| Plan Review Stops For Permit 04060707 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-03-25 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-03-25 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | 3/25/05 CHANGED DESIGNERS OF RECORD FROM | | | JEFFERY D. BRASSEUR, AR TO HARVEY E. | | | KOEHNEN, PE. SEE LETTER IN FILE. | | | SUBMITTED NEW SET OF PLANS SIGNED AND | | | SEALED BY NEW ENGINEER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2005-02-23 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2005-02-23 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2005-02-23 00:00:00 | BUILDING DENIED | | | | | | 1) THE SIGNATURE OF THE ARCHITECT WILL | | | HAVE TO BE NOTARIZED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-12-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-12-30 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-12-30 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2004-12-30 00:00:00 | BUILDING DENIED | | | | | | 1) REVISION FEES ARE REQUIRED FOR ALL 13 | | | PLAN SHEETS. | | | | | | 2) DESIGNER OF RECORD WILL BE CHANGED | | | FROM THE ARCHITECT TO THE ENGINEER. | | | | | | 3) SHEET 4, SHEET 10 AND SHEET 11 HAVE | | | BEEN REVISED AND ARE OK. | | | | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-09-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-09-01 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-09-01 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2004-09-01 00:00:00 | PROVISO | | | | | | SUBMIT PRODUCT APPROVALS FOR DOUBLE | | | ENTRY DOOR AND SWINGING DOOR AT GARAGE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
15:26 |
Rev Time |
4.00 |
| Received By |
rmcdouga |
Date |
2004-07-02 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | DENIED | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) THE ENGINEER IS REQUIRED TO SIGN AND | | | SEAL THE PLAN SHEETS ON WHICH HIS TITLE | | | BLOCK APPEARS. SEE FS 471. | | | | | | 3) FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 4) FBC 2405.2 REQUIRES WINDOWS WITHIN 3' | | | HORIZONTALLY OF A TUB OR SHOWER TO HAVE | | | SAFETY GLASS. SEE WINDOWS IN MASTER BATH | | | | | | 5) SPECIFY THE SIZE AND LOCATION OF THE | | | ATTIC ACCESS ON THE SECOND FLOOR. SEE | | | FBC 2309.6. | | | | | | 6) REVISE NOTE 11 ON SHEET 2. CITY | | | AMENDMENTS TO FBC TABLE 2306.1 REQUIRES | | | 8D RING-SHANK NAILS FOR ROOF SHEATHING | | | IN ZONE 3 ON STRUCTURES WITH A MEAN ROOF | | | HEIGHT OF 25'-35'. | | | | | | 7) PROVIDE A DOOR BUCK DETAIL. NOTE 13 | | | ON SHEET 2 DOES NOT SPECIFY DOOR BUCKS. | | | | | | 8) SPECIFY THAT THE GUARDRAIL ON SHEET 3 | | | MUST REJECT A 4" SPHERE PER FBC 1015.3. | | | | | | 9) FBC 1007.5 REQUIRES STAIRWAYS TO HAVE | | | A HANDRAIL NOT LESS THAN 34" NOR MORE | | | THAN 38" ABOVE THE LEADING EDGE OF A | | | TREAD. SEE FBC 1007.5.3 FOR GRASPABILITY | | | REQUIREMENTS. | | | | | | 10)SPECIFY THE REQUIRED DESIGN PRESSURES | | | FOR THE WINDOWS ON SHEET 4. | | | | | | 11)SPECIFY THE R-VALUE OF THE INSULATION | | | AT THE BLOCK WALLS. MUST CORRESPOND WITH | | | THE ENERGY CALCS. | | | | | | 12) SPECIFY THE LOCATIONS AND MATERIALS | | | USED FOR THE DRAFTSTOPPING AT THE FLOOR/ | | | CEILING ASSEMBLY DIVIDING THE AREA INTO | | | AREAS OF 500 SQFT OR LESS PER FBC 2305.2 | | | AND 2305.2.6. | | | | | | 13) SPECIFY THE BOTTOM CORD LIVE LOAD ON | | | THE PLANS. SEE FBC TABLE 1604.1. | | | | | | 14) SPECIFY THE CONNECTORS USED TO | | | ATTACH THE BOTTOM CORD OF THE ROOF | | | TRUSSES TO THE LEDGERS. | | | | | | 15) SPECIFY THE CONNECTORS