| Plan Review Stops For Permit 04070519 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-10-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-10-29 |
Time |
14:35 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2004-10-29 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-26 |
Time |
12:24 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-08-26 |
Time |
12:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-10 |
Time |
08:28 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-08-10 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2004-08-10 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. SEE NOTE 1 ON FIRST REVIEW: NEED | | | FLORIDA PRODUCT APPROVALS FOR | | | STOREFRONT& DOORS.IF NOT AVAILABLE | | | A "LOCAL PRODUCT APPLICATION MUST BE | | | SUBMITTED. SEE FORM ATTACHED. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-16 |
Time |
10:02 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-07-16 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. SUBMIT FLORIDA STATE & DADE COUNTY OR | | | SBCCI PRODUCT APPROVALS FOR STOREFRONT | | | ASSEMBLY. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-13 |
Time |
08:10 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-12-13 |
Time |
07:52 |
Sent To |
P |
|
| Notes |
| 2004-12-13 00:00:00 | OWES REV FEE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-11-01 |
Time |
15:10 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-11-01 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2004-11-01 00:00:00 | ********* UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE NOTES/PROVISO GIVEN | | | ON PREVIOUS REVIEW. | | | THESE CHANGES ARE REQUIRED TO BE MADE AT | | | THIS TIME. | | | | | | 2)NOTE: PLEASE ALSO SEE THAT ELECTRICLA | | | PLANS HAVE COME IN FOR A REVISION, YET | | | THERE DOES NOT SEEM TO BE ANY ELECTRICAL | | | CHANGES MADE??? | | | PLEASE IDENTIFY ALL REV'S W/ | | | CLOUDS/TRIANGLES AND NOTE IN TITLE | | | BLOCK. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-24 |
Time |
15:59 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-24 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2004-08-24 00:00:00 | *** PROVISO/ REVISION ****** | | | | | | 1)NOTE: | | | PLEASE SEE CONDUIT FOR TYPICAL UNITS | | | AS 1 1/2" MUST BE SIZED PER NEC TABLES. | | | IF PVC THIS CONDUIT IS TOO SMALL. | | | | | | 2)NOTE: | | | PLEASE ALSO SEE PREVIOUS NOTES FOR | | | A MIN OF ONE LT FIXTURE REQUIRED FOR | | | LS 101 5-8. PLANS STILL SHOW J-BOX AND | | | NO LT FIXTURE. | | | | | | PLANS ARE TO BE REVISED AND SUBMITTED | | | FOR REVIEW BEFORE ROUGH ELECTRICAL | | | INSPECTION IS CALLED. IN. | | | | | | IF THERE ARE NAY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-19 |
Time |
15:09 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-19 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE CORRELATE CIRCUIT #'S | | | AHOWN ON PLANS WITH PANEL SCHEDULE. | | | PLEASE SEE 700.12E. EM LT SHOWN ON | | | SHOW WINDOW CIRCUITS. | | | PLEASE SHOW A MIN OF ONE COMPLETE TYP | | | UNIT. | | | | | | 2)NOTE: PLEASE SEE FEEDERS TO 150A | | | PANELS. THESE DO NOT SHOW A NEUTRAL? | | | PLEASE ALSO CHECK CONDUIT TYOE AND SIZE. | | | | | | 3)NOTE: PLEASE SEE 210.62 FOR REQ'D | | | SHOW WINDOW RECEPTS. PANEL SCHEDULE | | | INDICATES CIRCUITS BUT PLAN DOES NOT | | | SHOW RECEPTS?? | | | | | | 4)NOTE: PLEASE SEE LS 101 5-8 WHICH | | | REQUIRES A MIN EGRESS LIGHTING IN BLDG. | | | PLANS SHOW OUTLETS AS BEING J-BOX ONLY | | | AND NO FIXTURE INDICATED. A MIN OF ONE | | | LT SHALL BE REQUIRED. | | | | | | 5 )NOTE: PLEASE SHOW LOAD CALCULATIONS, | | | PLEASE SHOW PER | | | 220.3,220.10,220.11,220.13 ETC. | | | PLEASE ALSO SHOW ALL CONTINOUS LOADS | | | AT 125% PER 215.3,230.42 | | | TYP NOTE" | | | | | | PLEASE VERIFY NOTE IN THE MIDDLE OF PLAN | | | -S CALL FOR EXISTING ELEC TO REMAIN UON? | | | PLEASE CLARIFY, PLANS ARE SHOWING ALL | | | AS NEW AT THIS TIME?? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | WATER/ ETC. SIZE ALL PER 250.66 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-30 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-30 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-12-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-06 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-06 |
Time |
16:56 |
Sent To |
E |
|
| Notes |
| 2004-12-06 00:00:00 | SENT TO "DP" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-11-24 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-11-24 |
Time |
13:08 |
Sent To |
M |
|
| Notes |
| 2004-11-24 00:00:00 | SENT TO "M/AC" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-29 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-25 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2004-10-29 00:00:00 | TO COMM BD#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-05 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2004-08-05 00:00:00 | TO COMM BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-07-13 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-07-13 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2004-07-13 00:00:00 | SENT TO "COMM" BOARD #64 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-12-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-12-08 |
Time |
12:35 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-12-08 |
Time |
12:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-11-02 |
Time |
14:00 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-11-02 |
Time |
14:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
07:56 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-08-26 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-21 |
Time |
13:23 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-21 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | DENIED: | | | PLANS DO NOT INDICATE WHAT THE OUTSIDE | | | AIR CALCULATION WILL BE.NOTE #16 ON | | | PLAN SHEET 2 OF 2 INDICATES O.A. WILL BE | | | IN COMPLIANCE WITH ASHRAE 62-1989.THE | | | MECHANICAL PLANS BY "KEEP IT COOL" DO | | | NOT INDICATE WHAT THE O.A. WILL BE. | | | PLEASE CLARIFY. | | | | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-19 |
Time |
14:49 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-11-19 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2004-11-19 00:00:00 | NO PLUMBING REVISION NOTED. PLEASE CLOUD | | | ALL CHANGES AND INDICATE CHANGE WITH A | | | REVISION NUMBER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-23 |
Time |
18:09 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-08-23 |
Time |
18:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-29 |
Time |
17:46 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-29 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | DENIED | | | REFRERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT 1 DRINKING FOUNTAINS ARE REQUIRED | | | FOR EACH SPACE. TABLE 403.1 - ALSO SEE | | | SECTION 410.1. | | | 2) SHT 2 WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AS SHOWN. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-11 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|