| Plan Review Stops For Permit 04061202 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-26 |
Time |
09:32 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-01-26 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2006-01-26 00:00:00 | REVISED PAGE 2 OK FOR KITCHEN |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-08-30 |
Time |
09:58 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2004-08-30 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2004-08-26 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2004-08-26 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2004-08-26 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | | | 1) FBC 1606.1.4THE SUBMITTED WINDOW | | | AND FRENCH DOOR PRODUCT APPROVALS ARE | | | FOR PRODUCTS WITH NO IMPACT RATING. | | | SUBMIT PRODUCT APPROVAL FOR HURRICANE | | | MISSILE IMPACT PROTECTION SHUTTERS OR | | | FOR IMPACT RATED DOORS AND WINDOWS. | | | | | | 2) FBC 13-103.0ENERGY CODE COMPLIANCE | | | SHALL BE DEMONSTRATED BY SUBMITTAL OF | | | APPROPRIATE CODE COMPLIANCE FORMS.TWO | | | BLANK COPIES OF FORM 600C HAVE BEEN | | | SUPPLIED FOR COMPLETION AND SUBMITTAL. | | | | | | 3) FBC 1403.2.2.1CROSS-SECTION A-A | | | DOES NOT SHOW ANY SUPPORT FOR THE | | | MASONRY VENEER.ANCHORED MASONRY VENEER | | | SHALL BE VERTICALLY SUPPORTED ON | | | FOOTINGS, FOUNDATION WALLS OR OTHER | | | APPROVED NON-COMBUSTIBLE STRUCTURAL | | | ELEMENTS.AMEND/ANNOTATE THE PLANS. | | | | | | 4) FBC 1403.2.4THE NOTE, ON CROSS- | | | SECTION A-A, ABOUT MASONRY VENEER TIES | | | SHALL BE AMENDED TO STATE THE TYPE AND | | | SPACING OF THE TIES.MASONRY VENEER | | | ANCHORED TO WOOD FRAMING SHALL BE | | | ATTACHED WITH METAL TIES EMBEDDED IN THE | | | MORTAR JOINT A MINIMUM OF ONE-HALF OF | | | THE VENEER THICKNESS.EACH METAL TIE | | | SHALL SUPPORT NOT MORE THAN 3 SQFT OF | | | WALL AREA WITH A MAXIMUM SPACING OF 18" | | | VERTICALLY AND 32" HORIZONTALLY.ALSO, | | | A MINIMUM OF 1" AIR SPACE SHALL BE | | | MAINTAINED BETWEEN THE ANCHORED VENEER | | | AND THE EXTERIOR FACE OF THE SHEATHING. | | | ANNOTATE THE PLANS TO DEMONSTRATE | | | COMPLIANCE. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6716ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-24 |
Time |
11:19 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2004-08-11 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2004-08-11 00:00:00 | DENIED | | | SUBMIT 2 COPIES OF ALL PRODUCT | | | APPROVALSDEPARTMENT OF COMMUNITY | | | AFFAIRSAPPROVAL SHEETS ARE EITHER WRONG | | | OR | | | INCOMPLETE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | IF YOU HAVE QUETIONS OR WOULD LIKE TO | | | MEET WITH ME GIVE ME A CALL. | | | | | | ART LANGE | | | BUILDING PLAN REVIEW | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-10 |
Time |
14:38 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-07-21 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2004-07-21 00:00:00 | DENIED | | | SAME NOTES AS LAST REVIEW: | | | | | | SUBMMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR EXTERIOR DOORS AND WINDOWS. IMPACT | | | PROTECTION AND ROOFING. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-19 |
Time |
17:58 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-07-12 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2004-07-12 00:00:00 | DENIED | | | 1.SUBMIT 2 COPIES OF PRODUCT APPROVALS | | | FOR EXTERIOR DOORS AND WINDOWS. | | | IMPACT PROTECTION AND ROOFING. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-02 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-02 |
Time |
12:31 |
Sent To |
PC |
|
| Notes |
