| Plan Review Stops For Permit 04070798 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-15 |
Time |
13:54 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-11-15 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | FRAMING REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-08-02 |
Time |
11:17 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2005-08-02 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | REVISION FOR DOORS AND WINDOWS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-12-10 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-12-10 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-11-16 |
Time |
09:42 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-11-16 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2004-11-16 00:00:00 | DENIED | | | COMMENT FROM LAST REVIEW. | | | | | | ALL PRODUCT APPROVALS REQUIRE THE | | | FOLLOWING TO BE ATTACHED TO QUALITY | | | ASSURANCE TEST (MIAMI-DADE) FOR | | | EXAMPLE. | | | | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | | | | CHECK NOTES FROM OTHER REVIEWERS THAT | | | MIGHT EFFECT THE ISSUING OF A PERMIT. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-03 |
Time |
14:06 |
Rev Time |
3.75 |
| Received By |
alange |
Date |
2004-08-04 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2004-08-04 00:00:00 | DENIED | | | | | | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY | | | COURTHOUSEAND A COPY SUBMITTED TO THIS | | | OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.PRODUCT APPROVALS MISSING FOR | | | MASONITE STEEL EDGE WOOD DOORS, SUBMIT | | | 2 COPIES. | | | | | | 4.PRODUCT APPROVALS MISSING FOR ALL | | | ARCHED WINDOWS. SUBMIT 2 COPIES. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5.SEPERATE POOL PERMIT REQUIRED | | | | | | 6.SUBMIT PRODUCT APPROVALS FOR | | | ALL STRAPS AND TIEDOWNS. | | | | | | 7. BUILDING VALUATION HAS BEEN REVISED | | | TO $259,947 BASED ON SBCCI BUILDING | | | VALUATION DATA. | | | A/C 2995 SQ. FT. X $76.96 = $230,495 | | | OTHER 708 SQ.FT. X $41.60 = $29,452 | | | | | | 8.FBC 2309.6SHOW LOCATION AND SIZE | | | OF ATTIC ACCESS. | | | | | | 9. FIREPLACE DETAILS NOT READABLE, | | | PLEASE SUBMIT NEW DETAILS. | | | | | | 10.DOOR #13 NOT SHOWN ON NORTH | | | ELEVATION, | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | ART LANGE | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6672 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-17 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-17 |
Time |
18:53 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-20 |
Time |
15:30 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-10-20 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | ********** PROVISO/REVISION *********** | | | | | | 1)NOTE: PLEASE CORRELATERISER DIAGRAM | | | ALONG WITH PANEL SCHEDULES FOR GARAGE | | | PANEL. | | | PER OWNER, #1 AWG IS INSTALLED. | | | PLEASE SEE OCP IN MM AND RISER TO MATCH, | | | SHOWS 70A AND 60A. | | | PLEASE SEE RISER INDICATES SUB PANEL ON | | | 2ND FLR, HOWEVER PANEL IS LOCATED ON | | | FIRST FLR RM. | | | PLEASE INDICATE UTILITY RM UNDER STAIRS | | | AS ELECTRICAL ROOM/ NO STORAGE. | | | 240.24D,408.7, 215.5, 240.4,310.16 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 | | | | | | 3)NOTE: PLEASE SEE MISSING SD LOCATED | | | OUTSIDE MASTER BEDRM AT TOP OF STAIRS. | | | THIS WAS REDLINED ON PREVIOUS PLANS. | | | NFPA-72 8-1.4.1.6.2 | | | | | | 4)NOTE:PLEASE SEE MISSING GFI AT | | | PENINSULAR. PER OWNER, THIS WILL BE IN | | | CABINETS AND ONLY TO STUB OUT AT THIS | | | TIME. | | | 210.52C3 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW AND STAMPING BEFORE FINAL | | | ELECTRICAL INSPECTION IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-23 |
Time |
07:08 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-11-23 |
Time |
07:08 |
Sent To |
M |
|
| Notes |
