| Plan Review Stops For Permit 04070862 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-01-13 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2005-01-13 |
Time |
15:37 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-01-13 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2005-01-13 00:00:00 | RESTAMP PHOTO COPY OF ORIGINAL LOST ON | | | JOB. LS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-31 |
Time |
15:06 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-08-31 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-31 |
Time |
14:43 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-07-26 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2004-07-26 00:00:00 | BUIDING PLAN REVIEW: FAILED | | | | | | 1. SEE ELECTRICAL NOTE #1 REGARDING | | | TITLE BLOCK. | | | | | | 2. A & P CUSTOM WINDOW MFG., INC IS NOT | | | REGISTERED WITH THE STATE OF FLORIDA FIR | | | THE SERIES "3000" FIXED WINDOW.SUBMIT | | | A SITE SPECIFIC APPLICATION OR SELECT A | | | NOTHER CONTRACTOR.A SITE SPECIFIC FORM | | | IS ATTACHED FOR YOUR USE. | | | | | | ANY QUESTIONSPLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-05-24 |
Time |
10:47 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-05-24 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-31 |
Time |
14:43 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-31 |
Time |
14:43 |
Sent To |
B |
|
| Notes |
| 2004-08-31 00:00:00 | NOTE FOR SD BACK ON PLANS??? | | | 210.12 2002 NEC REQUIRES SD'S TO BE ON | | | ARC-FAULT. PLAN NOTE MENTIONS SD'S ON | | | KITCHEN/BATH LT CIRCUIT. | | | | | | NEW SHEETS TO BE INSERTED INTO SETS | | | AS REQUESTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
13:24 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-11 |
Time |
12:51 |
Sent To |
P |
|
| Notes |
| 2004-08-11 00:00:00 | ************ UNSAT ************* | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | STILL NEED TO BE ADDRESSED. | | | | | | 1)NOTE:NOTE#1 NO, PLEASE SEE TITLE BLOCK | | | HAS NOW BEEN ADDED, HOWEVER, PLEASE | | | SEE FS 471.023, IF ACTING OTHER THAN AN | | | INDIVIDUAL ENGINEER THEN YOU MUST ALSO | | | HAVE A CERT OF AUTH #. PLEASE SEE TITLE | | | BLOCK CONTAINS "CONSUKTING ENGINEERS" | | | MUST BE FOR ENGINEER ONLY. | | | | | | 2)NOTE: NOTE#2 NO, PLEASE SEE OCP FOR | | | AHU 10KW IS TILL NOT CORRECT. | | | 424.3B | | | | | | 3)NOTE: NOTE#3 PLEASE SEE THIS NOTE HAS | | | BEEN REMOVED WITH WHITE-OUT. PLANS WHICH | | | ARE SIGNED AND SEALED MAY NOT HAVE WHITE | | | -OUT CHANGES MADE. FS 471 | | | | | | 4)NOTE: NOTE#4 OK | | | | | | 5)NOTE: NOTE#5 OK, PLEASE SEE SD TO | | | BE IN THE IMMEDIATE VICINITY OUTSIDE | | | BEDROOMS. PLEASE SEE LOCATION OF SD | | | OUTSIDE DEN/GUESTBR/GUEST BR | | | | | | 6)NOTE: NOTE#6 OK FOR LOAD, HOWEVER , | | | TOTAL LOAD OF ALL HI-HATS ARE NOW BEING | | | SHOWN ON ONE 20A CIRCUIT. PLEASE SEE | | | MAX LOAD ON A 20A CIRCUIT IS 1920W'S | | | | | | 7)NOTE: NOTE#7 NO, PLEASE SEE 2' OF WALL | | | IN GUEST BR. | | | | | | 8)NOTE: NOTE#8OK | | | | | | 9)NOTE: NOTE#9 OK | | | | | | 10)NOTE: NOTE#10 OK | | | | | | 11)NOTE: NOTE#11 NO, | | | PLEASE SUBMIT AIC RATING(S) 110.9 | | | | | | 12)NOTE: PLEASE SEE RISER INDICATES A | | | 200A DISC/SERVICE AND SEC'S ARE ONLY | | | \RATED FOR 150A SERVICE. PLEASE SEE | | | 310.15B6/310.16 | | | | | | 13)NOTE: PLEASE SEE ATTACHED COPY OF | | | FS553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONAL. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO SETS FOR | | | REVIEW AND STAMPING. | | | | | | A 10% RE-SUB FEE WILL NOW BE ACCESSED | | | AND MUST BE PAID BEFORE RE-SUB. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-06 |
Time |
16:47 |
Rev Time |
0.55 |
| Received By |
dpalmer |
Date |
2004-07-22 |
Time |
10:14 |
Sent To |
