Plan Review Details - Permit 04060897
Plan Review Stops For Permit 04060897
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2005-10-04 Cont ID  
Sent By shill Date 2005-10-04 Time 20:03 Rev Time 0.00
Received By shill Date 2005-10-04 Time 20:03 Sent To  
Notes
2005-10-04 00:00:00WINDOW REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2005-08-10 Cont ID  
Sent By shill Date 2005-08-10 Time 13:41 Rev Time 0.00
Received By shill Date 2005-08-10 Time 13:41 Sent To  
Notes
2005-08-10 00:00:00TRUSS ENGINEERING

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2005-03-29 Cont ID  
Sent By shill Date 2005-03-29 Time 16:06 Rev Time 0.00
Received By shill Date 2005-03-29 Time 13:40 Sent To  
Notes
2005-03-29 00:00:00PRECAST SHOPS PREPARED BY BRAD CASH, PE
 ALL BUILDINGS ON ONE SUBMITTAL, FILED
 WITH 04060859
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2005-01-19 Cont ID  
Sent By shill Date 2005-01-19 Time 11:48 Rev Time 0.00
Received By shill Date 2005-01-19 Time 11:48 Sent To PC
Notes
2005-01-19 00:00:00PROVISO - AT RISK PERMIT

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2005-01-05 Cont ID  
Sent By shill Date 2005-01-05 Time 09:11 Rev Time 4.00
Received By shill Date 2005-01-05 Time 09:11 Sent To  
Notes
2005-01-05 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)A NOTICE OF COMMENCEMENT WILL BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PROVIDE THE IMPACT FEE RECEIPT.
  
 3.)SHEET S3-2 SHOWS DESIGN PRESSURES
 HIGHER THAN PRODUCT LIMITATIONS.
 PLEASE
 ADDRESS.PLEASE NOTE THAT LOWER
 PRESSURES ARE INDICATED ON S1.2.IF
 SHEET S3-2 IS REMOVED, PLEASE SUBMIT A
 LETTER FROM THE ENGINEER THAT THIS IS
 ACCEPTABLE AND THAT THE LOWER DESIGN
 PRESSURES SHOWN ON S1.2 ARE TO BE USED.
  
 4.)WHILE THE OTHER PRODUCTS ARE
 COMPLIANT WITH THE WORST CASE PRESSURES
 SHOWN ON S1.2, THE GARAGE DOOR IS NOT.
 PLEASE ADDRESS.
  
 5.)STATE OR LOCAL PRODUCT APPROVALS
 REQUIRED IN ADDITION TO TEST REPORTS.
 I
 HAVE OBTAINED THE STATE PRODUCT
 APPROVAL
 NUMBER FOR YOU FOR MOST OF THE
 PRODUCTS.
 THE MULLIONS AND SINGLE HUNG WINDOW
 HAVE
 LOCAL PRODUCT APPROVAL, SEE ATTACHED.
 A
 COPY SHOULD BE PLACED ON THE TOP OF
 EACH
 NOA (S/H AND MULLION ONLY).
  
 6.)PLEASE NOTE THAT THE ROOF PRODUCT
 IS COMPLIANT FOR THIS BUILDING BUT
 WOULD
 NOT BE COMPLIANT FOR THE BUILDINGS WITH
 A MEAN ROOF HEIGHT OF >33'; SEE PAGE 2
 OF PRODUCT APPROVAL, ITEM 4.2.
  
 7.)SEE PREVIOUS LIST, #32, WINDOW
 BUCK
 TO GIVE FULL SUPPORT OF THE WINDOW,
 FBC1707.4.4.2 (A7).
  
 8.)THE FIREBLOCK DETAIL FOR THE 2 HR
 SEPARATION IS NOT FOR 2 HOURS; 80
 MINUTES WAS PROVIDED.THE SOFFIT AND
 FASCIA ARE TO BE FIRE RETARDANT WOOD 4'
 ON EACH SIDE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-12-03 Cont ID  
Sent By shill Date 2004-12-03 Time 12:45 Rev Time 1.00
Received By shill Date 2004-11-30 Time 09:42 Sent To PC
Notes
2004-11-30 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)ENTRY VESTIBULE FOR EACH UNIT IS
 OUTSIDE THE LOT LINE OF THE BUILDING.
  
 3.)SEPARATE PERMITS REQUIRED FOR
 TRADES.
  
