Plan Review Details - Permit 04070534
Plan Review Stops For Permit 04070534
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-08-11 Cont ID  
Sent By lsmith Date 2004-08-11 Time 13:40 Rev Time 0.50
Received By lsmith Date 2004-08-11 Time 13:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-27 Cont ID  
Sent By dpalmer Date 2004-08-11 Time 10:55 Rev Time 0.50
Received By lsmith Date 2004-07-27 Time 08:55 Sent To  
Notes
2004-07-27 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. SUBMIT METHOD OF COMPLIANCE WITH POOL
 SAFETY ACT. (BABY BARRIER, ALARMS, ETC.)
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-11 Cont ID  
Sent By dpalmer Date 2004-08-11 Time 10:55 Rev Time 0.25
Received By dpalmer Date 2004-08-11 Time 10:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-07-19 Cont ID  
Sent By kstevens Date 2004-08-10 Time 17:24 Rev Time 0.33
Received By dpalmer Date 2004-07-19 Time 13:18 Sent To P
Notes
2004-07-19 00:00:00*************** UNSAT **************
  
 1)NOTE: PLEASE CORRELATE PERMIT APPLI-
 -CATION AND PLANS. APPL MENTIONS NEW
 GAS HEATER YET RISER SHOWS ELEC HEAT
 PUMP. ? IF NEW HEAT PUMP, THEN SUBMIT
 LOAD CALCS AND SHOW WIRE SIZES ETC.
  
 2)NOTE: RISER SHOWS A NEW PANEL, PLEASE
 INCLUDE FEEDER OCP , AWG AND CONDUIT
 SIZE.
  
 3)NOTE: PLEASE CORRELATE ELECTRICAL
 RISER WITH ALL EQUIPMENT SHOWN ON PIPING
 DIAGRAM.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-30 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:27 Rev Time 0.00
Received By csiegber Date 2004-07-30 Time 16:27 Sent To P
Notes
2004-07-30 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-07-19 Cont ID  
Sent By csiegber Date 2004-07-19 Time 12:46 Rev Time 0.00
Received By csiegber Date 2004-07-19 Time 12:46 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-13 Cont ID  
Sent By mmclean Date 2004-07-19 Time 10:06 Rev Time 0.00
Received By mjacobs Date 2004-07-13 Time 16:19 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-08-10 Cont ID  
Sent By kstevens Date 2004-08-10 Time 17:24 Rev Time 0.50
Received By kstevens Date 2004-08-10 Time 17:23 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-27 Cont ID  
Sent By csiegber Date 2004-07-30 Time 16:27 Rev Time 0.60
Received By kstevens Date 2004-07-27 Time 07:51 Sent To B
Notes
2004-07-27 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) PIPING SCHEMATIC DOES NOT REFLECT THE
 POOL LAYOUT. SCHEMATIC SHOWS A TWO PUMP
 SYSTEM WITH AUX. POOL JETS. NOT SHOWN ON
 THE POOL LAYOUT OR SHOWN ON THE POOL
 DATA & EQUIPMENT SCHEDULE. PLEASE CORRE-
 LATE SCHEMATIC WITH POOL LAYOUT/EQUIP.
 SCHEDULE. SECTION 104.2.1
 3) GENERAL NOTES: TESTS, INDICATES AIR
 TEST, THIS IS NOT APPROVED. PLEASE DELE-
 TE FROM NOTES. SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-19 Cont ID  
Sent By mjacobs Date 2004-07-13 Time 16:20 Rev Time 0.00
Received By mmclean Date 2004-07-19 Time 10:06 Sent To I
Notes
***NONE***