| Plan Review Stops For Permit 04061323 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-10-25 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-10-25 |
Time |
09:56 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-10-25 |
Time |
09:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-23 |
Time |
11:07 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2004-07-23 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2004-07-23 00:00:00 | BUILDING PLAN REVIEW: FAILED: | | | | | | 1. SEE ELECTRICAL & PLUMBING NOTES | | | | | | 2. A NOTICE OF COMMENCEMENT MUST BE | | | FILED AT THE COUNTY CLERK'S OFFICE AND | | | A COPY SUBMITTED BEFORE A PERMIT CAN BE | | | ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-08 |
Time |
06:21 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-10-08 |
Time |
06:14 |
Sent To |
|
|
| Notes |
| 2004-10-08 00:00:00 | **REDLINED 2002 NEC.** |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-02 |
Time |
17:21 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-02 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | ****** UNSAT ********* | | | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL SCHED- | | | -ULE TO BE SUBMITTED. | | | PLEASE ALSO SHOW ALL MIN REQUIRED CIR- | | | -CUITS FOR NEW WORK. PER 2002 NEC | | | | | | 2)NOTE: PLEASE SEE 2002 NEC FOR REQUIRED | | | ARC FAULT PER 210.12 | | | | | | 3)NOTE: PLEASE SEE PANEL MAY NOT BE IN | | | BATH ROOM. APPEARS TO BE SHOWN IN | | | MASTER BATH??240.24E | | | | | | PLEASE SEE NOTES FROM OTHER REVIEWERS | | | AS THEY MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-11-01 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-11-01 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-11-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2004-07-22 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-07-22 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | 1) PLEASE PROVIDE A DOOR SCHEDULE. | | | 2) PLEASE PROVIDE INFORMATION REGARDING | | | INTERIOR FINISH. | | | 3) PLEASE SHOW HOW THIS WORK IMPACTS | | | THE EXISTING FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | A/CAPT. MIKE WENNERGREN | | | WPBFR (561) 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
07:46 |
Sent To |
|
|
| Notes |
| 2004-10-07 00:00:00 | TO COMM BD#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2004-10-05 00:00:00 | TO COMM BD# |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-07-23 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-06-29 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | TO COMM BD#47 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-07-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-16 |
Time |
14:44 |
Rev Time |
0.15 |
| Received By |
pkrauss |
Date |
2004-07-16 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2004-07-16 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED.PLAN SHEET A-1 INDICATS | | | RELOCATION OF RETURN AIR GRILLE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-18 |
Time |
15:36 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-10-18 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2004-10-18 00:00:00 | PASSED/PROVISO | | | | | | FIELD INSPECTOR SHALL VERIFY LISTING FOR | | | TUB - MANUF INSTALLATION REQUIRED AT THE | | | TIME OF ROUGH INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-20 |
Time |
08:42 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-07-20 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2004-07-20 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 PLUMBING | | | | | | 1) SUBMIT A SANITARY & WATER RISER DIA- | | | GRAM FOR PLUMBING IN NEW LOCATION. | | | SECTION 104.3.1.1 | | | 2) SUBMIT MANUF. INFORMATION ON "WALK-IN | | | TUB" FOR PRODUCT APPROVAL AND TO SEE HOW | | | IT WILL BE INSTALLED. | | | 3) ALL DEMO'D/CAPPED PLUMBING SHALL BE | | | INSPECTED PRIOR TO COVERING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|