| Plan Review Stops For Permit 04070846 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-09 |
Time |
09:37 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2005-02-08 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-20 |
Time |
17:41 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-08-04 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2005-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-22 |
Time |
15:29 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-22 |
Time |
15:29 |
Sent To |
Z |
|
| Notes |
| 2005-06-22 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. PLEASE SEE ONLY | | | ONE COPY OF LOAD CALCS AND SPECS FOR | | | HEAT PUMP WERE SUBMITTED. | | | | | | 2)NOTE: PLEASE SEE ALL CONTINUOUS LOADS | | | ARE TO BE SHOWN AT 125%. | | | 215.3,230.42,680.9 | | | | | | 3)NOTE: PLEASE CORRELATE ELECTRICAL POOL | | | WIRING DIAGRMA WITH POOL EQUIPMENT SHOWN | | | ON PLANS. POOL EQUIP SHOWS 3-PUMPS, 1- | | | BLOWER ETC AND WIRING DIAGRAM SHOWS | | | 2-PUMPS AND NO BLOWER. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | PLANS ROUTED TO ZONING AS NEW SITE | | | PLAN/SURVEY WAS SUBMITTED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-01-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-26 |
Time |
16:05 |
Rev Time |
0.30 |
| Received By |
dpalmer |
Date |
2005-01-26 |
Time |
16:05 |
Sent To |
P |
|
| Notes |
| 2005-01-26 00:00:00 | NEW PLANS SUBMITTED, SENT TOPLUMB FOR | | | REVIEW AND STAMPING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-11-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-17 |
Time |
07:44 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-17 |
Time |
07:44 |
Sent To |
P |
|
| Notes |
| 2004-11-17 00:00:00 | ******** UNSAT 3RD REVIEW ******** | | | | | | 1)NOTE: PLEASE SEE SAME NOTES FROM TWO | | | PREVIOUS REVIEWS. | | | LOAD CALCAULTIONS ETC HAVE STILL NOT | | | BEEN SUBMITTED.?? 215.5 | | | SUBMIT SPECS FOR HEAT PUMP SHOWING A | | | LISTING FROM A NRTL. | | | | | | 2)NOTE: PLEASE SEE RISER NOW SHOWS A NEW | | | FEED FROM EXSITNG PANEL. PLEASE SEE | | | MISSING EQUIPMENT GROUNDING CONDUCTOR. | | | 250.24,250.122 | | | | | | 3)NOTE: ENGINEER MUST ALSO DATE PLANS | | | WHEN SIGNING. MAY NOT BE A | | | PRINTED/STAMPED. FS 471.025 | | | | | | | | | 4)NOTE: PLEASE SEE ATTACHED COPY OF FS | | | 553.80(2)(B) WHICH IS ATTACHED WITH | | | RESPECT TO DESIGN PROFESSIONAL. | | | THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | | | | PLEASE SEE FIVE SETS OF PLANS ARE BEING | | | SUBMITTED. ONLY TWO IS NEEDED AND THREE | | | MAY BE SUBMITTED. ONLY THREE WILL BE | | | STAMPED UPON COMPLETETION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-14 |
Time |
14:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-09-14 |
Time |
14:59 |
Sent To |
P |
|
| Notes |
| 2004-09-14 00:00:00 | *********** UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW. | | | PLEASE SUBMIT LOAD CALCUALTIONS FOR | | | SERVICE/PANELS. PLEASE INCLUDE ALL NEW | | | LOADS ALONG WITH EXSITING LOADS. | | | PLEASE ALSO INCLUDE SIZE OF EXISTING | | | SERVICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
16:11 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2004-07-22 |
Time |
14:37 |
Sent To |
P |
|
| Notes |
| 2004-07-22 00:00:00 | | | | PLEASE PROVIDE A CALCULATION | | | INCLUDING ALL ADDED LOADS IMPOSED,ALL | | | EXISTING LOADS AND THE EXISTING OR | | | PROPOSED SERVICE SPECIFICATIONS PER | | | 215.15. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
16:26 |
Sent To |
P |
|
| Notes |
| 2005-07-01 00:00:00 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-06-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-06-16 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2005-06-16 |
Time |
13:41 |
Sent To |
E |
|
| Notes |
| 2005-06-16 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-20 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-20 |
Time |
15:27 |
Sent To |
E |
|
| Notes |
| 2005-01-20 00:00:00 | TO "DP" DESK./RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
11:07 |
Sent To |
E |
|
| Notes |
| 2004-11-12 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-26 |
Time |
16:11 |
Sent To |
E |
|
| Notes |
| 2004-08-26 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
09:41 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-21 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-21 |
Time |
09:07 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-07-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-07-09 |
Time |
09:37 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-07-09 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-02-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-02-05 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-02-05 |
Time |
11:45 |
Sent To |
B |
|
| Notes |
| 2005-02-05 00:00:00 | BACK FLOW PREVENTER INSTALLED PRIOR | | | STARTING WORK. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-24 |
Time |
13:51 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-11-24 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-09-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-20 |
Time |
17:41 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-09-20 |
Time |
17:41 |
Sent To |
B |
|
| Notes |
| 2004-09-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | 1) COMMENTS FROM FIRST REVIEW HAVE NOT | | | BEEN ADDRESSED. PLEASE SEE COMMENTS THAT | | | ARE ATTACHED TO THE PERMIT APPLICATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-09-14 |
Time |
14:59 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-08-02 |
Time |
18:33 |
Sent To |
B |
|
| Notes |
| 2004-08-02 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | FBC-2001 CHAPTER 1 | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | 3) NO VACUUM LINE SHOWN ON THE POOL LAY- | | | OUT. THIS IS CALLED OUT ON POOL SPECIFI- | | | CATIONS. PLEASE CORRELATE LAYOUT & SPECS | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2005-06-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-06-30 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-06-30 |
Time |
11:52 |
Sent To |
I |
|
| Notes |
| 2005-06-30 00:00:00 | REVISION - POOL EQUIP. ONLY. | | | **POOL EQUIP. CAN ONLY ENROACH 4FT INTO | | | SETBACK** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-02-08 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-02-08 |
Time |
12:39 |
Sent To |
B |
|
| Notes |
| 2005-02-08 00:00:00 | RESTAMP SURVEY. RETURNED PLANS TO LEA | | | SMITH TO ISSUE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-21 |
Time |
15:53 |
Sent To |
I |
|
| Notes |
|
|