Plan Review Details - Permit 04061323
Plan Review Stops For Permit 04061323
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-10-25 Cont ID  
Sent By lsmith Date 2004-10-25 Time 09:56 Rev Time 0.50
Received By lsmith Date 2004-10-25 Time 09:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-23 Cont ID  
Sent By lsmith Date 2004-07-23 Time 11:07 Rev Time 0.50
Received By lsmith Date 2004-07-23 Time 11:07 Sent To  
Notes
2004-07-23 00:00:00BUILDING PLAN REVIEW: FAILED:
  
 1. SEE ELECTRICAL & PLUMBING NOTES
  
 2. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERK'S OFFICE AND
 A COPY SUBMITTED BEFORE A PERMIT CAN BE
 ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-08 Cont ID  
Sent By dpalmer Date 2004-10-08 Time 06:21 Rev Time 0.25
Received By dpalmer Date 2004-10-08 Time 06:14 Sent To  
Notes
2004-10-08 00:00:00**REDLINED 2002 NEC.**

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-07-02 Cont ID  
Sent By dpalmer Date 2004-07-02 Time 17:21 Rev Time 0.33
Received By dpalmer Date 2004-07-02 Time 17:21 Sent To  
Notes
2004-07-02 00:00:00****** UNSAT *********
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A PANEL SCHED-
 -ULE TO BE SUBMITTED.
 PLEASE ALSO SHOW ALL MIN REQUIRED CIR-
 -CUITS FOR NEW WORK. PER 2002 NEC
  
 2)NOTE: PLEASE SEE 2002 NEC FOR REQUIRED
 ARC FAULT PER 210.12
  
 3)NOTE: PLEASE SEE PANEL MAY NOT BE IN
 BATH ROOM. APPEARS TO BE SHOWN IN
 MASTER BATH??240.24E
  
 PLEASE SEE NOTES FROM OTHER REVIEWERS
 AS THEY MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS.
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW SHEETS INTO COMPLETE
 SETS FOR REVIEW AND STAMPING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-11-01 Cont ID  
Sent By nmccray Date 2004-11-01 Time 14:24 Rev Time 0.00
Received By nmccray Date 2004-11-01 Time 14:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-11-01 Cont ID  
Sent By mwennerg Date 2004-07-22 Time 15:38 Rev Time 0.00
Received By nmccray Date 2004-07-22 Time 14:05 Sent To  
Notes
2004-07-22 00:00:001) PLEASE PROVIDE A DOOR SCHEDULE.
 2) PLEASE PROVIDE INFORMATION REGARDING
 INTERIOR FINISH.
 3) PLEASE SHOW HOW THIS WORK IMPACTS
 THE EXISTING FIRE SPRINKLER AND FIRE
 ALARM SYSTEMS.
  
 A/CAPT. MIKE WENNERGREN
 WPBFR (561) 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-10-07 Cont ID  
Sent By csiegber Date 2004-10-07 Time 07:46 Rev Time 0.00
Received By csiegber Date 2004-10-07 Time 07:46 Sent To  
Notes
2004-10-07 00:00:00TO COMM BD#11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-05 Cont ID  
Sent By csiegber Date 2004-10-05 Time 15:27 Rev Time 0.00
Received By csiegber Date 2004-10-05 Time 15:27 Sent To  
Notes
2004-10-05 00:00:00TO COMM BD#

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-23 Cont ID  
Sent By lsmith Date 2004-07-23 Time 11:09 Rev Time 0.00
Received By lsmith Date 2004-06-29 Time 14:24 Sent To  
Notes
2004-06-29 00:00:00TO COMM BD#47

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2004-07-16 Cont ID  
Sent By pkrauss Date 2004-07-16 Time 14:44 Rev Time 0.15
Received By pkrauss Date 2004-07-16 Time 14:44 Sent To  
Notes
2004-07-16 00:00:00NO MECHANICAL PLANS OR CONTRACTOR
 INDICATED.PLAN SHEET A-1 INDICATS
 RELOCATION OF RETURN AIR GRILLE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-10-18 Cont ID  
Sent By kstevens Date 2004-10-18 Time 15:36 Rev Time 0.75
Received By kstevens Date 2004-10-18 Time 15:36 Sent To  
Notes
2004-10-18 00:00:00PASSED/PROVISO
  
 FIELD INSPECTOR SHALL VERIFY LISTING FOR
 TUB - MANUF INSTALLATION REQUIRED AT THE
 TIME OF ROUGH INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-20 Cont ID  
Sent By kstevens Date 2004-07-20 Time 08:42 Rev Time 0.50
Received By kstevens Date 2004-07-20 Time 08:42 Sent To  
Notes
2004-07-20 00:00:00DENIED
 REFERENCE: FBC-2001 CHAPTER 1
 FBC-2001 PLUMBING
  
 1) SUBMIT A SANITARY & WATER RISER DIA-
 GRAM FOR PLUMBING IN NEW LOCATION.
 SECTION 104.3.1.1
 2) SUBMIT MANUF. INFORMATION ON "WALK-IN
 TUB" FOR PRODUCT APPROVAL AND TO SEE HOW
 IT WILL BE INSTALLED.
 3) ALL DEMO'D/CAPPED PLUMBING SHALL BE
 INSPECTED PRIOR TO COVERING.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]