| Plan Review Stops For Permit 04070210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-07-13 |
Time |
17:30 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-07-16 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-04-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-11 |
Time |
18:38 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-04-11 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2005-04-11 00:00:00 | *** PLANS REDLINED *** | | | IF GENERATOR IS INSTALLED BEFORE FINAL | | | OF MAIN HOUSE, PLANS WILL BE REQUIRED TO | | | BE REVISED TO SHOW INSTALLATION EVEN IF | | | GENERATOR IS UNDER SEPARATE PERMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-01 |
Time |
13:35 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-04-01 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2005-04-01 00:00:00 | ******** UNSAT ************ | | | | | | PLEASE SEE NOTES BELOW, PLEASE SEE SOME | | | NOTES ARE FROM "PROVISO" SETFORTH ON | | | PREVIOUS REVIEW. | | | | | | 1)NOTE: PLEASE SEE MISSING GFI RECEPTS | | | ON KITCHEN ISLAND. | | | 210.52C1,2,5 AND 210.8A6 | | | | | | 2)NOTE: PLEASE SEE AN EQUIPMENT | | | GROUNDING CONDUCTOR IS SHOWN FROM METER | | | TO 125A MAIN. | | | PLEASE SEE 250.6,250.24, THIS IS ONLY | | | INSTALLED AFTER THE FIRST MEANS OF DISC. | | | | | | 3)NOTE: PLEASE SEE WHIRLPOOL/SPA/JUCUZZI | | | TUB IS SHOWN ON PANEL SCHEDULE, HOWEVER | | | PLANS DO NOT INDICATE GFI RECEPT. | | | | | | 4)NOTE: PLEASE SEE PLANS DO NOT SHOW | | | MAINS/ ATS/ GENERATOR ON PLANS. PLEASE | | | SHOW SERVICE EQUIPMENT. | | | "GEN IS UNDER SEPARATE PERMIT | | | APPLICATION. | | | | | | 5)NOTE: PLEASE SEE DISH/DISP SHOWN WITH | | | #6 AWG? PLEASE VERIFY THIS. #6 ON 20A | | | BRKR. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
09:15 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-12 |
Time |
09:15 |
Sent To |
M |
|
| Notes |
| 2004-07-12 00:00:00 | *********** PROVISO/NOTES *********** | | | | | | 1)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS. | | | | | | 2)NOTE: PLEASE SEE 210.52C1,2,5 FOR | | | KITCHEN COUNTER RECEPTS/ISLAND. | | | | | | 3)NOTE: PLEASE SEE PLANS ONLY SHOWN ONE | | | PANEL. PLEASE SHOW BOTH PANELS ON PLANS. | | | | | | 4)NOTE: PLEASE SEE PANEL SCHEDULE SHOWS | | | JACUZZI TUB , HOWEVER PLANS DO NOT SHOW | | | REQUIRED GFI AT TUB LOCATION? | | | | | | PLEASE SUBMIT REVISED PLAN BEFORE ROUGH | | | ELECTRICAL INSPECTION. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-04-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-04-08 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-04-08 |
Time |
10:29 |
Sent To |
E |
|
| Notes |
| 2005-04-08 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-30 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-30 |
Time |
16:24 |
Sent To |
E |
|
| Notes |
| 2005-03-30 00:00:00 | TO "DPALMER" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-08 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-07-07 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2004-07-09 00:00:00 | TO SFD RACK/E | | 2004-07-07 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
09:21 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-07-13 |
Time |
07:23 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-13 |
Time |
07:41 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-07-13 |
Time |
17:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-08 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-08 |
Time |
10:38 |
Sent To |
I |
|
| Notes |
| 2004-07-08 00:00:00 | MUST PULL SEPARATE PERMIT FOR POOL/DECK |
|
|