FOR ATTACHING | | | THE FLOOR TRUSSES TO THE LEDGERS. | | | | | | 16) SPECIFY THE FIREBLOCKING OF THE | | | CONCEALED SPACES BETWEEN STRINGERS AT | | | THE STAIRS AT THE TOP AND BOTTOM OF RUNS | | | PER FBC 2305.1.4. | | | | | | 17) SPECIFY THE FIREBLOCKING OF THE | | | FURRED SPACE AT THE EXTERIOR WALLS WHERE | | | THEY MEET CEILINGS ON THE WALL SECTIONS | | | PER FBC 2305.1.4. | | | | | | 18) SUBMIT DETAILS FOR FIREPLACE AND | | | CHIMNEY. SPECIFICATIONS AND LISTING IF | | | THEY ARE PREFAB. PROVIDE DETAILED | | | DRAWINGS OF DIMENSIONS, MATERIALS, | | | ATTACHMENTS, CONNECTORS, ETC. FOR FIRE- | | | PLACE AND CHIMNEY. SPECIFY THE HEIGHT | | | ABOVE ROOF FOR THE CHIMNEY AS PER FBC | | | 2804. | | | | | | 19) FBC 1606.1.4 REQUIRES PROTECTION OF | | | GLAZED OPENINGS. SUBMIT STORM PANEL | | | PRODUCT APPROVAL, KEY PLAN AND INSTALLA- | | | TION SCHEDULE OR PRODUCT APPROVALS FOR | | | LARGE MISSLE IMPACT RESISTANT GLASS. | | | | | | 20) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE SAMPLE | | | WITH NOAS. | | | | | | 21) SUBMIT STATE OR LOCAL PRODUCT | | | APPROVALS FOR THE FOLLOWING: | | | - ARCHED TOP WINDOWS (DESIGNER SHAPES) | | | - ENTRY DOORS | | | - SIDE SWING DOOR AT GARAGE | | | - OVER HEAD GARAGE DOOR | | | - STORM PANELS | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-06-15 |
Time |
12:59 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-06-15 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2005-06-15 00:00:00 | ************ UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE GEN IS REQUIRED TO BE | | | SUBMITTED UNDER SEPARATE PERMIT. | | | PLEASE INCLUDE ALL INFORMATION AS | | | REQUIRED FOR GEN PERMIT SUBMITTAL. | | | | | | PLEASE ALSO NOTE PLANS FOR MAIN/ORIG | | | WILL ALSO BE REQUIRED TO BE REVISED | | | AFTER PERMIT FOR GEN HAS BEEN OBTAINED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-10 |
Time |
17:17 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-03-10 |
Time |
17:17 |
Sent To |
P |
|
| Notes |
| 2005-03-10 00:00:00 | REDLINED 220.16 | | | | | | REDLINED NO MORE THAN 8' OF UNPROTECTED | | | CONDUCTORS INSIDE HOUSE. 230.70 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-02-14 |
Time |
14:04 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-02-14 |
Time |
13:39 |
Sent To |
P |
|
| Notes |
| 2005-02-14 00:00:00 | ******** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE REDLINES FROM | | | PREVIOUS REVIEWS. | | | | | | 2)NOTE: PLEASE SEE OCP ON PANEL FOR | | | WHIRLPOOL 30A ON #12. | | | | | | 3)NOTE: PLEASE SEC'S TO BE SIZED PER | | | 310.15B6, 240.4. MIN 400 MCM | | | | | | 4)NOTE: PLEASE SEE GUTTER SIZING PER 366 | | | SHOWS 3"? | | | | | | 5)NOTE: PLEASE SEE FBC 104.2.1, WHICH | | | REQUIRES THE PRINTED NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR PLANS. | | | REQUIRED FOR ALL | | | | | | 6)NOTE: PLEASE ALSO SEE MISSING FOOTER | | | STEEL REQUIRED AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM. 250.50 | | | | | | 7)NOTE: PLEASE SEE LETTER FROM ARCHITECT | | | IS ALSO REQUIRED TO BE NOTORIZED. | | | | | | PLEASE SEE PLANS REQUIRE A REVISION FEE | | | FOR REVISED SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2004-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-12-22 |
Time |
17:04 |
Rev Time |
0.40 |
| Received By |
dpalmer |
Date |
2004-12-22 |
Time |
17:04 |
Sent To |
P |
|
| Notes |
