| Plan Review Stops For Permit 04070719 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-07-27 |
Time |
13:00 |
Rev Time |
0.66 |
| Received By |
btrobaug |
Date |
2004-07-27 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2004-07-28 00:00:00 | BUIDING REVIEW OK. | | | SEE ZONING COMMENTS. | | | ART LANGE | | | BUILDING PLAN REVIEW | | | TEL: (561)805-6672 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2005-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-01-31 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-01-31 00:00:00 | SEE REVIEW UNDER # 04090570 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-27 |
Time |
16:12 |
Rev Time |
0.75 |
| Received By |
nleiva |
Date |
2004-07-27 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2004-07-30 00:00:00 | ELECRTICAL PERMIT WILL BE APPLIED FOR | | | SEPERATELY OK PR L MARTINEZ/DRUNNELS NFL | | 2004-07-27 00:00:00 | *********** UNSAT ****************** | | | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | | REQUIRED ON AND FOR TITLE BLOCK. | | | FAC 61G15-23.002 | | | THIS IS REQUIRED ON ALL SHEETS WHEATHER | | | OR NOT COMMENT IS MADE BY OTHER REVIEW- | | | -ERS. | | | | | | 2)NOTE: PLEASE CLARIFY SERVICE? | | | SEEMS TO SHOW AND EXSITING SERVICE | | | GOING TO "TELCO" PANEL AND NEW SERVICE | | | FOR NEW EQUIPMENT? | | | THESE BOTH SEEM TO CROSS OVER FROM EACH | | | SERVICE ON RISER DIAGRAM?? | | | | | | 3)NOTE: PLEASE SEE 250.24,250.6, AN | | | EQUIPMENT GROUNDING CONDUCTOR MAY NOT | | | BE INSTALLED UNTIL AFTER THE FIRST MEANS | | | OF DISC. | | | | | | 4)NOTE: PLEASE SEE FBC 104.6.5, VALUE | | | ON APPLICATION IS TO INCLUDE ALL LABOR | | | AND MATERIALS, EVEN IF ANY OR ALL IS | | | OWNER SUPPLIED. | | | ALL EQUIPMENT ETC IS TO BE INCLUDED. | | | | | | 5)NOTE: PLEASE SEE PLANS ARE ONLY IN FOR | | | PLAN REVIEW AND NOT FOR PERMIT. | | | | | | 6)NOTE: PLEASE SEE ZONING NOTES. | | | PLANS ARE TO PLACED ON HOLD. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2004-07-19 |
Time |
16:25 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2004-07-19 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | PASSED WITH PROVISOS: | | | 1. IF GARBAGE IS TO BE PICKED UP BY THE | | | CITY THEN THE ENCLOSURE MUST BE SIZED | | | PER CITY' REQUIREMENTS, 12'-6" OPENING | | | BETWEEN THE GATE POSTS, AND 12'-6" WIDE | | | 12'-0" DEEP,AND A 10'-0" LONG CONCRETE | | | PARKING STOP. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-01-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-01-28 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-01-28 |
Time |
07:57 |
Sent To |
E |
|
| Notes |
| 2005-01-28 00:00:00 | TO "DP" DESK/RESUB. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-12-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-07 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-07 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2004-12-07 00:00:00 | SENT TO COMM BD#61 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-30 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
nleiva |
Date |
2004-07-19 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | TO COMM BD#15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2005-01-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-01-27 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-01-27 |
Time |
15:44 |
Sent To |
I |
|
| Notes |
| 2005-01-27 00:00:00 | PROVISO: MUST PROVIDE COPY OF COVER PAGE | | | T1 AND SHEET #C2, BEFORE C.O. IS | | | ISSUED. | | | ANY QUESTIONS, PLEASE CALL DAVID KANNING | | | AT 822-1435, PLANNING DEPT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2004-12-15 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
dkanning |
Date |
2004-12-14 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2004-12-21 00:00:00 | THE RELOCATION OR REMOVAL OF ANY TREE | | | REQUIRES A TREE REMOVAL PERMIT.CALL | | | ALAN BARATTA FOR MORE INFORMATION: | | | 822-1462 | | 2004-12-16 00:00:00 | THE 1" = 5'-0" SCALE IS INCORRECT. | | 2004-12-15 00:00:00 | THE COCOPLUMS SHALL NOT BE PLANTED OVER | | | THE CONCRETE FOUNDATION ON THE | | | DUMPSTER'S SOUTH SIDE. | | | | | | THE COCOPLUMS SHALL BE PLANTED SO THAT | | | THE MECHANICAL EQUIPMENT DOOR DOES NOT | | | OPEN INTO THE COCOPLUM ON THE SOUTH SIDE | | | OF THE DUMPSTER. | | | | | | THE COCOPLUMS SHALL BE PLANTED ACCORDING | | | TO SECTION 94-446 OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS.SEE | | | WWW.MUNICODE.COM | | | | | | THE LANDSCAPE NOTES SHALL BE AMENDED TO | | | STATE THE FOLLOWING UNDER "B. QUALITY | | | ASSURANCE" | | | | | | B. QUALITY ASSURANCE: | | | 1.PLANTS AND TREES: BALLED AND | | | BURLAPPED PLANTS AND TREES SHALL BE | | | GRADED TO AMERICAN STANDARD FOR NURSURY | | | STOCK, ANSI Z60.1 AND SHALL BE FLORIDA | | | GRADE #1 IN ACCORDANCE WITH FLORIDA | | | DEPARTMENT OF AGRICULTURE GRADES AND | | | STANDARDS. | | | | | | 5. CONTRACTOR SHALL WATER SEEDED AREAS | | | AS OFTEN AS REQUIRED TO OBTAIN | | | GERMINATION AND TO OBTAIN AND MAINTAIN | | | SATISFACTORY GROWTH UNTIL ESTABLISHED. | | | | | | 9. TREES AND SHRUBS MUST BE MAINTAINED | | | AND SURVIVE FOR A MINIMUM OF 1 YEAR OR | | | UNTIL ESTABLISHED. | | | | | | THE LANDSCAPE MATERIALS (SECTION 5) | | | SHALL NOT INCLUDE ANY TYPE OF GRAVEL | | | MATERIAL.THE REFERENCE TO THE GRAVEL | | | SHALL BE STRICKEN. | | | | | | | | | | | | | | | | | | THE DUMPSTER WALLS SHALL NOT ENCROACH | | | INTO THE 24 FOOT WIDE DRIVE AISLE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2004-07-30 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-30 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2004-07-30 00:00:00 | APPROVED WITH PROVISO: IF GARBAGE IS TO | | | BE PICKED UP BY THE CITY, THE ENCLOSURE | | | MUST BE SIZE PER CITY'S CODES AS PER | | | SECTION : 94-444/FIQURE: XIV-3 | | | PLANS REVIEWED BY DAVID KANNING, PLANNER | | | 822-1443, NEED UTILITY EASEMENT | | | APPROVAL MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-22 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-22 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | DENIED, DUMPSTER DOES NOT MEET CODE & | | | MUST PROVIDE UNITY OF TITLE.PER DAVID | | | KANNING, PLANNER 659-8031 MM |
|
|