Review Stops For Permit 04071198 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-07-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-07-27 |
Time |
08:58 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2005-07-27 |
Time |
08:04 |
Sent To |
PC |
|
| Notes |
| 2005-07-27 00:00:00 | 1) EACH DRAWING SHALL HAVE THE | | | ARCHITECT'S SEAL, ALONG WITH THEIR | | | SIGNATURE AND THE DATE.FAC.61G1-16.003. | | | | | | 2) A TITLE BLOCK MUST APPEAT ON ALL | | | ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION,WHICH SHALL | | | INCLUDE 1) FIRM NAME,ADDTESS,AND | | | TELEPHONE NUMBER. 2) FIRM LICENSE | | | NUMBER. 3) NAME OR INDENTIFICATION OF | | | PROJECT.4)DATE OREOARED.5) A SPACE FOR | | | THE SIGNATURE AND DATED SEAL. 6)A SPACE | | | FOR THE PRINTED NAME OF THE PERSON | | | SEALING THE DOCUMENT.FAC.61G1-16.004 | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | [email protected]. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-26 |
Time |
17:27 |
Rev Time |
0.25 |
| Received By |
lsmith |
Date |
2005-04-12 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2005-04-12 00:00:00 | REVISION:CHANGE 2 EXTERIOR PORCHES AT | | | GROUND LEVEL TO BE CONCRETE. ORIGINALLY | | | TO BE PAVERS LS SEE ATTACHED HIGHLIGHTED | | | SURVEY LS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-09-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-09-23 |
Time |
10:57 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-09-23 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:35 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-09-20 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2004-09-20 00:00:00 | BUILDING PLAN REVIEW FAILED | | | | | | 1. PLANS MUST BE SIGNED & SEALED BY | | | ARCHITECT. SEE SHEETS A2, A6-9. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-20 |
Time |
08:14 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-08-09 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2004-08-09 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. PLANS MUST BE TAKEN TO PBC AND | | | IMPACT FEES PAID.THE PLANS WILL BE | | | STAMPED. | | | RETURN THEM WITH ACOPY OF THE PAID | | | RECEIPT. | | | | | | 2. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK' OFFICE AND A | | | COPY SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-08-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-08-02 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2005-08-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2005-08-03 00:00:00 | RISER DIAGRAM IS NOT CORRECT. | | | | | | 400 AMP METER MAIN CONBO WOULD NOT HAVE | | | A 60 AMP PANEL FOR POOL EQUIPMENT. | | | | | | PANEL A2 IS THE PANEL THAT WOULD FEED | | | PANELS B AND C AND THE POOL PANEL, OR | | | HAVE THE POOL EQUIPMENT BREAKERS WITH | | | THEM. | | | | | | RISER AND PANEL SCHEDULE SHOW 200 AND | | | 150 PANELS FOR A AND B WHICH IS IT. | | | | | | IF YOU SUBMIT THE SAME PLANS IN AGAIN IT | | | WILL HAVE TO GO TO BUILDING FOR PLAN | | | REVIEW ALSO UNLESS YOU TAKE OUT A3. | | | A3 HAS NO ELECTRIC ON IT. | | | | | | | | | QUESTIONS CALL JAKE644-7291 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2005-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-07-26 |
Time |
17:10 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-07-26 |
Time |
17:10 |
Sent To |
B |
|
| Notes |
| 2005-07-26 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANEL SCHEDULES SUBMITTED. | | | PLEASE SEE PANEL "A2" ON RISER INDICATES | | | BRKRS ETC TO 200A SUB PANELS, HOWEVER | | | BRKR/OCP IS SHOWN FOR POOL PANEL FEED. | | | PLEASE SEE PANEL SCHEDULE SUBMITTED FOR | | | A2, SEEMS TO BE THE POOL PANEL, PANEL | | | SCHEDULE?? | | | PLEASE ALSO LABEL PLANS AND SHOW ALL | | | PANELS AND/OR DISCONNECTS. | | | PLEASE LABEL AND CORRELATE. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 310.15B6 FOR MIN | | | SEC'S TO BE SHOWN. PLEASE SEE 400A | | | SERVICE IS SHOWN AND PROVIDED , HOWEVER | | | ONLY ONE SET OF 3 2/0'S IS SHOWN FROM | | | FPL HAND HOLE.? | | | 240.4,310.15B6 ETC. | | | | | | 3)NOTE: PLEASE INDICATE OF ALL | | | CONTINUOUS LOADS(POOL PUMP) IS SHOWN | | | ALREADY @125%. | | | 215.3,230.42 ETC. | | | | | | 4)NOTE: PLEASE SEE REDLINED PLANS FOR | | | WHAT APPEARS TO BE A COUPLE OF MISSING | | | RECEPTS REQUIRED UNDER 210.52. | | | | | | 5)NOTE: PLEASE SEE MISSING INFORMATION | | | REQUIRED ON TITLE BLOCK PER FAC | | | 61G1-16.004. PLEASE SEE MISSING PRINTED | | | NAME AND LICENSE # FOR ARCHITECT OF | | | RECORD. | | | THIS IS REQUIRED OF ALL SHEETS AND FOR | | | ALL TRADES WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-15 |
Time |
08:14 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-09-15 |
Time |
14:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-01 |
Time |
13:38 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
16:06 |
Sent To |
M |
|
| Notes |
