Plan Review Details - Permit 04070881
Plan Review Stops For Permit 04070881
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-07-26 Cont ID  
Sent By lsmith Date 2004-07-26 Time 14:46 Rev Time 2.00
Received By lsmith Date 2004-07-26 Time 14:46 Sent To  
Notes
2004-07-26 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 1. SUBMIT MFGRS. SHEETS ON THE FIREPLACE
 BEFORE INSTALLATION.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-04-20 Cont ID  
Sent By btrobaug Date 2005-04-20 Time 10:38 Rev Time 0.50
Received By btrobaug Date 2005-04-20 Time 10:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-09 Cont ID  
Sent By btrobaug Date 2004-08-09 Time 13:14 Rev Time 0.75
Received By btrobaug Date 2004-08-09 Time 12:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-07-22 Cont ID  
Sent By csiegber Date 2004-08-05 Time 13:52 Rev Time 0.50
Received By btrobaug Date 2004-07-22 Time 14:55 Sent To M
Notes
2004-07-22 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE #6 GROUND BETWEEN THE DISCONNECTS
 IS IN VIOLATION OF 250.6.
  
 2} PLEASE LIST ALL THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.11C3
  
 3} THE STEAM SHOWER IS NOT IN THE LOAD
 CALCULATION.
  
 4} PLEASE PROVIDE PANEL SCHEDULES FOR
 ALL PANELS SO THAT COMPLIANCE OF BRANCH
 CIRCUITS CAN BE DETERMINED.
  
 5} THE DISCONNECTS BEHIND THE CONDENSING
 UNITS DO NOT COMPLY WITH CLEARANCE
 REQUIREMENTS OF 110.26.
  
 6} SMOKE DETECTORS ARE REQUIRED PER 8-1.
 4.1.6.2 NFPA-72, AND 905.2 FBC..
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-04-19 Cont ID  
Sent By adarroug Date 2005-04-19 Time 13:32 Rev Time 0.00
Received By adarroug Date 2005-04-19 Time 13:32 Sent To E
Notes
2005-04-19 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-05 Cont ID  
Sent By csiegber Date 2004-08-05 Time 13:52 Rev Time 0.00
Received By csiegber Date 2004-08-05 Time 13:52 Sent To E
Notes
2004-08-05 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-08-03 Cont ID  
Sent By mmclean Date 2004-07-21 Time 14:54 Rev Time 0.00
Received By pkrauss Date 2004-07-21 Time 11:50 Sent To  
Notes
2004-07-22 00:00:00TO SFD RACK/E
2004-07-21 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-08-03 Cont ID  
Sent By jleech Date 2004-07-27 Time 17:25 Rev Time 0.34
Received By pkrauss Date 2004-08-03 Time 09:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-07-27 Cont ID  
Sent By jleech Date 2004-07-27 Time 17:25 Rev Time 0.33
Received By jleech Date 2004-07-27 Time 17:25 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-21 Cont ID  
Sent By mmclean Date 2004-07-21 Time 14:54 Rev Time 0.00
Received By mmclean Date 2004-07-21 Time 14:54 Sent To I
Notes
2004-07-21 00:00:00MUST PULL A SEPARATE PERMIT FOR POOL