| 2006-05-02 00:00:00 | ********* UNSAT *********** | | | | | | 1) NOTE: PLEASE SEE TWO SEPARATE | | | ELECTRICAL RISERS ARE NOW BEING | | | SUBMITTED. | | | ONE INDICATES BEING FOR 626 FRANKLIN AND | | | THE OTHER FOR 826 FRANKLIN. | | | PLEASE ONLY SUBMIT ONE FOR REVIEW. | | | PLEASE SEE ONE RISER SHOWS #6 FOR GEC | | | AND #4, PLEASE SEE 250.66, AS THE #4 IS | | | REQUIRED AT A MIN. | | | | | | 2) NOTE: PLEASE ALSO EACH RISER CONTAINS | | | DIFFERENT PERSONS RESPONSIBLE FOR DESIGN | | | PLEASE SEE THE ORIGINAL PERSON | | | RESPONSIBLE FOR DESIGN SHOULD BE THE | | | PERSON OF RECORD , UNLESS ALL PLANS ARE | | | BEING CHANGED TO THE NEW DESIGN | | | PROFESSIONAL OF RECORD. | | | FBC104.2.1 | | | PLEASE SEE IN ANY CASE ALL PLANS, WHEN | | | NOT ORIGINALLY DONE BY AN ARCHITECT OR | | | ENGINEER, SHALL CONTAIN THE PRINTED NAME | | | AND SIGNATURE. | | | | | | 3) NOTE: PELASE SEE PREVIOUS NOTE | | | MENTIONED THE DEDICATE BATH CIRCUIT | | | SHALL BE 20A AND #12, THIS WAS CORRECTED | | | TO #12, HOWEVER IS NOW ALSO PENCILED AS | | | #14? | | | PLEASE KNOW, ONLY 20A AND #12 IS | | | PERMITTED. | | | | | | 4) NOTE: PLEASE SEE ONE PLANS INDICATES | | | ELECTRICAL FOR ALL APPLIANCES, WHERE THE | | | OTHER SHOWS GAS FOR SOME. | | | PLEASE CORRELATE AND SUBMIT ONLY ONE. | | | 215.5 | | | | | | 5) NOTE; PLEASE SEE THE PLANS CAME IN AS | | | A SUBMITTIAL WHEN INDEED IT WAS A | | | REVISION. PLEASE SEE A FEE IS OWED FOR | | | THIS REVIEW AND ALSO FOR REVISION WHEN | | | PLANS ARE BROUGHT BACK. | | | PLEASE BE SURE TO ADDRESS ALL COMMENTS | | | AND IF THERE ARE ANY QUESTIONS, PLEASE | | | DO NOT HESITATE IN CONTACTING THIS | | | OFFICE TO HELP ALLEAVIATE ANY FURTHER | | | DELAYS/REVIEWSOR FEES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-17 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-17 |
Time |
08:17 |
Sent To |
P |
|
| Notes |
| 2006-01-17 00:00:00 | *********UNSAT ********** | | | | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE HAD ALL | | | REQUIRED SMOKE DETECTORS AND GFI'S FOR | | | EXISTING DWELLING REMOVED.???? | | | PLEASE SEE ORIGINAL PLANS WHICH | | | INDICATED THIS. | | | FBC CHAPTER 34 FOR ADDTIONS TO EXISTING | | | DWELLINGS. | | | PLEASE CORRECT PLANS. | | | | | | 2)NOTE: PLEASE CORRELATE PANEL SCHEDULE | | | ALONG WITH LOAD CALCUALTIONS SUBMITTED. | | | PLEASE SEE DRYER SHOWN AS 5KW ON A | | | 1-POLE 20 ETC. | | | PLEASE SEE AHU #2 AS 30A OCP #10 AWG | | | WITH 10 KW RATING ON CALCS.(424.3). | | | PLEASE SEE MISSING MICROWAVE. | | | ETC. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE MIN OCP FOR DOUBLE | | | OVEN AND COOKTOP SHALL BE BASED ON MIN | | | OCP FOR KW RATINGS. PLEASE SEE A 10KW | | | LOAD IS BEING SHOWN ON 40A OCP WHICH | | | EXCEEDS MIN RATINGS OF DEVICE AND BRKR. | | | 240.4, 215.5 | | | | | | 4)NOTE: PLEASE SEE 210.52D,210.11C3 | | | WHICH REQUIRES BATH RECEPT(S) TO BE ON A | | | MIN 20A, #12 AWG CIRCUIT. | | | | | | 5)NOTE: PLEASE INDICATE THE REQUIRED GFI | | | PROTECTION FOR THE JACUZZI TUB,680.71 | | | | | | 6)NOTE: PLEASE SEE 210.52C1 FOR WHAT | | | APPEARS TO BE A MISSING KITCHEN | | | COUNTERSPACE RECEPT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-24 |
Time |
11:19 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-24 |
Time |
11:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
10:43 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-08-10 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