 4.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED
 AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 5.)ADDITIONAL FEES DUE (VALUE
 ADJUSTMENT, RADON).SEE ATTACHED.
  
 6.)SUBMIT MULLION PRODUCT APPROVALS.
  
 7.)FLORIDA STATE OR LOCAL PRODUCT
 APPROVALS REQUIRED FAC9B72.
 WWW.FLORIDABUILDING.ORG
  
 8.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 9.)ENERGY CALC 9A SHOULD STATE COMMON
 WALL, 4.2.
  
 10.) BALCONY GUARDRAIL 3-A6 SHOWS THE
 POST EMBEDDED IN A CONCRETE SLAB,
 10-S2.2 AND FLOOR FRAMING PLAN SHOWS
 THIS BALCONY AS HOLLOW CORE.
  
 11.)2-A5 SHOWS THE EDGE OF THE HOLLOW
 CORE BEARING ON THE 2 HR PARTITION
 BLOCK
 WALL.SHOW HOW THE STRUCTURAL AND FIRE
 RESISTANCE IS MAINTAINED PER
 FBC704.4.2.
 THIS DETAIL CONFLICTS WITH THE
 STRUCTURALS (SHOWS CONCRETE TOPPING
 THROUGH THE WALL).
  
 12.)SEE PREVIOUS LIST, #31, PROVIDE
 INFORMATION TO SHOW HOW THE HOLLOW CORE
 PLAN WILL HANDLE THE LINE LOAD OF THE
 CMU WALLS.
  
 13.)SEE PREVIOUS LIST, #32 WINDOW
 BUCK
 TO GIVE FULL SUPPORT OF THE WINDOW,
 FBC1707.4.4.2 (A7).
  
 14.)A RESIDENT INSPECTOR REQUIRED DUE
 TO THE SCOPE AND NATURE OF THIS
 PROJECT.
 PLEASE CONTACT HAROLD PISKURA.
  
 15.)PROVIDE A DETAIL FOR THE 2 HR
 SEPARATION OF UNITS THROUGH THE SOFFIT
 AREA.
  
 16.)PLEASE PROVIDE A SURVEY.A PLAT
 WAS PROVIDED BUT A SURVEY IS ALSO
 REQUIRED.
  
 17.)FBC1007.3.1(1), SUM OF TWO RISERS
 AND A TREAD TO BE 24-25", ENTRY
 VESTIBULE, A2.MANY UNITS ARE NOT IN
 COMPLIANCE; PLEASE CHECK ALL UNITS.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-07-21 Cont ID  
Sent By shill Date 2004-07-21 Time 17:41 Rev Time 1.00
Received By shill Date 2004-07-21 Time 17:41 Sent To  
Notes
2004-07-21 00:00:00SEE 04060887

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-10-28 Cont ID  
Sent By dpalmer Date 2004-10-28 Time 07:26 Rev Time 0.33
Received By dpalmer Date 2004-10-28 Time 07:26 Sent To  
Notes
2004-10-28 00:00:002002 NEC REDLINED

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-06-24 Cont ID  
Sent By dpalmer Date 2004-06-24 Time 14:43 Rev Time 0.25
Received By dpalmer Date 2004-06-24 Time 14:43 Sent To  
Notes
2004-06-24 00:00:00PLEASE SEE NOTES UNDER # 04060892

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2005-01-10 Cont ID  
Sent By nmccray Date 2005-01-10 Time 13:07 Rev Time 0.00
Received By nmccray Date 2005-01-10 Time 13:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-11-23 Cont ID  
Sent By nmccray Date 2004-11-23 Time 15:18 Rev Time 0.00
Received By nmccray Date 2004-11-23 Time 15:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2004-06-23 Cont ID  
Sent By mcarsill Date 2004-06-23 Time 10:37 Rev Time 0.00
Received By mcarsill Date 2004-06-23 Time 10:37 Sent To  
Notes
2004-06-23 00:00:00PLEASE SEE PERMIT # 04060892 FOR
 COMMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-09-12 Cont ID  
Sent By adarroug Date 2005-09-12 Time 08:56 Rev Time 0.00
Received By adarroug Date 2005-09-12 Time 08:56 Sent To B
Notes
2005-09-12 00:00:00TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-05-05 Cont ID  
Sent By adarroug Date 2005-05-05 Time 08:53 Rev Time 0.00
Received By adarroug Date 2005-05-05 Time 08:52 Sent To B
Notes
2005-05-05 00:00:00TO "SHILL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-30 Cont ID  
Sent By mjacobs Date 2004-12-30 Time 10:21 Rev Time 0.00
Received By mjacobs Date 2004-12-30 Time 10:21 Sent To B
Notes
2004-12-30 00:00:00TO "SH" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-10-14 Cont ID  
Sent By csiegber Date 2004-10-14 Time 11:42 Rev Time 0.00
Received By csiegber Date 2004-10-14 Time 11:42 Sent To  
Notes
2004-10-14 00:00:00TO COMM BD#21/PLANS ON RACK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-07-21 Cont ID  
Sent By shill Date 2004-07-21 Time 17:42 Rev Time 0.00
Received By shill Date 2004-06-18 Time 12:30 Sent To  
Notes
2004-06-18 00:00:00TO COMM BD#24

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2005-10-18 Cont ID  
Sent By tgordon Date 2005-10-18 Time 13:06 Rev Time 0.30
Received By tgordon Date 2005-10-18 Time 13:06 Sent To  
Notes
2005-10-18 00:00:00MECH. REV. PLANS AND E. CAL. .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-11-18 Cont ID  
Sent By pkrauss Date 2004-11-18 Time 13:24 Rev Time 0.35
Received By pkrauss Date 2004-11-18 Time 13:24 Sent To  
Notes
2004-11-18 00:00:00PROVISO:BUILDING 3 UNIT 12
 GENEVA END UNIT
 THE EXHAUST FAN SCHEDULE INDICATED ON
 PLAN SHEET M-4 SHOWS EF-2 & EF-3 FOR THE
 KITCHEN AND GARAGE AREAS WHICH ARE NOT
 INDICATED ON THE PLAN.PLEASE CLARIFY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2004-07-20 Cont ID  
Sent By pkrauss Date 2004-07-20 Time 08:46 Rev Time 0.35
Received By pkrauss Date 2004-07-20 Time 08:45 Sent To  
Notes
2004-07-20 00:00:00DENIED:"GENEVA MODEL" END-UNIT
 1.PROVIDE OUTSIDE AIR CALCULATIONS PER
 2001 FBC(M) 402.2, 402.2.1 OR 403.3.
  
 2.AUXILIARY DRAIN PAN WITH OVERFLOW
 PROTECTION REQUIRED PER 2001 FBC(M)
 307.2.3.
  
 3.PLANS ARE TO BE SIGNED AND DATED BY
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE HVAC SYSTEM IN ACCORDANCE WITH THE
 FLORIDA STATUTES AND THE FLORIDA
 ADMINISTRATIVE CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-11-12 Cont ID  
Sent By kstevens Date 2004-11-12 Time 16:03 Rev Time 0.25
Received By kstevens Date 2004-11-12 Time 16:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-07-19 Cont ID  
Sent By kstevens Date 2004-07-19 Time 13:55 Rev Time 0.25
Received By kstevens Date 2004-07-19 Time 13:55 Sent To  
Notes
2004-07-19 00:00:00DENIED
 REFERENCE: FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 ENGINEERS SHALL LEGIBLY INDICATE THEIR
 NAME, ADDRESS AND LICENSE NUMBER ON EACH
 SHEET. IF PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS, ENGIN-
 EERS, ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME AND LICENSE NUMBER, AS WELL
 AS, THE NAME, ADDRESS AND CERTIFICATE OF
 AUTHORIZATION NUMBER OF THE ENGINEERING
 BUSINESS ON EACH SHEET. A TITLE BLOCK
 WILL SATISFY THIS REQUIREMENT. FAC
 61G15-23.002(2) - FS 471.025
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-10-25 Cont ID  
Sent By eschneid Date 2004-10-25 Time 14:42 Rev Time 0.25
Received By eschneid Date 2004-10-25 Time 14:42 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2004-06-30 Cont ID  
Sent By mmclean Date 2004-06-30 Time 11:38 Rev Time 0.00
Received By mmclean Date 2004-06-30 Time 11:38 Sent To  
Notes
2004-06-30 00:00:00 
 DENIED, NEED TO PROVIDE PLAT WITH 41
 LOTS WITH ENGINEERING PLANS (2 SETS).
 NEED TO PROVIDE LANDSCAPE PLANS. CALL
 ERIC SCHNEIDER, SENIOR PLANNER AT 659-
 8031 FOR ANY QUESTIONS.