|
 |
 |
 |
 |
 |
Plan Review Details - Permit 04070189
| Plan Review Stops For Permit 04070189 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-08-04 |
Time |
11:44 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-08-04 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
18:28 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-07-09 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
18:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
18:22 |
Sent To |
B |
|
| Notes |
| 2004-08-03 00:00:00 | REDLINED ** | | | | | | RECEPT SPACING SHOWN FOR KITCHEN COUNTER | | | -SPACE DOES NOT MEET 210.52C1 | | | | | | BATH RECEPT? POWDER RM. | | | 210.52D/210.11C3 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
15:22 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-07-12 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | ******** UNSAT ******** | | | | | | 1)NOTE: PLEASE SHOW RECEPT(S) REQUIRED | | | PER 210.52D/210.11C3 BATHS. | | | | | | 2)NOTE: PLEASE SEE KIT SHOWS NEW LAYOUT, | | | PLEASE INDICATE RECEPT REQUIRED PER | | | 210.52C1-5 | | | PLEASE SHOW RECEPTS TO BE GFI/GFI | | | PROTECTED. 210.8,210.8A6 | | | NOTE MENTIONS TO ADD PLUMOLD TO UPPER | | | CABINETS, YET NONE SHOWN ON PLAN. | | | | | | 3)NOTE: PLEASE SEE FBC 104.2.1, A PRINT- | | | -ED NAME IS ALSO REQUIRED NEXT TO SIGNAT | | | -URE OF PERSON RESPONSIBLE FOR PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-14 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-14 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-29 |
Time |
15:22 |
Sent To |
E |
|
| Notes |
| 2004-07-29 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-27 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2004-07-06 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | TO COMM BD#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-16 |
Time |
15:59 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-07-16 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | NO MECHANICAL WORK OR CONTRACTOR | | | INDICATED ON THE PERMIT APPLICATION OR | | | PLANS SUBMITTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-27 |
Time |
13:40 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2004-07-27 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2004-07-27 00:00:00 | NO PLUMBING PLANS SUBMITTED/REPLACING | | | LAV, CAPPING OFF LINES TO LAV & BAR SINK |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |