| Plan Review Stops For Permit 04070064 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-10-16 |
Time |
09:56 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-09-01 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2004-09-01 00:00:00 | BUILDING PLAN REVIEW: PROVISO | | | | | | 1. PLANS MUST BE TAKEN TO PBC AND IMPACT | | | FEES PAID.THE PLANS WILL BE STAMPED | | | BY PBC.THIS MUST BE COMPLETE BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2. THE ENERGY FROMS ARE MISSING THE | | | OWNER/AGENT SIGNATURE..PLEASE SIGN AND | | | RETURN ONE COPY TO LEA. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-09-01 |
Time |
07:03 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
2004-07-15 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2004-07-15 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | | | 1. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK OFFICE BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 2. PLANS MUST BE TAKEN TO PALM BEACH | | | COUNTY BUILDING DEPT. AND IMPACT FEES | | | PAID. | | | THE PLANS WILL BE STAMPED BY PBC AND | | | A COPY OF THE RECEIPT & THE STAMPED | | | PLANS MUST BE SUBMITTED BEFORE A PERMIT | | | CAN BE ISSUED. | | | | | | 3. PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | FLORIDA PRODUCT APPROVALS REQUIRED: | | | A. WINDOWS | | | B. FRENCH DOORS | | | C. STRUCTURAL COMPONENTS (TRUSS STRAPS, | | | ETC. | | | D. ROOF MATERIALS | | | E. STORM PANELS (POMA IS NOT LISTED | | | WITH THE STATE OF FLORIDA) | | | F. SKYLIGHTS | | | SUBMIT 2 COPIES OF ALL SUBMITTALS. | | | | | | 4. THE FLORIDA ENERGY EFFICIENCY CODE | | | STATES ONLY 1018 Q. FT. PLANS SHOW: | | | 1ST. FLOOR: A/C 1145 | | | COVERED PORCH 134 | | | 2ND FLOOR: A/C1018 | | | TOTAL A/C 2163 | | | TOTAL OTHER134 | | | GRAND TOTAL2297 | | | FORMS MUST BE SIGNED BY THE PERSON WHO | | | PREPARES IT AND THE OWNER/AGENT. | | | | | | | | | | | | | | | | | | 5. THE POOL WILL REQUIRE A SEPARATE | | | PERMIT. | | | | | | 6. THE SUBCONTRACTORS LISTED ON THE | | | APPLICATION ARE NOT REGISTERED.THEY | | | WILL HAVE TO PULL SEPARATE PERMITS FOR | | | THEIR WORK AND PAY SEPARATE FEES BASED | | | ON THEIR CONTRACT. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-10-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-10-14 |
Time |
17:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-10-14 |
Time |
15:55 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-26 |
Time |
11:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-25 |
Time |
16:12 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-13 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:47 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-07-13 |
Time |
11:37 |
Sent To |
P |
|
| Notes |
| 2004-07-13 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALLED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BE RATED FOR THE AVAILABLE FAULT | | | CURRENT PER 110.9. | | | | | | 2} PLEASE SHOW GROUNDING PER 250.50, | | | ALL AVAILABLE, AND THE GROUNDING | | | ELECTRODE PER 250.66. | | | | | | 3} THE LOAD CALCULATIONS ARE INCORRECT. | | | PLEASE CALCULATE PER 220.31, OPTIONAL, | | | OR 220.3 STANDARD. | | | | | | 4} THE FOLLOWING ITEMS MUST BE | | | CALCUTATED PER THE CORRESPONDING | | | ARTICLES: | | | A) RANGE -220.19 (8000VA) | | | B) DRYER-220.18 (5000VA) | | | C) LAUNDRY-220.16(B) (1500VA) | | | D) SMALL APPLIANCE-220.16(A)-2 EACH AT | | | 1500VA. | | | 5} THE AHU'S MUST BE CALCULATED @ 100% | | | PER 220.31. | | | | | | 6} THE 65% OF THE REMAINDER OF THE LOAD | | | IS INCORRECT PER 220. | | | | | | 7} THE OCP IS TOO LARGE FOR THE | | | CONDUCTORS FOR AHU #2. SEE 310.16. | | | | | | 8} PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED , | | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | | | | | 9} PLEASE LIST ALL THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3. | | | | | | 10} ADDITIONAL RECEPTACLES ARE REQUIRED | | | PER ARTICLE 210.52(A)(1) & (2) IN THE | | | FOLLOWING ROOMS: BILLIARDS, KITCHEN, | | | OFFICE, GUEST BEDROOM(UPSTAIRS). | | | 210.52(C) IN THE KITCHEN. 210.52(D) | | | GUEST BATH, 210.52(E) AT THE REAR OF | | | THE HOUSE. | | | | | | 11} THE RECEPTACLES IN THE KITCHEN MUST | | | COMPLY WITH 210.8(A)(6), GFI. | | | | | | 12} SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | | | | 13} THERE IS A PANEL SHOWN IN THE | | | LAUNDRY ROOM IN VIOLATION OF 110.26. | | | THIS PANEL IS NOT SHOWN ON THE RISER | | | DIAGRAM, PLEASE SHOW SAME AND SUBMIT A | | | PANEL SCHEDULE ON PLANS. | | | | | | IF THERE AR EANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-07-07 00:00:00 | OK PER E STILLINGSDEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-18 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-18 |
Time |
11:11 |
Sent To |
M |
|
| Notes |