| 2004-12-22 00:00:00 | *********** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE PLANS FOR ELECTRICAL | | | HAVE NOT CHANGED DESIGNER/ENGINEER/ARCH | | | OF RECORD. | | | PLEASE SEE PLANS HOWEVER DO HAVE CHANGES | | | MADE AND CONTRACTOR OWES REV FEES. | | | THIS FEE MAY BE ADJUSTED TO DUE OTHER | | | REVIEWS AND POSSIBLE CHANGES TO OTHER | | | SHEETS ALSO. | | | | | | 2)NOTE: PLEASE SUBMIT A NOTORIZED LETTER | | | FOR THE RELEASE OF PREVIOUS ARCH. | | | | | | 3)NOTE: PLEASE SUBMIT COMPLETED PLANS | | | FOR CODE COMPLIANCE. PLEASE SEE ORIG | | | NOTES REDLINED ON PLANS. SOME OF THESE | | | ITEMS HAVE BEEN CHANGED AND SOME HAVE | | | NOT. | | | | | | PLEASE SEE OTHER COMMENTS FROM OTHER | | | REVIEWS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
09:26 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-08-23 |
Time |
09:11 |
Sent To |
P |
|
| Notes |
| 2004-08-23 00:00:00 | *** NOTES REDLINED. *** | | | | | | SOME ITEMS FOR LOAD AND OCP WERE RED- | | | -LINED ON PANEL SCHEDULE. | | | | | | GUTTER SIZE TO METT NEC 366. | | | | | | GEC SHOWN TO SLAB, 250.50 REQUIRED TO | | | FOOTER STEEL. | | | | | | A COUPLE OF RECEPTS MISSING FOR 2' OF | | | WALL SPACE PER 210.52. REDLINED. | | | | | | SEC'S PER 310.15B6,240.4B |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
16:21 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-06-23 |
Time |
10:11 |
Sent To |
M |
|
| Notes |
| 2004-06-23 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ON EACH LEVEL OF A MULTI-LEVEL DWELLING | | | UNIT. | | | IN CLOSE PROXIMITY OF STAIRWAYS LEADING | | | TO FLOORS ABOVE AND IN THE VICINITY OF | | | BEDROOMS. | | | PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE | | | A MIN OF 3' FROM BATHROOM DOORS AND | | | KITCHENS. | | | ABOVE PER:FBC 905.2, NFPA-72 8-1.4 | | | PLEASE ALSO SEE ADAPTABLE RMS W/ CLOSETS | | | OR BATHS ATTACHED. | | | | | | 2) NOTE: PLEASE LIST ALL THE REQ'D | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 3) NOTE: PLEASE SEE 210.52C1,2,3 FOR | | | RECEPT SPACING IN KITCHENS.THERE ARE A | | | COUPLE MISSING. WALL/ PENINSULAR. | | | | | | 4 )NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | PER PER 220.30 | | | PLEASE SEE LOAD FOR SUB-PANEL MUST BE | | | FIGURED AND THEN ADDED TO MAIN PANEL. | | | PLEASE SEE OTHER NOTES PERTAINING TO MIN | | | LOADS FOR LAUNDRY ETC. | | | | | | 5)NOTE: PLEASE SEE 220.16B, ETC | | | FOR LAUNDRY LOAD MIN. | | | | | | 6)NOTE: PLEASE CORRELATE LOAD/OCP FOR | | | PUMPS ON PANEL SCHEDULE. | | | | | | 7)NOTE:PLEASE SEE LOAD SHOWN ON PANEL | | | "B" SCHEDULE DOES NOT CORRELATE WITH | | | LOAD SHOWN ON PANEL "A" FOR PANEL "B". | | | | | | 8)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS PER 2002 NEC | | | 210.12. THIS IS FOR ALL ITEMS IN BEDRMS. | | | SD'S , LTS, FANS, RECEPTS. | | | | | | 9)NOTE: PLEASE INDICATE REQUIRED GFI | | | PROTECTION FOR WHIRLPOOL TUB. 680 | | | | | | 10)NOTE: PLEASE SEE SIZE OF DISCONNECT | | | AND OCP FOR CU-3, SHOWS 65A DISC AND 65A | | | OCP. PLEASE SEE PANEL SCHEDULE.? | | | | | | 11)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS ON RISER. | | | PANEL 'A' TO PANEL 'B' AND A/C EQUIP. | | | 210.110,250.122 | | | | | | 12)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | | CONDUCTOR PER 250.66 | | | | | | 13)NOTE: PLEASE SEE MISSING GROUNDING | | | ELECTRODE ATTACHMENT TO FOOTER STEEL | | | AS REQUIRED UNDER 250.50. | | | | | | 14)NOTE: PLEASE SEE MISSING SEC'S SIZE | | | FROM METER TO MAIN PANEL. | | | PLEASE ALSO LABEL SIZE OF METER CAN. | | | | | | 15)NOTE:PLEASE VERIFY SIZE OF CONDUCTOR | | | SHOWN FOR 30A COOKTOP. SHOWS #6 FOR THIS | | | UNLESS SOME SORT OF ADAPTER IS USED, | | | #6 WILL NOT FIT A 2P30A BRKR. | | | PLEASE VERIFY. | | | | | | 