| Plan Review Stops For Permit 04071169 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-04-22 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-04-22 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-23 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-23 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2005-03-23 00:00:00 | DENIED | | | | | | 1) TRUSS CONNECTOR MARK 'J' ON SHEET S4 | | | CALLS FOR (2) HDSA. IS THIS SUPPOSE TO | | | BE A SIMPSON HD5A CONNECTOR? A TWO | | | MEMBER TRUSS IS SPECIFIED IN THE | | | CONNECTOR SCHEDULE AT THIS LOCATION, | | | HOWEVER IT IS A 4 MEMBER TRUSS. HOW WAS | | | THE UPLIFT DETERMINED FOR THESE | | | CONNECTORS. THE SIMPSON CATALOG LISTS A | | | TENSION LOAD OF 3980# FOR ONE CONNECTOR. | | | | | | 2) THE MG1 TRUSSES HAVE AN -1181# AT THE | | | EXTERIOR WALLS. THIS EXCEEDS THE | | | ALLOWABLE UPLIFT OF 990# OF THE SIMPSON | | | H10 CONNECTORS THAT ARE SPECIFIED. | | | | | | 3) THE GLASS BLOCK PRODUCT APPROVAL | | | SUBMITTAL IS MISSING THE MIAMI-DADE NOA | | | WITH THE INSTALLATION INSTRUCTIONS. | | | | | | 4) THE PRODUCT APPROVAL SUBMITTAL FOR | | | THE ASPHALT SINGLES IS MISSING THE | | | INSTALLATION INSTRUCTIONS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
17:47 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-02-24 |
Time |
17:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-02-14 |
Time |
09:23 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-02-14 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | PASSED: | | | | | | 1. SEE PERMIT # 04010006 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-22 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-22 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | 1) PLEASE BE ADVISED THAT ALL LIFE | | | SAFETY MUST COMPLY WITH NFPA 101, 2003 | | | EDITION. | | | | | | 2) PLANS DON'T SHOW A SMOKE DETECTOR IN | | | THE MASTER BEDROOM IN UNIT 1448. | | | | | | 3) PLEASE BE ADVISED THAT THE FIRE ALARM | | | SHALL BE MONITORED BY A UL LISTED | | | CENTRAL STATION SERVICE. | | | | | | | | | MIKE WENNERGREN, ACTING CAPTAIN | | | WPBFR(561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-27 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-27 |
Time |
11:20 |
Sent To |
B |
|
| Notes |
| 2005-04-27 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-01 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-01 |
Time |
14:21 |
Sent To |
B |
|
| Notes |
| 2005-04-01 00:00:00 | TO "RMCDOUGAL" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-14 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-14 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2005-02-14 00:00:00 | TO "COMM" BD #60 ON RACK, 1 ROLL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-03-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-03-12 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
10:18 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-08-26 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2004-08-26 00:00:00 | PROVIDE MANUFACTURER INSTALLATION | | | INSTRUCTIONS FOR THE CEILING RADIATION | | | DAMPERS ON THE JOBSITE AT THE TIME OF | | | INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-04-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-04-22 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-04-22 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2005-04-22 00:00:00 | PASSED BY K.STEVENS ON 3/11/05 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2005-02-14 |
Time |
14:48 |
Rev Time |
0.20 |
| Received By |
eschneid |
Date |
2005-02-14 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|