Plan Review Details - Permit 04060478
Plan Review Stops For Permit 04060478
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 11:06 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 11:06 Sent To M
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-06-14 Cont ID  
Sent By csiegber Date 2004-06-11 Time 11:06 Rev Time 0.30
Received By pkrauss Date 2004-06-14 Time 14:33 Sent To  
Notes
2004-06-14 00:00:00PROVISO:
 PLAN INDICATES EMERGENCY DRAIN LOCATED
 OUTSIDE TO THE OPEN PORCH.PER 2001
 FBC(M) 307.2.3, EMERGENCY DRAIN SHALL
 TERMINATE AT A CONSPICUOUS POINT TO
 SERVE AS AN ALARM THAT THE PRIMARY DRAIN
 IS RESTRICTED OR HAVE A FLOAT SWITCH.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.