Plan Review Details - Permit 04070064
Plan Review Stops For Permit 04070064
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-09-01 Cont ID  
Sent By pschmitz Date 2004-10-16 Time 09:56 Rev Time 1.50
Received By lsmith Date 2004-09-01 Time 10:18 Sent To  
Notes
2004-09-01 00:00:00BUILDING PLAN REVIEW: PROVISO
  
 1. PLANS MUST BE TAKEN TO PBC AND IMPACT
 FEES PAID.THE PLANS WILL BE STAMPED
 BY PBC.THIS MUST BE COMPLETE BEFORE A
 PERMIT CAN BE ISSUED.
  
 2. THE ENERGY FROMS ARE MISSING THE
 OWNER/AGENT SIGNATURE..PLEASE SIGN AND
 RETURN ONE COPY TO LEA.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-15 Cont ID  
Sent By pkrauss Date 2004-09-01 Time 07:03 Rev Time 1.50
Received By lsmith Date 2004-07-15 Time 14:58 Sent To  
Notes
2004-07-15 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERK OFFICE BEFORE
 A PERMIT CAN BE ISSUED.
  
 2. PLANS MUST BE TAKEN TO PALM BEACH
 COUNTY BUILDING DEPT. AND IMPACT FEES
 PAID.
 THE PLANS WILL BE STAMPED BY PBC AND
 A COPY OF THE RECEIPT & THE STAMPED
 PLANS MUST BE SUBMITTED BEFORE A PERMIT
 CAN BE ISSUED.
  
 3. PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE
 AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 FLORIDA PRODUCT APPROVALS REQUIRED:
 A. WINDOWS
 B. FRENCH DOORS
 C. STRUCTURAL COMPONENTS (TRUSS STRAPS,
 ETC.
 D. ROOF MATERIALS
 E. STORM PANELS (POMA IS NOT LISTED
 WITH THE STATE OF FLORIDA)
 F. SKYLIGHTS
 SUBMIT 2 COPIES OF ALL SUBMITTALS.
  
 4. THE FLORIDA ENERGY EFFICIENCY CODE
 STATES ONLY 1018 Q. FT. PLANS SHOW:
 1ST. FLOOR: A/C 1145
 COVERED PORCH 134
 2ND FLOOR: A/C1018
 TOTAL A/C 2163
 TOTAL OTHER134
 GRAND TOTAL2297
 FORMS MUST BE SIGNED BY THE PERSON WHO
 PREPARES IT AND THE OWNER/AGENT.
  
  
  
  
  
 5. THE POOL WILL REQUIRE A SEPARATE
 PERMIT.
  
 6. THE SUBCONTRACTORS LISTED ON THE
 APPLICATION ARE NOT REGISTERED.THEY
 WILL HAVE TO PULL SEPARATE PERMITS FOR
 THEIR WORK AND PAY SEPARATE FEES BASED
 ON THEIR CONTRACT.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-10-14 Cont ID  
Sent By btrobaug Date 2005-10-14 Time 17:07 Rev Time 0.50
Received By btrobaug Date 2005-10-14 Time 15:55 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-08-26 Cont ID  
Sent By btrobaug Date 2004-08-26 Time 11:50 Rev Time 0.50
Received By btrobaug Date 2004-08-25 Time 16:12 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-07-13 Cont ID  
Sent By csiegber Date 2004-08-19 Time 16:47 Rev Time 0.75
Received By btrobaug Date 2004-07-13 Time 11:37 Sent To P
Notes
2004-07-13 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING
 INSTALLED. MAINS/BRKRS AND PANELS ARE
 ALL TO BE RATED FOR THE AVAILABLE FAULT
 CURRENT PER 110.9.
  
 2} PLEASE SHOW GROUNDING PER 250.50,
 ALL AVAILABLE, AND THE GROUNDING
 ELECTRODE PER 250.66.
  
 3} THE LOAD CALCULATIONS ARE INCORRECT.
 PLEASE CALCULATE PER 220.31, OPTIONAL,
 OR 220.3 STANDARD.
  
 4} THE FOLLOWING ITEMS MUST BE
 CALCUTATED PER THE CORRESPONDING
 ARTICLES:
 A) RANGE -220.19 (8000VA)
 B) DRYER-220.18 (5000VA)
 C) LAUNDRY-220.16(B) (1500VA)
 D) SMALL APPLIANCE-220.16(A)-2 EACH AT
 1500VA.
 5} THE AHU'S MUST BE CALCULATED @ 100%
 PER 220.31.
  