| 2004-08-10 00:00:00 | ************* UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE PLANS ARE NOW BEING | | | SUBMITTED WITH REFERENCE TO SERVICE AS | | | BEING A NEW 200A SERVICE. PLEASE SEE | | | NOTE #4 FROM PREVIOUS REVIEW WHICH | | | REQUESTED AIC RATING FOR NEW SERVICE | | | MAIN/EQIPMENT. PER 110.9/215.5 | | | PLEASE SHOW LOCATION OF NEW PANEL. | | | | | | 2)NOTE: PLEASE SEE PLANS ARE ALSO NOW | | | BEING SUBMITTED SHOWING ALL NEW ELECTR- | | | -ICAL IN REMAINDER OF HOUSE? | | | IF ELECTRICAL NOW SHOWN FOR EXISTING | | | DWELLINGIS EXISTING, PLEASE LABEL W/ | | | AN "E" OR NOTE. AS SHOWN, EXISTING | | | DWELLING IS BEING REWIRED? | | | | | | 3) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210.8A-6 | | | | | | 4)NOTE: PLEASE SEE PANEL/LOAD CALCS | | | INDICATE TWO A/C SYSTEMS YET PLANS ONLY | | | SHOW ONE COND UNIT AND AHU? | | | | | | PLEASE SEE SOME NOTES ARE NEW DUE TO | | | PLANS BEING CHANGED TO SHOW NEW ITEMS. | | | AIC RATING WAS REQUESTED ON PREVIOUS | | | REVIEW FOR SERVICE (IF NEW). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
13:43 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-19 |
Time |
17:57 |
Sent To |
B |
|
| Notes |
| 2004-07-19 00:00:00 | ************* UNSAT *************** | | | | | | 1)NOTE: PLEASE CORRELATE PANEL SCHEDULE | | | AND LOAD CALCULATIONS. THERE ARE MANY | | | ITEMS THAT DO NOT MATCH. | | | PLEASE SEE AHU KW RATING SHOWN AS 10KW | | | W/60OCP AND 30A OCP? 424.3B | | | PLEASE SEE WATER HEATER, DISP,DISHW ETC. | | | | | | 2)NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | MUST BE 20A #12. | | | | | | NOTE: OK | | | | | | | | | | | | 4)NOTE: PLEASE CLARIFY IF SERVICE IS | | | NEW OR EXSITING? METER IS SHOWN AS EXIST | | | -ING BUT PANEL DO NOT INDICATE. IF NEW | | | SUBMIT AIC RATING FOR EQUIPMENT PER | | | 110.9. | | | PLEASE ALSO SEE MISSING EQUIPMENT GROUND | | | -ING CONDUCTOR PER 250.110,250.24, | | | 250.122 | | | | | | 5)NOTE: PLEASE SEE FBC CHAPTER 34 FOR | | | ADDITIONS TO EXISTING DWELLINGS. | | | PLEASE PROVIDE LAYOUT FOR NEW OR EXIST- | | | -ING SD'S , GFI'S ETC. | | | 3401.7.1.2.1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-15 |
Time |
16:02 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2004-06-30 |
Time |
10:37 |
Sent To |
M |
|
| Notes |
| 2004-06-30 00:00:00 | 1)NEED LOAD CALCULATION | | | | | | 2)ALL OUTLETS IN THE BEDROOMS TO ARC | | | FAULT PROTECTED | | | | | | 3)NEED A PANEL SCHEDULE | | | | | | 4)SMOKE DETECTORS ARE TO BE ALEAST 3' | | | FROM BATH ROOM AND AC VENTS | | | | | | ANY QUESTIONS CALL JAKE805-6740 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-26 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-26 |
Time |
12:18 |
Sent To |
E |
|
| Notes |
| 2006-04-26 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-06 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-06 |
Time |
17:12 |
Sent To |
E |
|
| Notes |
| 2006-01-06 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-19 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
| 2004-08-19 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-03 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-03 |
Time |
13:43 |
Sent To |
E |
|
| Notes |
| 2004-08-03 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-15 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-15 |
Time |
16:02 |
Sent To |
E |
|
| Notes |
| 2004-07-15 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-29 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-29 |
Time |
15:07 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-29 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
09:27 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2004-06-30 |
Time |
10:40 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-07-08 |
Time |
07:27 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-24 |
Time |
15:21 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-24 |
Time |
15:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-07-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-08 |
Time |
07:34 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-07-10 |
Time |
12:52 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-29 |
Time |
12:13 |
Sent To |
I |
|
| Notes |
|
|