| 2004-11-23 00:00:00 | REDLINED SD LOCATION ON SECOND FLR, MAY | | | BE ONE IN CENTRAL AREA OUTSIDE BEDRMS. | | | REDLINED MISSING RECPT FOR 2' OF WALL | | | SECOND FLR BEDRM.210.52 | | | BATH GFI IN GARAGE REDLINED ON ONE SET. | | | | | | HAND DRAWN CHANGE FOR 70A SUB-PANEL FEED | | | OK. | | | | | | THESE ITEMS ARE REDLINED ON PLANS AND DO | | | NOT NEED TO BE SUBMITTED FOR A | | | REVISION. | | | | | | IF THERE ARE ANY OTHER REV'S AS THE | | | PROJECT IS FURTHER ALONG, PLEASE MAKE | | | THESE HARD CHANGES AT THAT TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-23 |
Time |
06:30 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-10-23 |
Time |
06:07 |
Sent To |
P |
|
| Notes |
| 2004-10-23 00:00:00 | IN ELEC FOR REVIEW. | | | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FBC 104.2.1, PLANS | | | ARE ALSO REQUIRED TO BE SIGNED BY THE | | | PERSON RESPONSIBLE FOR PLANS. | | | | | | 2)NOTE: PLEASE SEE MECHANICAL PLANS ARE | | | DRAWN OVER ELECTRICAL PLANS. THESE | | | CONTAIN AN ARCH'S TITLE BLOCK. | | | IF TITLE BLOCK IS PRESENT, THEN PLANS | | | ARE REQUIRED TO BE SIGNED DATED AND | | | SEALED BY THE ARCH. FS481.221 | | | PLEASE ALSO EITHER REMOVE ELECTRICAL | | | FROM PLANS. | | | | | | 3)NOTE: PLEASE SEE ELECTRICAL RISER SHOW | | | 'S A PANEL FOR SEOND FLR AND SHOWS A | | | 70A DISC, YET THERE IS NO INDICATION | | | WHERE THIS PANEL IS FED FROM? | | | PLEASE SEE 200A PANEL DOES NOT INDICATE | | | THIS BEING FED. | | | | | | 4)NOTE: PLEASE VERIFY WATER HEATER SIZE, | | | SEEMS TO BE TOO SMALL FOR A HOUSE THIS | | | SIZE. PLEASE SEE PLUMB CODE FOR MIN | | | SIZE REQUIRED. | | | | | | 5)NOTE: PLEASE SEE MISSING GFI IN BATH | | | RM AT GARAGE. 210.52D, 210.11C3 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO TWO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-08-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-15 |
Time |
09:50 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-02 |
Time |
13:39 |
Sent To |
M |
|
| Notes |
| 2004-08-02 00:00:00 | *********** UNSAT ************ | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAMS. | | | TWO SUBMITTED?? | | | PLEASE ALSO CORRELATE WITH PANEL SCHED- | | | -ULES. | | | | | | 2)NOTE: PLEASE SEE 310.16 FOR SIZING | | | OF FEEDERS AND SEC'S. SHOWS 1/0'S FOR | | | 200A SERVICE? ETC. | | | | | | 3)NOTE: PLEASE SEE 30A OCP FOR WASHER? | | | | | | 4)NOTE: PLEASE SHOW LOCATION OF PANELS / | | | SERVICE EQUIPMET ON PLANS. | | | | | | 5)NOTE: PLEASE SEE 250.50 FOR REQUIRED | | | CWP FOR GROUNDING ELECTRODE. | | | | | | 6)NOTE: PLEASE SEE "NOTE" MENTIONS SD'S | | | ATTACHED TO KITCHEN LT CIRCUIT. | | | PLEASE SEE 210.12 2002 NEC SD'S ARE | | | REQUIRED TO HAVE ARC FAULT PROTECTION. | | | | | | 7)NOTE: PLEASE SEE FBC 104.2.1, PLANS | | | ARE REQUIRED TO HAVE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | PLANS. | | | THIS IS REQUIRED ON ALL SHEETS,WHEATHER | | | OR NOT COMMENT IS MADE BY OTHER REVIEW- | | | -ERS. | | | | | | 8)NOTE: PLEASE ALSO SEE PLANS MENTIONS | | | BEDRM RECEPTS TO BE ARC FAULT PROT. | | | PLEASE SEE 2002 NEC 210.12. | | | LTS/FANS/RECEPT, SD. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
10:27 |
Sent To |
E |
|
| Notes |
| 2006-03-16 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
09:35 |
Sent To |
M |
|
| Notes |
| 2005-10-22 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-20 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-20 |
Time |
10:03 |
Sent To |
E |
|
| Notes |
| 2005-10-20 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-29 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-29 |
Time |
14:55 |
Sent To |
B |
|
| Notes |
| 2005-07-29 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-07-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-07-26 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2005-07-26 00:00:00 | GAVE TO ART |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-19 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-19 |
