Plan Review Details - Permit 04070247
Plan Review Stops For Permit 04070247
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-08-18 Cont ID  
Sent By kstevens Date 2004-10-14 Time 07:53 Rev Time 0.50
Received By alange Date 2004-08-18 Time 13:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-14 Cont ID  
Sent By pschmitz Date 2004-07-31 Time 07:49 Rev Time 1.00
Received By alange Date 2004-07-14 Time 08:30 Sent To  
Notes
2004-07-14 00:00:00DENIED
 1.FBC 905.2.1SHOW HOW SMOKE
 DETECTORS WILL COMPLY WITH THIS SECTION.
  
 2.FBC 104.2.1 PRINTED NAME AND
 SIGNATURE OF THE PERSON RESPOSIBLE
 FOR PLANS MUST BE ON PLANS.
  
 3.SHOW MATERIALS USED FOR FRAMING AND
 FIRE BLOCKING.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-08-01 Cont ID  
Sent By dpalmer Date 2005-08-01 Time 06:38 Rev Time 0.50
Received By dpalmer Date 2005-08-01 Time 06:38 Sent To  
Notes
2005-08-01 00:00:00REDLINED STAMPED FOR ARC FAULT
 PROTECTION PER 2002, 210.12

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-19 Cont ID  
Sent By dpalmer Date 2004-08-19 Time 11:18 Rev Time 0.33
Received By dpalmer Date 2004-08-19 Time 11:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-07-12 Cont ID  
Sent By dpalmer Date 2004-07-12 Time 13:14 Rev Time 0.50
Received By dpalmer Date 2004-07-12 Time 13:14 Sent To  
Notes
2004-07-12 00:00:00*********** UNSAT ***************
  
 1)NOTE: PLEASE SHOW CIRCUITING ON PLANS
 WITH PANEL SCHEDULE TO CORRELATE.
 PLEASE SHOW MIN REQUIRED CIRCUITS.
 210.52, BATHS, SM APPLS ETC.
  
 2)NOTE: PLEASE SEE LOCATION OF PANEL IS
 SHOWN FACING INTO BATHRM. PANEL IS NOT
 PERMITTED IN BATH.240.24E
  
 3)NOTE: PLEASE SHOW SD'S ARE REQUIRED
 PER NFPA-72 8-1
  
  
 4 )NOTE: PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CURCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 5)NOTE: PLEASE SEE FBC 104.2.1
 PRINTED NAME AND SIGNATURE OF PERSON
 RESPONSIBLE FOR PLANSMUST BE ON PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-09-01 Cont ID  
Sent By mcarsill Date 2004-09-01 Time 15:32 Rev Time 0.00
Received By mcarsill Date 2004-09-01 Time 15:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-07-29 Cont ID  
Sent By mcarsill Date 2004-07-29 Time 13:38 Rev Time 0.00
Received By mcarsill Date 2004-07-29 Time 13:38 Sent To  
Notes
2004-07-29 00:00:001) EXISTING ELECTRIC POWERED SMOKE
 DETECTORS ARE REQUIRED OUTSIDE OF
 EVERY SLEEPING ROOM. WHEN ACTIVATED,
 THEY SHALL CAUSE AND AUDIBLE ALARM
 IN THE SLEEPING ROOMS.
  
 2) ENTRY DOOR IS REQUIRED TO BE FIRE
 RATED. PLEASE CONFIRM RATING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-08-04 Cont ID  
Sent By adarroug Date 2005-08-04 Time 10:20 Rev Time 0.00
Received By adarroug Date 2005-08-04 Time 10:20 Sent To P
Notes
2005-08-04 00:00:00TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-08-17 Cont ID  
Sent By csiegber Date 2004-08-17 Time 14:24 Rev Time 0.00
Received By csiegber Date 2004-08-17 Time 14:24 Sent To  
Notes
2004-08-17 00:00:00TO COMM BD#21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-31 Cont ID  
Sent By csiegber Date 2004-08-17 Time 14:26 Rev Time 0.00
Received By csiegber Date 2004-07-07 Time 14:05 Sent To  
Notes
2004-07-07 00:00:00TO COMM BD#36

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-07-21 Cont ID  
Sent By pkrauss Date 2004-07-21 Time 07:55 Rev Time 0.35
Received By pkrauss Date 2004-07-21 Time 07:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-08-09 Cont ID  
Sent By kstevens Date 2005-08-09 Time 08:37 Rev Time 0.60
Received By kstevens Date 2005-08-09 Time 08:37 Sent To  
Notes
2005-08-09 00:00:00REVISION OK - SANT. RISER DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-10-14 Cont ID  
Sent By kstevens Date 2004-10-14 Time 07:52 Rev Time 0.33
Received By kstevens Date 2004-10-14 Time 07:52 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-09-16 Cont ID  
Sent By kstevens Date 2004-09-16 Time 11:46 Rev Time 1.50
Received By kstevens Date 2004-09-16 Time 11:45 Sent To  
Notes
2004-09-16 00:00:00DENIED
 REFERENCE: FLORIDA STATUTES
  
 FROM PREVIOUS REVIEW:
  
 FS 481.229(1)(C) ALL WORK OVER $25,000
 REQUIRES A DESIGN PROFESSIONAL.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-31 Cont ID  
Sent By pschmitz Date 2004-07-31 Time 07:49 Rev Time 2.50
Received By pschmitz Date   Time   Sent To  
Notes
2004-07-31 00:00:00PLUMBING PLAN REVIEW FBC 2001 DENIED
 (1) DESIGN PROFESSIONAL REQUIRED ON ANY
 OTHER TYPE OF BUILDING ALTERATION COST-
 ING MORE THAN $25,000.OO, FS 481.229
 (2) SEPERATE APPLICATION FOR DEMOLITION
 PERMIT OF EXISTING UNIT.
 SEE PERMIT FEE SHEET ATTACHED.
 END OF COMMENTS, QUESTIONS CONTACT
 PAUL SCHMITZ 561-805-6692