 6} THE 65% OF THE REMAINDER OF THE LOAD
 IS INCORRECT PER 220.
  
 7} THE OCP IS TOO LARGE FOR THE
 CONDUCTORS FOR AHU #2. SEE 310.16.
  
 8} PLEASE LIST THE REQUIRED ARC
 FAULT PROTECTED CIRCUIT(S) ON PANEL
 SCHEDULE. PLEASE SEE THAT ALL "OUTLETS"
 IN BEDROOMS ARE TO BE PROTECTED ,
 INCLUDING, LTS, RECEPTS, SD'S ETC.
  
 9} PLEASE LIST ALL THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S) ON PANEL
 SCHEDULE. PER 210.52D, 210.11C3.
  
 10} ADDITIONAL RECEPTACLES ARE REQUIRED
 PER ARTICLE 210.52(A)(1) & (2) IN THE
 FOLLOWING ROOMS: BILLIARDS, KITCHEN,
 OFFICE, GUEST BEDROOM(UPSTAIRS).
 210.52(C) IN THE KITCHEN. 210.52(D)
 GUEST BATH, 210.52(E) AT THE REAR OF
 THE HOUSE.
  
 11} THE RECEPTACLES IN THE KITCHEN MUST
 COMPLY WITH 210.8(A)(6), GFI.
  
 12} SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
  
 13} THERE IS A PANEL SHOWN IN THE
 LAUNDRY ROOM IN VIOLATION OF 110.26.
 THIS PANEL IS NOT SHOWN ON THE RISER
 DIAGRAM, PLEASE SHOW SAME AND SUBMIT A
 PANEL SCHEDULE ON PLANS.
  
 IF THERE AR EANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2004-07-07 Cont ID  
Sent By csiegber Date 2004-07-07 Time 16:14 Rev Time 0.00
Received By csiegber Date 2004-07-07 Time 16:14 Sent To  
Notes
2004-07-07 00:00:00OK PER E STILLINGSDEE

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-11-18 Cont ID  
Sent By adarroug Date 2005-11-18 Time 11:11 Rev Time 0.00
Received By adarroug Date 2005-11-18 Time 11:11 Sent To M
Notes
2005-11-18 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2005-10-12 Cont ID  
Sent By adarroug Date 2005-10-12 Time 13:45 Rev Time 0.00
Received By adarroug Date 2005-10-12 Time 13:45 Sent To E
Notes
2005-10-12 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-21 Cont ID  
Sent By adarroug Date 2005-09-21 Time 19:53 Rev Time 0.00
Received By adarroug Date 2005-09-21 Time 19:53 Sent To M
Notes
2005-09-21 00:00:00TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-09-22 Cont ID  
Sent By csiegber Date 2004-09-22 Time 14:28 Rev Time 0.00
Received By csiegber Date 2004-09-22 Time 14:28 Sent To P
Notes
2004-09-22 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-08-19 Cont ID  
Sent By csiegber Date 2004-08-19 Time 16:47 Rev Time 0.00
Received By csiegber Date 2004-08-19 Time 16:47 Sent To E
Notes
2004-08-19 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-07-07 Cont ID  
Sent By csiegber Date 2004-07-07 Time 16:15 Rev Time 0.00
Received By csiegber Date 2004-07-07 Time 16:15 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-01 Cont ID  
Sent By mmclean Date 2004-07-07 Time 12:54 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 15:54 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2006-02-07 Cont ID  
Sent By tgordon Date 2006-02-07 Time 09:55 Rev Time 0.30
Received By tgordon Date 2006-02-07 Time 09:55 Sent To  
Notes
2006-02-07 00:00:00MECH. REV., CORRECTIONS HAVE BEEN MADE.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2005-11-21 Cont ID  
Sent By tgordon Date 2005-11-21 Time 09:10 Rev Time 0.35
Received By tgordon Date 2005-11-21 Time 09:10 Sent To  
Notes
2005-11-21 00:00:00*** DENIED ***
 1) RETURN AIR DUCT TO BELOW NEEDS TO BE
 12", PER 2001 FBC/M 601.4 .
 2) RETURN AIR TO MASTER BEDROOM NEEDS TO
 BE 14"X14" GRILL WITH 12" FLEX, PER 2001
 FBC/M 601.4 .
 3) RETURN AIR GRILL IN DINING ROOM
 SHOULD BE 218 SQ. IN. OR LARGER.
 4) 8X16 TRUNK LINE FROM FIRST FLOOR DOES
 NOT GO TO A.H.U. .
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2005-10-17 Cont ID  
Sent By pkrauss Date 2005-10-17 Time 07:14 Rev Time 0.00
Received By pkrauss Date 2005-10-17 Time 07:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2005-09-22 Cont ID  
Sent By tgordon Date 2005-09-22 Time 09:47 Rev Time 0.30
Received By pkrauss Date 2005-09-22 Time 09:47 Sent To  
Notes
2005-09-22 00:00:00*** DENIED ***
 1) A/C EQUIP. NOT SHOWING ON PLANS FOR
 ADDITION.
 2) NEED MOUNTING INFO. ON AM. STANDARD
 TCK-018. SHOS COMPLIANCE FOR THE 140 MPH
 WIND LOAD.
 3) AIR DUCT TRUNK LINE SIZES NOT
 SHOWING.
 4) SOME FLEX DUCT SIZES NOT SHOWING, AND
 CFM'S NOT SHOWING AT GRILLS.
 5) NO DRYER VENT SHOWING. SEE 2001 FBC/M
 504.6 .
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-09-01 Cont ID  
Sent By pkrauss Date 2004-08-31 Time 15:58 Rev Time 0.35
Received By pkrauss Date 2004-08-31 Time 15:27 Sent To B
Notes
2004-08-31 00:00:00PROVISO:
 PLAN M-1 DOES NOT INDICATE A RETURN AIR
 THE OFFICE AREA.PROVIDE DUCT SIZE FOR
 THE SUPPLY DUCT INTO THE OFFICE SPACE.
  