Time |
14:30 |
Sent To |
E |
|
| Notes |
| 2004-11-19 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-15 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-15 |
Time |
09:49 |
Sent To |
E |
|
| Notes |
| 2004-10-15 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2004-07-29 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-07-21 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | TO SFD RACK/E | | 2004-07-21 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-09 |
Time |
12:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-11-09 |
Time |
12:40 |
Sent To |
B |
|
| Notes |
| 2005-11-09 00:00:00 | 11-9-05 MECH. REV. TO PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-12-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-09 |
Time |
06:45 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-12-09 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2004-12-09 00:00:00 | PROVISO ON PLAN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-11-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-16 |
Time |
06:31 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-11-15 |
Time |
17:45 |
Sent To |
B |
|
| Notes |
| 2004-11-16 00:00:00 | DENIED: | | | MECHANICAL PLANS SUBMITTED HAVE A TITLE | | | BLOCK INDICATED ON THE PLAN.WHEN THE | | | TITLE BLOCK IS PRESENT, PLANS ARE | | | REQUIRED TO BE SIGNED, SEALED AND DATED | | | BY THE ARCHITECT IN ACCORDANCE WITH FS | | | 481.221.PLEASE HAVE ARCHITECTECT | | | COMPLY OR REMOVE THE TITLE BLOCK. | | | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS @ (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-28 |
Time |
18:36 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-08-03 |
Time |
14:04 |
Sent To |
B |
|
| Notes |
| 2004-08-03 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.ENERGY AND MANUAL J CALCS | | | SUBMITTED WITH BUILDING PERMIT | | | APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-28 |
Time |
18:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-28 |
Time |
18:36 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-23 |
Time |
06:30 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-07-31 |
Time |
08:30 |
Sent To |
E |
|
| Notes |
| 2004-07-31 00:00:00 | RISER DIAGRAM NOT TO CODE AND FIXTURES | | | ARE MISSING. | | | 1/2 BATH MISSING FROM RISER DIAGRAM. | | | BATHROOM ON FIRST FLOOR IS NOT VENTED | | | RISER FOR SECOND FLOOR PLUMBING MUST | | | DISCHARGE DOWN STREAM OF BATHROOM GROUP. | | | W/M NOT VENTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2004-10-18 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2004-10-18 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2004-10-18 00:00:00 | 10/18/04 ***PASSED*** | | | | | | THE WING WALL ON THE SE CORNER OF THE | | | BUILDING SHALL NOT EXCEED 6' IN HEIGHT. | | | | | | REFER TO ENCLOSED SURVEY FOR APPROVED | | | SITE PLAN.SITE PLAN WITH THE PLANS | | | DOES NOT HAVE A SCALE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2004-07-29 |
Time |
13:19 |
Sent To |
I |
|
| Notes |
| 2004-07-29 00:00:00 | 7/29/04 - FAILED. | | | | | | 1) PLEASE PROVIDE A SCALED DRAWING OF | | | THE SITE PLAN. | | | | | | 2) THE POOL WILL NEED TO BE 10' FROM THE | | | PROPOSED PROPERTY LINE...UNTIL TEXT | | | CHANGE HAS BEEN APPROVED (DATE UNKNOWN). | | | | | | 3) THE TOWER ON THE GARAGE MAY NOT | | | EXCEED 30' IN HEIGHT.HEIGHT IS | | | MEASURED FROM GRADE, NOT FINISHED FLOOR | | | ELEVATION. | | | | | | 4) THE WING WALL ON THE SOUTHEAST CORNER | | | OF THE HOUSE MUST BE SHOWN ON THE SITE | | | PLAN.MAXIMUM HEIGHT MAY NOT EXCEED 6' | | | IN HEIGHT. | | | | | | 5) THE EXTERIOR DOOR TO THE GARAGE | | | BATHROOM IS NOT SHOWN ON THE NORTH | | | ELEVATION. | | | | | | PLEASE CONTACT JOHN ROACH, PLANNER FOR | | | ANY QUESTIONS.(561) 822.1435 |
|
|