| 2005-11-18 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-12 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-12 |
Time |
13:45 |
Sent To |
E |
|
| Notes |
| 2005-10-12 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-21 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-21 |
Time |
19:53 |
Sent To |
M |
|
| Notes |
| 2005-09-21 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-22 |
Time |
14:28 |
Sent To |
P |
|
| Notes |
| 2004-09-22 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-19 |
Time |
16:47 |
Sent To |
E |
|
| Notes |
| 2004-08-19 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-07 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-07 |
Time |
16:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-07 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-01 |
Time |
15:54 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-07 |
Time |
09:55 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-02-07 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | MECH. REV., CORRECTIONS HAVE BEEN MADE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-21 |
Time |
09:10 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2005-11-21 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | *** DENIED *** | | | 1) RETURN AIR DUCT TO BELOW NEEDS TO BE | | | 12", PER 2001 FBC/M 601.4 . | | | 2) RETURN AIR TO MASTER BEDROOM NEEDS TO | | | BE 14"X14" GRILL WITH 12" FLEX, PER 2001 | | | FBC/M 601.4 . | | | 3) RETURN AIR GRILL IN DINING ROOM | | | SHOULD BE 218 SQ. IN. OR LARGER. | | | 4) 8X16 TRUNK LINE FROM FIRST FLOOR DOES | | | NOT GO TO A.H.U. . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-10-17 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-10-17 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2005-09-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-09-22 |
Time |
09:47 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-09-22 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | *** DENIED *** | | | 1) A/C EQUIP. NOT SHOWING ON PLANS FOR | | | ADDITION. | | | 2) NEED MOUNTING INFO. ON AM. STANDARD | | | TCK-018. SHOS COMPLIANCE FOR THE 140 MPH | | | WIND LOAD. | | | 3) AIR DUCT TRUNK LINE SIZES NOT | | | SHOWING. | | | 4) SOME FLEX DUCT SIZES NOT SHOWING, AND | | | CFM'S NOT SHOWING AT GRILLS. | | | 5) NO DRYER VENT SHOWING. SEE 2001 FBC/M | | | 504.6 . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-31 |
Time |
15:58 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-31 |
Time |
15:27 |
Sent To |
B |
|
| Notes |
| 2004-08-31 00:00:00 | PROVISO: | | | PLAN M-1 DOES NOT INDICATE A RETURN AIR | | | THE OFFICE AREA.PROVIDE DUCT SIZE FOR | | | THE SUPPLY DUCT INTO THE OFFICE SPACE. | | | | | | THE CONDENSING UNIT STAND SHALL COMPLY | | | WITH 2001 FBC 1511.7 FOR THE HEIGHT | | | REQUIREMENT FROM THE ROOF SURFACE TO | | | THE BOTTOM OF THE SUPPORT RAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-26 |
Time |
11:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-07-15 |
Time |
13:52 |
Sent To |
B |
|
| Notes |
| 2004-07-15 00:00:00 | DENIED: | | | PER 2001 FBC(M) 601.4, HABITABLE ROOMS | | | SEPARATED BY A DOOR SHALL HAVE RETURN | | | AIR.PLAN SHEET M-1, OFFICE AREA RETURN | | | AIR REQUIRED FROM THIS SPACE. | | | | | | AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | PLAN SHEET M-1, PLEASE CLARIFY MOUNTING | | | OF THE AMERICAN STANDARD TCK018.IS THE | | | LOCATION ON THE FLAT ROOF?PLEASE | | | PROVIDE DETAIL FOR MOUNTING, SHOW | | | COMPLIANCE FOR THE 140 MPH WIND LOAD. | | | HEIGHT REQUIREMENT FROM THE FINISHED | | | ROOF SHALL COMPLY WITH 2001 FBC 1511.7. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-10-16 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2004-10-16 |
Time |
09:53 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
| 2004-10-16 00:00:00 | 2ND FLOOR SANITARY STACK TO TIEIN | | | DOWN STREAM OF KITCHEN SINKS BRANCHES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-22 |
Time |
14:28 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-15 |
Time |
08:23 |
Sent To |
M |
|
| Notes |
| 2004-07-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | | | | 1) SHT M-2 SANITARY RISER DIAGRAM DOES | | | NOT MEET CODE REQUIREMENTS. | | | A) THE KITCHEN ISLAND SINK IS NOT VENT- | | | ED. SECTION 901.2.1 | | | B) THE 2ND FLOOR BATHROOMS SHALL NOT | | | DRAIN THRU THE VENT FOR THE 1ST FLOOR | | | KITCHEN SINK. A SEPARATE STACK IS REQ- | | | UIRED. SECTION 908.3 | | | C) SHOWER & TUB ARE NOT VENTED AS PIPED | | | CONNECT LINE TO SHOWER AND TUB TO VENTED | | | LINE DRAINING THE LAV'S. SECTION 901.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-01 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-07 |
Time |
12:54 |
Sent To |
I |
|
| Notes |
| 2004-07-07 00:00:00 | NEED TO PULL SEPARATE PERMIT FOR POOL. | | | APPROVING FOR RENOVATE EXISTING | | | STRUCTURE & ADDING 2 STORY SOUTH SIDE |
|
|