| Plan Review Stops For Permit 04070881 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-26 |
Time |
14:46 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-07-26 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. SUBMIT MFGRS. SHEETS ON THE FIREPLACE | | | BEFORE INSTALLATION. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-04-20 |
Time |
10:38 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-04-20 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-09 |
Time |
13:14 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-08-09 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
13:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-07-22 |
Time |
14:55 |
Sent To |
M |
|
| Notes |
| 2004-07-22 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE #6 GROUND BETWEEN THE DISCONNECTS | | | IS IN VIOLATION OF 250.6. | | | | | | 2} PLEASE LIST ALL THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.11C3 | | | | | | 3} THE STEAM SHOWER IS NOT IN THE LOAD | | | CALCULATION. | | | | | | 4} PLEASE PROVIDE PANEL SCHEDULES FOR | | | ALL PANELS SO THAT COMPLIANCE OF BRANCH | | | CIRCUITS CAN BE DETERMINED. | | | | | | 5} THE DISCONNECTS BEHIND THE CONDENSING | | | UNITS DO NOT COMPLY WITH CLEARANCE | | | REQUIREMENTS OF 110.26. | | | | | | 6} SMOKE DETECTORS ARE REQUIRED PER 8-1. | | | 4.1.6.2 NFPA-72, AND 905.2 FBC.. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-19 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-19 |
Time |
13:32 |
Sent To |
E |
|
| Notes |
| 2005-04-19 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-05 |
Time |
13:52 |
Sent To |
E |
|
| Notes |
| 2004-08-05 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-07-21 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | TO SFD RACK/E | | 2004-07-21 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
17:25 |
Rev Time |
0.34 |
| Received By |
pkrauss |
Date |
2004-08-03 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
17:25 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-07-27 |
Time |
17:25 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-21 |
Time |
14:54 |
Sent To |
I |
|
| Notes |
| 2004-07-21 00:00:00 | MUST PULL A SEPARATE PERMIT FOR POOL |
|
|