 THE CONDENSING UNIT STAND SHALL COMPLY
 WITH 2001 FBC 1511.7 FOR THE HEIGHT
 REQUIREMENT FROM THE ROOF SURFACE TO
 THE BOTTOM OF THE SUPPORT RAIL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-07-15 Cont ID  
Sent By btrobaug Date 2004-08-26 Time 11:50 Rev Time 0.35
Received By pkrauss Date 2004-07-15 Time 13:52 Sent To B
Notes
2004-07-15 00:00:00DENIED:
 PER 2001 FBC(M) 601.4, HABITABLE ROOMS
 SEPARATED BY A DOOR SHALL HAVE RETURN
 AIR.PLAN SHEET M-1, OFFICE AREA RETURN
 AIR REQUIRED FROM THIS SPACE.
  
 AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 PLAN SHEET M-1, PLEASE CLARIFY MOUNTING
 OF THE AMERICAN STANDARD TCK018.IS THE
 LOCATION ON THE FLAT ROOF?PLEASE
 PROVIDE DETAIL FOR MOUNTING, SHOW
 COMPLIANCE FOR THE 140 MPH WIND LOAD.
 HEIGHT REQUIREMENT FROM THE FINISHED
 ROOF SHALL COMPLY WITH 2001 FBC 1511.7.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-10-16 Cont ID  
Sent By pschmitz Date 2004-10-16 Time 09:53 Rev Time 1.00
Received By pschmitz Date   Time   Sent To B
Notes
2004-10-16 00:00:002ND FLOOR SANITARY STACK TO TIEIN
 DOWN STREAM OF KITCHEN SINKS BRANCHES.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-15 Cont ID  
Sent By csiegber Date 2004-09-22 Time 14:28 Rev Time 0.50
Received By kstevens Date 2004-07-15 Time 08:23 Sent To M
Notes
2004-07-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
  
 1) SHT M-2 SANITARY RISER DIAGRAM DOES
 NOT MEET CODE REQUIREMENTS.
 A) THE KITCHEN ISLAND SINK IS NOT VENT-
 ED. SECTION 901.2.1
 B) THE 2ND FLOOR BATHROOMS SHALL NOT
 DRAIN THRU THE VENT FOR THE 1ST FLOOR
 KITCHEN SINK. A SEPARATE STACK IS REQ-
 UIRED. SECTION 908.3
 C) SHOWER & TUB ARE NOT VENTED AS PIPED
 CONNECT LINE TO SHOWER AND TUB TO VENTED
 LINE DRAINING THE LAV'S. SECTION 901.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-07-07 Cont ID  
Sent By csiegber Date 2004-07-01 Time 15:54 Rev Time 0.00
Received By mmclean Date 2004-07-07 Time 12:54 Sent To I
Notes
2004-07-07 00:00:00NEED TO PULL SEPARATE PERMIT FOR POOL.
 APPROVING FOR RENOVATE EXISTING
 STRUCTURE & ADDING 2 STORY SOUTH SIDE