M |
|
| Notes |
| 2004-07-22 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002. | | | TITLE BLOCK REQUIRED TO HAVE ALL PRINTED | | | INFORMATION AS SETFORTH PER ABOVE REF. | | | LIC #? | | | | | | 2)NOTE: PLEASE SEE 424.3B FOR OCP FOR | | | AHU HEAT. MIN 125% | | | | | | 3)NOTE: PLEASE SEE NOTE FOR SD'S TO BE | | | WIRED TO KITCH/BATH LT CIRCUITS. | | | PLEASE SEE THE FOLLOWING NOTE: 210.12 | | | | | | 4)NOTE: PLEASE SEE NOTE ON PLANS MENTION | | | 'S ALL RECEPTS TO BE AFCI. PLEASE SEE | | | WE ARE UNDER THE 2002 NEC. PLEASE SEE | | | 210.12, REQUIRED TO PROTECT ALL"OUTLETS" | | | INCL. SD'S, LTS, RECEPTS, FANS ,,,, | | | IF SD'S ARE WIRED TO KIT OR BATH CIRCUIT | | | 'S, THE AFCI PROETCTION WILL BE REQUIRED | | | FOR THOSE CIRCUITS ALSO. | | | | | | 5)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | MISSING ALL SD'S REQUIRED. | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 7)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS ON WALL SPACE. | | | | | | 8) NOTE: PLEASE SEE 210.52D FOR MISSING | | | GFI RECEPTS REQUIRED W/IN 3'OF LAV. | | | | | | 9)NOTE: PLEASE SEE SPACING ON KITCHEN | | | COUNTER RECEPTS. 210.52C1 | | | | | | 10)NOTE: PLEASE CLARIFY WHAT APPEARS TO | | | BE A RECEPT SHOWN IN THE MIDDLE OF | | | BAR SINK? GFI? 210.8 | | | | | | 11)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | PLEASE PROVIDE RM DESIGNATIONS ON PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLYINSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-24 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-24 |
Time |
18:43 |
Sent To |
P |
|
| Notes |
| 2005-05-24 00:00:00 | TO "KSTEVENS" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-05-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-20 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-20 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2005-05-20 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-11 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-11 |
Time |
14:51 |
Sent To |
G |
|
| Notes |
| 2005-05-11 00:00:00 | TO "G" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
10:55 |
Sent To |
P |
|
| Notes |
| 2004-11-12 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-25 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-25 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2004-08-25 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-06 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-06 |
Time |
16:47 |
Sent To |
E |
|
| Notes |
| 2004-08-06 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-07-21 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | TO SFD RACK/E | | 2004-07-21 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
17:08 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-08-03 |
Time |
07:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-24 |
Time |
07:43 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-24 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2004-11-24 00:00:00 | REVISION FOR S-1 SHEET |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-11 |
Time |
12:51 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-08-14 |
Time |
15:23 |
Sent To |
B |
|
| Notes |
| 2004-08-14 00:00:00 | UNABLE TO PASS PLUMBING PLANS WITHOUT | | | A SANITARY RISER DIAGRAM TO SEE IS THE | | | PLUMBING IS VENTED PROPERLY - ONLY FLAT | | | PLUMBING LAYOUT IS SHOWN ON SHEET S-1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-27 |
Time |
17:08 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-07-27 |
Time |
17:08 |
Sent To |
M |
|
| Notes |
| 2004-07-27 00:00:00 | NO RISER DIAGRAM. NOT ENOUGH INFORMATION | | | TO DO PLAN REVIEW FOR PLUMBING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-21 |
Time |
12:26 |
Sent To |
I |
|
| Notes |
|
|