16)NOTE: PLEASE SEE 210.52 FOR REQUIRED | | | RECEPT SPACING IN HOUSE. THERE ARE A | | | NUMBER OF MISSING RECEPTS. PLEASE SEE | | | ONE SET OF PLANS HAS MOST OF THEM | | | REDLINED, BUT EXACT LOCATIONS ARE NOT | | | SPECIFIED. PLEASE ALSO SEE LEISURE "RM" | | | RAILING AREA IS CONSIDERED "WALL SPACE" | | | AND WILL REQUIRE RECEPTS PER 210.52. | | | | | | 17)NOTE: PLEASE SEE 210.52D, GFI RECEPT | | | FOR BATHS ARE REQUIRED TO BE WITHIN | | | 3' OF THE EDGE OF SINK. PLEASE SEE | | | "HER" BATH AREA. | | | | | | 18)NOTE: PLEASE SEE FS 471, 481.FAC | | | 61G15-23 | | | PLEASE SEE PLANS THAT CONTAIN A TITLE | | | BLOCK OF AN ARCH/ ENGINEERMUST BE | | | SIGNED, DATED AND SEALED BY THAT | | | ENGINEER/ OR ARCH. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO TWO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD MAY BE REQUIRED FOR | | | REFERENCE BY SOME PLAN REVIEWERS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-06-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-06-08 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-06-08 |
Time |
09:31 |
Sent To |
E |
|
| Notes |
| 2005-06-08 00:00:00 | TO 'DP' DESK/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-09 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-09 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2005-03-09 00:00:00 | TO "DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-02-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-02-08 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2005-02-08 |
Time |
16:35 |
Sent To |
E |
|
| Notes |
| 2005-02-08 00:00:00 | TO "E" BOX/SUBMITTALS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-12-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-14 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-14 |
Time |
10:19 |
Sent To |
E |
|
| Notes |
| 2004-12-14 00:00:00 | SENT TO "DP" DESK/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-12 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-12 |
Time |
15:02 |
Sent To |
B |
|
| Notes |
| 2004-11-12 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-20 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-20 |
Time |
16:21 |
Sent To |
E |
|
| Notes |
| 2004-08-20 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-20 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
16:53 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-22 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-06-18 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | TO SFD RACK/E | | 2004-06-18 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-02-23 |
Time |
09:21 |
Rev Time |
0.50 |
| Received By |
prafter |
Date |
2005-02-23 |
Time |
09:21 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-26 |
Time |
15:25 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-08-26 |
Time |
15:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-23 |
Time |
15:38 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-24 |
Time |
12:51 |
Sent To |
P |
|
| Notes |
| 2004-06-24 00:00:00 | PROVISO: | | | 1.RETURN AIR JUMPER FROM BEDROOM #2 | | | SHALL BE A MINIMUM OF 12" PER THE | | | REVISED 2001 FBC(M) 601.4 EXCEPTION #1. | | | | | | 2.RETURN AIR REQUIRED FROM THE 1ST | | | FLOOR DEN/TV ROOM. | | | | | | 3.AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-03-22 |
Time |
17:24 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-03-22 |
Time |
17:24 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2005-02-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-02-23 |
Time |
