| Plan Review Stops For Permit 04060556 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-11 |
Time |
16:28 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-11 |
Time |
16:28 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-18 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | PROVISO: | | | TRANSFER GRILLE FROM BEDROOM WITH 300 | | | CFM OF SUPPLY AIR, PER THE REVISED 2001 | | | FBC(M) 601.4 EXCEPTION #2 - TRANSFER | | | GRILLES SHALL USE 50 SQ IN OF GRILLE | | | AREA TO 100 CFM OF SUPPLY AIR.PLEASE | | | SIZE TRANSFER GRILLE ACCORDINGLY. | | | | | | AUXILIARY DRAIN PAN WITH OVERFLOW | | | PROTECTION REQUIRED PER 2001 FBC(M) | | | 307.2.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
|