| Plan Review Stops For Permit 04070082 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2005-08-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-08-11 |
Time |
12:08 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-08-11 |
Time |
12:08 |
Sent To |
PC |
|
| Notes |
| 2005-08-11 00:00:00 | REVISION STORM SHUTTERS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-08-17 |
Time |
12:06 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-08-17 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-17 |
Time |
11:20 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-07-23 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2004-07-23 00:00:00 | BUILDING PLAN REVIEW (2ND REVIEW) FAILED | | | | | | 1. THERE ARE CHANGES TO THE SIGNED & | | | SEALED PLANS WITHOUT THE ARCHITECT'S | | | SIGNING OFF.NO CHANGES CAN BE MADE TO | | | APPROVED PLANS WITHOUT THE ARCHITECT | | | SIGNING THE CHANGES THAT ARE MADE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-23 |
Time |
14:22 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-07-12 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | A SEPARATE PERMIT IS REQUIRED FOR THE | | | STORM PANELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-03-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-28 |
Time |
10:26 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-28 |
Time |
10:26 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-23 |
Time |
10:15 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-23 |
Time |
10:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-03-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-08 |
Time |
15:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-08 |
Time |
15:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-10 |
Time |
16:30 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-10 |
Time |
16:18 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
16:14 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-23 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2004-07-23 00:00:00 | ********* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE SOME NOTES FROM | | | FIRST REVIEW NEED TO BE FULLY ADDRESSED. | | | | | | 2)NOTE: PLEASE SEE NOTE #4 FROM FIRST | | | REVIEW. ARC FAULT IS NOTED, HOWEVER BOTH | | | PANEL SCHEDULES INDICATESD'S TO KIT | | | AND BATH CIRCUITS?? | | | | | | 3)NOTE: PLEASE SEE CLEARENCE FOR A/C | | | REQUIRED PER 110.26. A/C UNITS HAVE | | | MOVED AND NOW HAVE WALLS. PLEASE SEE | | | PLANS. | | | | | | 4)NOTE: PLEASE SEE NOTE #10 FIRST REVIEW | | | PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | PLEASE SEE LOAD CALCS ON PANEL SCHEDULES | | | DO NOT CORREALATE WITH NEW NOTES ADDED | | | TO PLANS FOR LT LOADS. | | | | | | 5)NOTE: PLEASE SEE THAT WHITE OUT AND | | | CORRECTION MAY NOT BE ADDED TO SIGNED | | | AND SEALED PLANS. THIS COMMENT IS PER | | | FS 481.221. | | | PLEASE MUST BE ORIG. ANY AND ALL CHANGES | | | TO SIGNED AND SEALED PLANS MUST HAVE | | | EACH ITEM , SIGNED AND DATED BY THE | | | ARCH OF RECORD. | | | | | | PLEASE SEE NOTES 1,2, FROM FIRST REVIEW, | | | SUB-PANEL ARE STILL SHOWN AS MCB ALONG | | | WITH MAINS ON OUTSIDE OF HOUSE? | | | 150A PANEL STILL SHOWS 2/0'S,310.15 AND | | | GROUNDING ELECTRODE CONDUCTOR IS NOW | | | SHOWN AS 2/0?250.66 | | | THE ABOVE IS PERMITTED BUT IF SHOWN | | | THIS WAY ON PLANS, THEN THEY WILL BE | | | REQUIRED TO BE INSTALLED UNLESS REVISED | | | PLANS ARE SUBMITTED AND PAY REVISION | | | FEES AT A LATER DATE. THIS IS ONLY A | | | NOTE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
10:19 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-07-07 |
Time |
09:40 |
Sent To |
M |
|
| Notes |
| 2004-07-07 00:00:00 | ************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE RISER AND PANEL | | | -S. PANELS ARE SHOWN AS MCB AND RISER | | | SHOWS MLO? | | | | | | 2)NOTE: PLEASE SEE CONDUCTORS SHOWN FOR | | | 150A DISC'S AND PANELS ARE SHOWN AS | | | 2/0'S. THIS IS PERMITTED AND IS ONLY A | | | NOTE. | | | | | | 3)NOTE: PLEASE SEE 250.50 FOR MISSING | | | FOOTER STEEL AS PART OF THE GE SYSTEM. | | | | | | 4 )NOTE: PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CURCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | PLEASE SEE SD'S ARE NOTED AS BEING | | | WIRED INTO KIT/BATH LT CIRCUITS. | | | | | | 5)NOTE: PLEASE SEE MISSING REQUIRED | | | RECEPT FOR BATH RM. TO BE W/IN 3' OF | | | SINK. 210.52D/210.11C3 | | | | | | 6)NOTE: PLEASE SEE 210.52 FOR SOME | | | RECEPTSMISSING. | | | | | | 7)NOTE: PLEASE CORRELATE LOADS SHOWN | | | FOR AHU'S / AND LOAD CALCULATIONS ALONG | | | WITH OCP. | | | SHOWS 8KW AND 5KW ON ONE . | | | LOADS IN LOAD CALCS? | | | | | | 8)NOTE: PLEASE SEE AN ELECTRICAL WATER | | | HEATER IS SHOWN ON PANEL SCHEDULE AND | | | LOAD CALCS, HOWEVER PLANS ARE SHOWING | | | WH AS GAS?? | | | | | | 9)NOTE: PLEASE SEE 110.26 FOR MIN SPACE | | | FOR A/C CU'S. #'S 1&2."REDLINE ITEM". | | | | | | 10)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 11)NOTE: PLEASE PROVIDE RM DESIGNATION | | | ON PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-10 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-10 |
Time |
15:09 |
Sent To |
P |
|
| Notes |
| 2006-04-10 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-08-08 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-08-08 |
Time |
11:00 |
Sent To |
B |
|
| Notes |
| 2005-08-08 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
16:14 |
Sent To |
E |
|
| Notes |
| 2004-08-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-21 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-21 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2004-07-21 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-20 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-16 |
Time |
16:22 |
Sent To |
Z |
|
| Notes |
| 2004-07-16 00:00:00 | TO MM BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-06 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-07-02 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | TO SFD RACK/E | | 2004-07-02 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-17 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2004-08-17 |
Time |
11:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-10 |
Time |
16:30 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-07-07 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2004-07-07 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW/ENERGY & MANUAL J CALCULATIONS | | | ONLY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-04-11 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-04-11 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2006-04-11 00:00:00 | REVISION REMOVE ICE MAKER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-12 |
Time |
12:56 |
Rev Time |
0.33 |
| Received By |
lsmith |
Date |
2004-07-10 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | PER JL 7/10/04 LS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-20 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-20 |
Time |
16:17 |
Sent To |
I |
|
| Notes |
| 2004-07-20 00:00:00 | DENIED, 2ND REVIEW STILL OVER THE HEIGHT | | | OF 33FT.CALLED CONTR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-16 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-06 |
Time |
12:21 |
Sent To |
I |
|
| Notes |
| 2004-07-06 00:00:00 | DENIED, HOUSE IS OVER THE HEIGHT | | | REQUIRMENT OF 33FT.CALLED CONTR. | | | | | | MUST PULL A SEPARATE PERMIT FOR POOL AND | | | CBS WALL WITH UTILITY APPROVAL. |
|
|