Plan Review Details - Permit 04060776
| Plan Review Stops For Permit 04060776 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2004-06-25 |
Time |
16:15 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2004-06-25 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-19 |
Time |
09:25 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-07-19 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-07-14 |
Time |
09:08 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-06-17 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2004-06-17 00:00:00 | *********** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE ONLY ONE SHEET OF | | | EACH E0.1 IS IN ONE SET AND ONLY ONE | | | SHEET E2.1 IN OTHER SET. | | | PLEASE SUBMIT TWO COMPLETE SETS. | | | | | | 2)NOTE: PLEASE SUBMIT LOAD CALCULATION | | | FOR EXSITING PANEL SBA.215.5 | | | | | | 3)NOTE: PLEASE VERIFY MEANS OF DISC AT | | | ATS, PER 230.76, 230.79 | | | | | | 4)NOTE: PLEASE SEE PANEL BOARD ON SEC | | | SIDE OF TRANSFORMER IS SHOWN AS MLO, | | | PLEASE SEE 408-16D, 240-21C1 ETC MCB | | | REQUIRED. | | | | | | 3NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42,210.19A,210.20A ETC | | | | | | 4)NOTE: PLEASE INCLUDE LOCATION OF | | | PANEL "H". IS THIS A HOUSE PANEL OR | | | PANEL TO THIS SPACE. | | | PLEASE ALSO SHOW SIZE OF EXSITING PANELS | | | "D". | | | | | | 5)NOTE: PLEASE SEE LICENSE # ON TITLE | | | BLOCK IS NOT CORRECT. PLEASE SEE DBPR. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-19 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-28 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-18 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-18 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | 1) SUBMIT COMPLETE SETS OF PLANS. | | | PAGE(S) ARE MISSING FROM WHAT WAS | | | SUBMITTED. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-19 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-19 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2004-07-19 00:00:00 | TO COMM BD#19 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-07-14 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-07-14 |
Time |
09:07 |
Sent To |
E |
|
| Notes |
| 2004-07-14 00:00:00 | SENT TO "DP" DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-16 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2004-06-16 |
Time |
16:22 |
Sent To |
PC |
|
| Notes |
| 2004-06-16 00:00:00 | TO COMM BD #42 |
|
|
|