| Plan Review Stops For Permit 04070421 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-09-14 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2005-09-14 00:00:00 | PLANS WERE SENT TO MR.ROBERT BROWN | | | OFFICE FOR SITE SPECIFIC APPROVAL. MJ |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-09-09 |
Time |
12:51 |
Rev Time |
1.50 |
| Received By |
mjacobs |
Date |
2005-09-09 |
Time |
10:39 |
Sent To |
PC |
|
| Notes |
| 2005-09-09 00:00:00 | 1)THE APPLICATION FOR SITE SPECIFIC IS | | | NOT COMPLETE. THE ARCHITECT OF RECORD OR | | | FRANK L. BENNARDO,P.E SHALL COMPLETE | | | ITEM SEVEN (7) OF THE PRODUCT APPROVAL | | | FORM OR WRITE A SIGNED/SEALED LETTER | | | CONFIRMING RESPONSIBILITY AS THE "THIRD | | | PARTY QUALITY ASSURANCE ENTITY". | | | | | | BUILDING PLAN REVIEW | | | MYRON JACOBS | | | TEL: (561)805-6726 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-29 |
Time |
08:03 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-07-29 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2004-07-29 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. SEE ELECTRICAL NOTES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-28 |
Time |
19:13 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2004-07-20 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. THE PLANS MUST BE TAKEN TO PBC AND | | | IMPACT FEES PAID.THE PLANS WILL BE | | | STAMPED & A RECEIPT ISSUED FOR THE | | | IMPACT FEES. THIS MUST BE COMPLETED | | | BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK OF THE | | | COURT'S OFFICE & A COPY OF THE RECORDED | | | NOC SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | 3. PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. GO TO | | | WWW.FLORIDABUILDING.ORG ON THE WEBB FOR | | | MORE INFORMATION. | | | THE FOLLOWING PRODUCT APPROVALS WILL BE | | | REQUIRED BEFORE PERMITTING: | | | A. WINDOWS (IMPACT) PER PLANS | | | B. EXTERIOR DOORS (IMPACT) PER PLANS | | | C. GARAGE DOORS | | | D. ROOFING MATERIALS | | | E. STRUCTURAL COMPONENTS (HURRICANE | | | STRAPS, ETC. USP & SIMPSON). | | | | | | 4. A SURVEY SHOWING THE PROPOSED | | | RESIDENCE IS REQUIRED. | | | | | | NOTE: SUBMIT 2 COPIES OF ALL SUBMITTALS. | | | NOTE: THE PLANS SHOW PAVERS & A POOL. | | | THESE WILL REQUIRE SEPARATE PERMITS. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-08-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-08-12 |
Time |
13:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-08-12 |
Time |
12:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-22 |
Time |
13:19 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-07-22 |
Time |
13:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-07-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-07-30 |
Time |
12:35 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-07-30 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-28 |
Time |
19:13 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-28 |
Time |
19:13 |
Sent To |
B |
|
| Notes |
| 2004-07-28 00:00:00 | ********** UNSAT 2ND TIME *********** | | | | | | 1)NOTE: PLEASE SEE PLANS CAME BACK W/ | | | NO CORRECTIONS MADE.?? | | | | | | 2)NOTE: PLEASE SEE COPY OF FS 553.80(2)( | | | B) ATTACHED WITH RESPECT TO DESIGN | | | PROFESSIONAL. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-28 |
Time |
11:42 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-07-16 |
Time |
10:28 |
Sent To |
M |
|
| Notes |
| 2004-07-16 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE 210.52C3,5 FOR MISS- | | | -ING RECEPT ON KITCHEN PENINSULAR. | | | | | | 2)NOTE: PLEASE SEE WASHER SHOWN AS 2-P | | | BRKR? | | | | | | 3)NOTE: PLEASE SEE LOAD CALCUALTIONS | | | FOR PANEL "A". IT APPEAR TO SHOW 20KW | | | FOR A/C LOAD?? | | | | | | 4)NOTE: PLEASE SEE LOAD FOR FRIG IS | | | SHOWN AT 15.0KW. (MISPRINT). | | | | | | 5)NOTE: PLEASE SEE PLANS INDICATE A GFI | | | FOR JACUZZI/WHIRLPOOL TUB, BUT THIS IS | | | NOT SHOWN ON PANEL SCHEDULE OR LOAD | | | CALCULATIONS. | | | | | | 6 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | LOAD CAN ONLY BE INCLUDED IF RECESSED | | | LTS ARE PART OF MIN GEN LT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | PLEASE SEE ONE SET OF PLANS HAVE ITEMS | | | REDLINED. PLEASE ALSO SEE 210.8,210.52 | | | NOTED ON PLANS. | | | PLEASE NOTE: STUDIO WILL BE REQUIRED TO | | | HAVE ARC FAULT PROTECTION AS IT IS | | | CONSIDERED TO BE AN ADAPTABLE FOR | | | SLEEPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-14 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-14 |
Time |
13:36 |
Sent To |
B |
|
| Notes |
| 2005-09-14 00:00:00 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-08 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-08 |
Time |
18:50 |
Sent To |
B |
|
| Notes |
| 2005-09-08 00:00:00 | TO "MISC" BOX#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-22 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-22 |
Time |
11:21 |
Sent To |
E |
|
| Notes |
| 2005-07-22 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-18 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-18 |
Time |
16:02 |
Sent To |
P |
|
| Notes |
| 2005-07-18 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-28 |
Time |
11:42 |
Sent To |
E |
|
| Notes |
| 2004-07-28 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-15 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-07-12 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | TO SFD RACK/E | | 2004-07-12 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-16 |
Time |
10:40 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-07-16 |
Time |
15:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-08-02 |
Time |
10:06 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-08-02 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2005-08-02 00:00:00 | REVISED RISER DIAGRAM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-16 |
Time |
15:20 |
Rev Time |
0.75 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-15 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-15 |
Time |
16:08 |
Sent To |
I |
|
| Notes |
| 2004-07-15 00:00:00 | MUST PULL SEPARATE FOR POOL & SCREEN | | | ENCLOSURE. |
|
|