Plan Review Details - Permit 04060532
Plan Review Stops For Permit 04060532
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-06-28 Cont ID  
Sent By kstevens Date 2004-06-25 Time 11:21 Rev Time 0.50
Received By lsmith Date 2004-06-28 Time 09:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-06-16 Cont ID  
Sent By mjacobs Date 2004-06-14 Time 15:43 Rev Time 0.25
Received By btrobaug Date 2004-06-16 Time 14:15 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-02 Cont ID  
Sent By csiegber Date 2004-07-02 Time 13:28 Rev Time 0.00
Received By csiegber Date 2004-07-02 Time 13:28 Sent To P
Notes
2004-07-02 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-14 Cont ID  
Sent By mjacobs Date 2004-06-14 Time 15:43 Rev Time 0.00
Received By mjacobs Date 2004-06-14 Time 15:43 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-11 Cont ID  
Sent By mmclean Date 2004-06-14 Time 11:49 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 15:25 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-07-16 Cont ID  
Sent By kstevens Date 2004-07-16 Time 17:09 Rev Time 0.75
Received By kstevens Date 2004-07-16 Time 17:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-07-02 Time 13:28 Rev Time 1.25
Received By kstevens Date 2004-06-25 Time 11:21 Sent To B
Notes
2004-06-25 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FBC-2001 CHAPTER 1
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 2) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 3) 104.6.5 BUILDING PERMIT VALUATION. IF
 IN THE OPINION OF THE BUILDING OFFICIAL
 THE CLAIMED VALUATION OF BUILDING, AL-
 TERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED, UNLESS THE
 APPLICANT CAN SHOW DETAILED ESTIMATES
 AND/OR BONA FIDED SIGNED CONTRACTS (EX-
 CLUDING LAND VALUE) TO MEET THE APPROVAL
 OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION FOR BUILDINGS AND
 SYSTEMS SHALL BE FOUND IN MARSHALL AND
 SWIFT OR THE SOUTHERN BUILDING CODE
 CONGRESS INTERNATIONAL VALUATION TABLES,
 LATEST EDITION, AND SHALL BE BASED ON
 TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHAN-
 ICAL, INTERIOR FINISH, NORMAL SITE WORK
 (EXCAVATION AND BACKFILL FOR BUILDINGS),
 ARCHITECTURAL AND DESIGN FEES, OVERHEAD
 AND PROFIT, EXCLUDING ONLY LAND VALUE.
 - CALCULATED VALUATION $ 32,925.00 -
 FEES DUE $284.82
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-06-11 Time 15:25 Rev Time 0.00
Received By mmclean Date 2004-06-14 Time 11:49 Sent To I
Notes
***NONE***