Plan Review Details - Permit 04060487
| Plan Review Stops For Permit 04060487 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-22 |
Time |
15:06 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-06-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-06 |
Time |
08:29 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-07-06 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-15 |
Time |
08:43 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-15 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | ************* UNSAT ****************** | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A SUBMITTED | | | PANEL SCHEDULE. PLEASE SHOW NEW AND | | | OR EXSITNG TIE-INS FOR CIRCUITS. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | 3)NOTE: PLEASE INCLUDE ALL LICENSE #'S | | | ON TITLE BLOCK. THIS IS TO INCLUDE THE | | | REQUIRED CERTIFICATE OF AUTHORIZATION | | | PER FS 481.219. | | | FAC 61G1-16.004 | | | THIS IS REQUIRED ON ALL SHEETS WHEATHER | | | OR NOT COMMENT IS MADE FROM OTHER REVIEW | | | -ERS. | | | | | | 4)NOTE: PLEASE SEE 2002 NEC FOR ARC | | | FAULT PROTECTION FOR NEW CIRCUITING TO | | | BEDRMS. 210.12 | | | | | | PLEASE SEE COMMENT S FROM OTHER REVIEWER | | | -S WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2004-06-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-11 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-11 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2004-06-11 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3) ALL EXITS SHALL REMAIN CLEAR AND | | | ACCESSIBLE. | | | | | | 4) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR FIRE SPRINKLER REMODEL IF IT EXCEEDS | | | FIVE OR MORE SPRINKLER HEADS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-28 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-28 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2004-06-28 00:00:00 | TO COMM BD#22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-06-22 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-06-11 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2004-06-11 00:00:00 | TO COMM BD#27 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-06 |
Time |
15:36 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-07-06 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | PROVISO: | | | PLANS DO NOT INDICATE RETURN AIR.PER | | | 2001 FBC(M) 601.4, ROOMS THAT ARE | | | SEPARATED BY DOORS FROM THE RETURN AIR, | | | SHALL HAVE A RETURN AIR JUMPER, TRANSFER | | | OR DUCTED RETURN FROM THAT SPACE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-18 |
Time |
10:49 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-06-18 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | DENIED: | | | CERTIFICATE OF AUTHORIZATION # REQUIRED | | | PLANS ARE OTHERWISE CODE COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
|