06:43 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2005-02-23 |
Time |
06:42 |
Sent To |
M |
|
| Notes |
| 2005-02-23 00:00:00 | REVISION DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | A) COMMENTS FROM PREVIOUS REVIEW OF | | | REVISIONS: | | | 1) SEE RED LINE CORRECTIONS ON ORIGINAL | | | SHEET 13. PLEASE MAKE THESE CORRECTIONS | | | AND SUBMIT AS A REVISION AS REQUIRED BY | | | PROVISO. | | | 2) THERE ARE 2 SHEET 13 OF 13 IN EACH | | | SET OF PLANS. PLEASE REMOVE EXTRA SHEETS | | | FORM EACH SET OF PLANS. SECTION | | | 104.2.1. | | | 3) SUBMIT A NOTORIZED LETTER FOR THE | | | RELEASE OF PREVIOUS ARCHITECT AND | | | SHOWING NEW ENGINEER ACCEPTING | | | RESPONSIBLITY FOR PLANS. | | | **************NEW COMMENT************ | | | 1B) FEES DUE FOR REVISION AND MUST BE | | | PAID PRIOR TO NEXT REVIEW FOR THIS | | | REVIEW. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-28 |
Time |
13:06 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-12-28 |
Time |
13:06 |
Sent To |
B1 |
|
| Notes |
| 2004-12-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) SEE RED LINE CORRECTIONS ON ORIGINAL | | | SHEET 13. PLEASE MAKE THESE CORRECTIONS | | | AND SUBMIT AS A REVISION AS REQUIRED BY | | | PROVISO. | | | 2) THERE ARE 2 SHEET 13 OF 13 IN EACH | | | SET OF PLANS. PLEASE REMOVE EXTRA SHEETS | | | FORM EACH SET OF PLANS. SECTION | | | 104.2.1. | | | 3) SUBMIT A NOTORIZED LETTER FOR THE | | | RELEASE OF PREVIOUS ARCHITECT AND | | | SHOWING NEW ENGINEER ACCEPTING | | | RESPONSIBLITY FOR PLANS. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-23 |
Time |
15:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-23 |
Time |
15:36 |
Sent To |
M |
|
| Notes |
| 2004-08-23 00:00:00 | | | | | | | | | | PASSED/PROVISO | | | | | | REVISION REQUIRED - SANT. RISER DIAGRAM | | | SHALL REFLECT THE INSTALLATION OF PIPE | | | SEE RED LINE CORRECTION FOR LAUNDRY ROOM | | | PIPING | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | O |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-23 |
Time |
09:26 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2004-06-28 |
Time |
18:21 |
Sent To |
B |
|
| Notes |
| 2004-06-28 00:00:00 | DENIED; | | | 1.SEE ELECTRICAL PLAN REVIEW NOTE # 18. | | | 2.W/M AND L/T ARE REQUIRED TO DISCHARGE | | | DOWN STREAM OF BATHROOM GROUP. 909.1. | | | 3.PLEASE SEE RISER DIAGRAM MARKED IN RED | | | AND MAKE REQUIRED CHANGES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
REV |
REVISIONS |
| Rev No |
1 |
Status |
N |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-11-19 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-11-19 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2004-11-19 00:00:00 | DENIED | | | | | | REVISED SHEETS ARE NOT SIGNED AND SEALED | | | BY THE DESIGNER OF RECORD. THE ARCHITECT | | | JEFFERY D. BRASSEUR SIGNED AND SEALED | | | THE PLAN SHEETS THAT ARE ON | | | FILE,THEREFORE HE IS REQUIRED TO SIGN | | | AND SEAL ANY REVISIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-20 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-20 |
Time |
14:52 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-08-20 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-08-20 |
Time |
10:41 |
Sent To |
I |
|
| Notes |
| 2004-08-20 00:00:00 | DENIED, OVER THE HOUSE HEIGHT REQ. OF | | | 30FT.NEED TO REDUCE HEIGHT.CALLED | | | CONTRACTOR MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-22 |
Time |
15:47 |
Sent To |
I |
|
| Notes |
| 2004-06-22 00:00:00 | DENIED, OVER THE HEIGHT REQUIREMENT OF | | | 33FT.CALLED & LEFT MSG ON VOICE MAIL. |
|
|