| Plan Review Stops For Permit 04071171 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-24 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-24 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2005-03-24 00:00:00 | REVISED SHEETS FOR ROOF A6,A7,A8 & S4 | | | ARE OK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-11 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-11 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2005-03-11 00:00:00 | STRUCTURE HAS A MEAN ROOF HEIGHT OF MORE | | | THAN 33 FEET. ASPHALT SHINGLES WERE | | | APPROVED FOR USE BY NEIL MELICK, B.O. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-07 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-07 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2005-03-07 00:00:00 | DENIED | | | | | | 1) SUBMIT COMPLETE TESTING REPORTS (WITH | | | ANY LIMITATIONS) AND INSTALLATION | | | INSTRUCTIONS AND DRAWINGS FOR THE | | | ASPHALT ROOF SHINGLES. NOTE: STRUCTURE | | | EXCEEDS 33 FEET. | | | | | | 2) SUBMIT THE NOA OR EVALUATION REPORT | | | FROM THE STATE PRODUCT APPROVAL WEBSITE | | | FOR THE GLASS BLOCK. IT IS MISSING FROM | | | THE SUBMITTAL. | | | | | | 3) THE SIMPSON CONNECTOR SPECIFIED ON S4 | | | FOR MARK (J) IN THE SCHEDULE AS HDSA IS | | | A TYPO AND SHOULD BE HD5A. PLEASE | | | CORRECT. | | | | | | 4) THE CONNECTOR SPECIFIED AT THE | | | EXTERIOR WALL FOR THE MG1 GIRDER TRUSSES | | | IS NOT ADEQUATE TO RESIST THE UPLIFT | | | LISTED IN THE TRUSS DRAWINGS. | | | | | | 5) PLEASE CLARIFY THAT DETAIL 10 ON S7 | | | IS TYPICAL FOR EACH END OF ALL THE GR2 | | | GIRDERS AND ONE END OF THE GR1 GIRDERS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-10 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2004-12-10 00:00:00 | DENIED | | | | | | 1) THE OWNER/AGENT IS REQUIRED TIO SIGN | | | THE ENERGY CALC. FORMS. THE ENERGY | | | CALCS. DO NOT SPECIFY THE 2X6 WOOD FRAME | | | EXTERIOR WALLS WITH R-19 INSULATION. THE | | | PLANS SPECIFY R-30 CEILING INSULATION | | | AND THE ENERGY CALCS. LISTS R-19. PLEASE | | | CORRECT. | | | | | | 2) FBC 2504.2.1 REQUIRES EXTERIOR | | | APPLICATIONS OF PORTLAND CEMENT PLASTER | | | TO COMPLY WITH ASTM C 926. THIS STANDARD | | | REQUIRES PLASTER OVER METAL BASE TO BE | | | 5/8" THICK ON HORIZONTAL APPLICATIONS | | | AND 7/8" FOR VERTICAL APPLICATIONS. | | | | | | 3) MEAN ROOF HEIGHT FOR THE STRUCTURE IS | | | 38'-5". SUBMIT ENGINEERED CALCULATIONS | | | FOR THE ROOF SHEATHING FASTENING | | | REQUIREMENTS. | | | | | | 4) PROVIDE CAP DETAILS FOR THE WOOD | | | COLUMN (WP-1) AND THE STEEL COLUMN | | | (SC-1). | | | | | | 5) SECT.5 ON S7 WHICH SHOWS A 6X6 WD. | | | POST, HOWEVER, NO ID TAG IS ON THE PLAN | | | FOR THIS SECTION. PLEASE CLARIFY. | | | | | | 6) SUBMIT PRODUCT APPROVALS FOR ASPHALT | | | ROOF SHINGLES THAT WERE TESTED TO ASTM D | | | 3161 (MODIFIED TO 110 MPH) OR PA 107 AND | | | ARE NOT LIMITED TO A 33'MRH. | | | | | | 7) THE DOOR SCHEDULE FOR UNIT 2 & 2R | | | DOES NOT LIST THE 16'WIDE OVERHEAD | | | GARAGE DOOR OR THEIR REQUIRED DESIGN | | | PRESSURES. | | | | | | 8) THE NOA/EVALUATION REPORT FOR THE | | | GLASS BLOCK IS MISSING. | | | | | | 9) A PRODUCT APPROVAL FOR FIXED GLASS | | | WINDOWS WAS SUBMITTED AND THERE AREN'T | | | ANY SPECIFIED ON THE PLANS. PLEASE | | | CLARIFY. | | | | | | 10) THE TRUSS LAYOUTS AND DRAWINGS ARE | | | REQUIRED TO HAVE THE ORIGINAL WET | | | SIGNATURE OF THE TRUSS ENGINEER PER FAC | | | 61G15-23.002. | | | | | | NOTE: THE PRODUCT APPROVALS FOR THE | | | 6-UNIT "B" ELEVATION WERE USED FOR THIS | | | REVIEW. SUBMIT COMPLETE SETS FOR EACH | | | MASTER PERMIT. | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-07-29 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-07-29 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | SEE PLAN REVIEW # 04021360 FOR COMMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-24 |
Time |
17:05 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-01-24 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-30 |
Time |
07:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-30 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE RECEPT ON 2' OF WALL | | | IN BEDRM #2, APPEARS TO BE "IN" A WALL? | | | 210.52 | | | | | | 2)NOTE: IT HAS COME TO OUR ATTENTION | | | THE | | | SEC'S ARE ACTUALLY BEING INSTALLED BY | | | THE ELECTRICAL CONTRACTOR AND NOT FPL> | | | IF INDEED THIS WILL BE, THEN SEC'S ARE | | | TO BE SHOWN ON RISER DIAGRAM AND MUST | | | MEET 310.16 2002 NEC. | | | | | | 3)NOTE: PLEASE ALSO SEE 250.66 FOR | | | SIZING OF GROUNDING ELECTRODE | | | CONDUCTOR. | | | THIS MAY NEED TO BE CORRECTED ON RISER | | | DUE TO SEC'S CHANGES? | | | SHOWN AS 1/0 NOW, WHICH IS NOT LARGE | | | ENOUGH. | | | PLEASE ADJUST. | | | | | | 4)NOTE: PLEASE SEE TITLE BLOCKS FOR | | | ELECTRICAL AND MECHANICAL SHEETS. | | | THESE STILL INDICATE A "FIRM". | | | PLEASE ADJUST TITLE BLOCK OR INCLUDE | | | LICENSE # AS REQUIRED UNDER FAC | | | 61G15-23.002, FS 471.023. | | | PLEASE SEE THIS IS REQUIRED OF OTHER | | | POSSIBLE SHEETS WHEATHER OR NOT COMMENT | | | OS MADE BY OTHER REVIEWER(S). | | | | | | 5)NOTE: PLEASE SEE PLANS STILL INDICATE | | | A MAIN DISC AND 8-METERS. THIS COMMENT | | | WAS GIVEN ONPREVIOUS REVIEW UNDER | | | #04021360 THIS DOE NOT CORRELATE WITH | | | RISER. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-11-30 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-11-30 |
Time |
09:03 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-11-30 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2004-11-30 00:00:00 | PASSED: | | | | | | 1.SEE # 03101412 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-03-02 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-03-02 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-12-21 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-12-21 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-12-21 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | SEE PERMIT # 04021360 FOR REVIEW NOTES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-20 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2005-01-20 00:00:00 | TO "COMM BD#43/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-11-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-29 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-29 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2004-11-29 00:00:00 | SENT TO COMM BD#54 | | | PRODUCT APPROVALS ARE ON THE S.F.R. RACK | | | ABOVE ELEC. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-12-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-04 |
Time |
07:58 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-12-04 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2004-12-04 00:00:00 | DENIED: 6 UNITS/A ELEVATION | | | SEE COMMENT #4 BY DEWEY PALMER, | | | ELECTRICAL PLAN REVIEW.PLANS ARE | | | OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-03-11 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-11 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-16 |
Time |
18:56 |
Sent To |
|
|
| Notes |
| 2005-03-11 00:00:00 | OK PER KEN STEVENS ON 2-17-05 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-13 |
Time |
15:00 |
Rev Time |
0.66 |
| Received By |
kstevens |
Date |
2004-12-13 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | SEE PERMIT #04021360 FOR REVIEW COMMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-02-02 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-02-02 |
Time |
12:00 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2005-02-02 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2004-12-13 |
Time |
15:30 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2004-12-13 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2004-12-13 00:00:00 | BUILDING EXCEEDS MAXIMUM TOWNHOUSE | | | HEIGHT OF 35 FEET PER SECTION | | | 94-307(G)(6)C OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | FALSE CHIMNEYS EXCEED MAXIMUM ALLOWED | | | HEIGHT OF 38.5 FEET PER SECTION | | | 94-304(A) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-09 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | SEE PERMIT #04021360 FOR REVIEW NOTES |
|
|