| 2004-08-02 00:00:00 | ************ UNSAT **************** | | | | | | 1 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | PLEASE SEE NOTE MENTIONS TO WIRE SD'S | | | AHEAD OF BATH/KIT LTS. ARC FAULT | | | PROECTION WOULD ALSO BE REWUIRED FOR | | | THOSE BRANCH CIRCUIT(S). | | | | | | 2 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 3)NOTE: PLEASE SEE RISER INDICATES | | | EQUIPMENTS GRNDS FROM METER TO MAINS. | | | PLEASE SEE 250.6 ,250.24 THIS IS NOT | | | PERMITTED. EQUIPMENT GRNDS ARE ONLY | | | INSTALLED AFTER THE FIRST MEANS OF | | | DISCONNETC. | | | | | | PLANS ARE COMING BACK FOR PLUMB COMMMENT | | | -S PLEASE CORRECT. | | | | | | ONLY NOTE: FEEDERS FROM MAINS TO PANELS | | | SHOWN AS 2/0'S WHICH ARE RATED FOR 200A' | | | S. | | | | | | ONLY NOTE: PLEASE INLCUDE ANY OTHER LV | | | ON PLANS.PRE-WIRE SOUND ETC. | | | IF NOT ON PLANS, SEAPRATE PLANS AND | | | PERMIT WILL BE REQUIRED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-02 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-02 |
Time |
13:51 |
Sent To |
E |
|
| Notes |
| 2005-08-02 00:00:00 | TO "JLEAHY"DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-21 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-21 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2005-07-21 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-07-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-13 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-13 |
Time |
16:45 |
Sent To |
Z |
|
| Notes |
| 2005-07-13 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-08 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-08 |
Time |
14:56 |
Sent To |
B |
|
| Notes |
| 2005-04-08 00:00:00 | TO "LSMITH" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-11 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-11 |
Time |
08:05 |
Sent To |
M |
|
| Notes |
| 2005-03-11 00:00:00 | TO PKRAUSS BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-20 |
Time |
13:15 |
Sent To |
M |
|
| Notes |
| 2005-01-20 00:00:00 | TO "M/AC" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-01 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-01 |
Time |
12:09 |
Sent To |
P |
|
| Notes |
| 2004-11-01 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2004-09-22 00:00:00 | TO LS DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-01 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-01 |
Time |
13:38 |
Sent To |
E |
|
| Notes |
| 2004-09-01 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-31 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-31 |
Time |
14:08 |
Sent To |
E |
|
| Notes |
| 2004-08-31 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-29 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-07-28 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | TO SFD RACK/E | | 2004-07-28 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-17 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-25 |
Time |
10:26 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2005-01-25 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-02 |
Time |
16:06 |
Rev Time |
0.50 |
| Received By |
rregueir |
Date |
2004-08-07 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2004-08-07 00:00:00 | ----------------PROVISO----------------- | | | 1)COMBUSTION AIR REQUIRED FOR GAS DRYER | | | IN CONFINED SPACE PER FBC,FG 304 | | | BASED ON 50 CU FT PER 1000 BTUH | | | 2)AUX. DRAIN PANS REQUIRED UNDER AHUS | | | PER FBC,M 307.4 | | | 3)R/A IN BEDROOMS 3,4,5 TOO SMALL PER | | | FBC,M 601.4 | | | | | | ANY QUESTIONS PLEASE CALL: | | | RONALD J REGUEIRO | | | 561-805-6734 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-11-06 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-11-06 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2004-11-06 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2004-11-06 00:00:00 | REVISION: ADD ISLAND SINK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-09-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-09-18 |
Time |
09:33 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2004-09-18 |
Time |
09:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-31 |
Time |
08:11 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2004-07-31 |
Time |
08:11 |
Sent To |
E |
|
| Notes |
| 2004-07-31 00:00:00 | RISER DIAGRAM NOT TO CODE. | | | BATH 2,3,AND CABANA SHOWERS ARE NOT | | | VENTED. | | | MASTER BATH TUB AND SHR ARE NOT VENTED, | | | AND MISSING A W/C. | | | BATH 4 AND 5 TUBS ARE SHOWN ON FLOOR | | | PLAN SHOWERS ARE SHOWN ON RISER DIAGRAM. | | | L/T AND W/M ARE UNVENTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-07-21 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-07-21 |
Time |
15:44 |
Sent To |
PC |
|
| Notes |
| 2005-07-21 00:00:00 | APPROVING PAVERS FOR 20FT ACCESS EASMENT | | | (REVISION). GIVEN TO WANDA. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-04-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-04-07 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-04-07 |
Time |
15:54 |
Sent To |
I |
|
| Notes |
| 2005-04-07 00:00:00 | APPROVING REVISION OF COV. PATIO FROM | | | BRICK TO CONCRETE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-29 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-29 |
Time |
09:39 |
Sent To |
I |
|
| Notes |
| 2004-07-29 00:00:00 | MUST PULL SEPARATE PERMIT FOR POOL & | | | FENCE. |
|
|