| Plan Review Stops For Permit 04060338 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2005-04-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-04-06 |
Time |
14:16 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-04-06 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2005-04-06 00:00:00 | REVISION DATED 3/8/05 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2005-03-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-03-18 |
Time |
16:53 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2005-03-18 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2005-03-18 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)DETAILS 12 THROUGH 15, SHEET A4.2 | | | REFER TO "ADDITION".THE FREEZER WAS | | | SHOWN AS EXISTING ON THE PERMIT SET OF | | | PLANS.IF THIS IS AN ADDITION, PROVIDE | | | AREA CALCULATIONS.IMPACT FEES | | | (233-5025) AND ZONING REVIEWS REQUIRED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-11-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-24 |
Time |
13:55 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-11-24 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-11-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-11-03 |
Time |
16:48 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-11-03 |
Time |
16:20 |
Sent To |
PC |
|
| Notes |
| 2004-11-03 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SEE PREVIOUS LISTS; BEFORE | | | RESUBMITTING PLEASE SIGN THE OWNER/AGENT | | | LINE OF THE ENERGY CALC.THIS CAN BE | | | DONE BY AN OWNER OR AGENT FOR THE OWNER; | | | NOT REQUIRED TO BE DONE BY THE | | | ARCHITECT. | | | | | | 2.)SEE PREVIOUS LISTS; FLORIDA STATE | | | OR LOCAL PRODUCT APPROVAL REQUIRED IN | | | ADDITION TO THE NOAS SUBMITTED. | | | WWW.FLORIDABUILDING.ORG.FAC9B-72. | | | | | | 3.)PLEASE PROVIDE DESIGN LOAD | | | INFORMATION FOR THE TRUSS STORAGE.THE | | | LETTER STATES THAT "ANALYSIS" HAS BEEN | | | DONE.PLEASE PROVIDE THE INFORMATION - | | | ADDITIONAL LOAD, DESIGN LOAD OF EXISTING | | | TRUSSES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-31 |
Time |
10:11 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-08-31 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2004-08-31 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC BEFORE ISSUANCE. | | | | | | 2.)DOOR #2 LACKS THE MANEUVERING | | | CLEARANCE REQUIRED BY FBC11 FIGURE 25 | | | (MIN 12", PLAN SHOWS 7 1/2").REVISE | | | AFFECTED SHEETS. | | | | | | 3.)PROVIDE LOADING INFORMATION FOR | | | THE SHUTTER STORAGE, A4.2.SHOW THAT | | | THE EXISTING TRUSSES CAN ACCOMODATE THIS | | | ADDITIONAL LOAD. | | | | | | 4.)THERE IS A STRUCTURAL MULLION FOR | | | THE STOREFRONT SYSTEM THAT DOES NOT | | | APPEAR TO BE INCLUDED IN THE NOA | | | (ANGLED APPLICATION).ADDRESS. | | | | | | 5.)SOME SHEETS ARE NOT SIGNED, SEALED | | | AND DATED (EC1, EC2, EC3, A2.3, A3, A6.2 | | | A7, A7.1, A8, A9, A9.1, M0, M3, M4, M5, | | | P0, E0, E1, E4, E6), ONE SET. | | | | | | 6.)FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL REQUIRED IN ADDITION TO THE | | | TEST REPORT.WWW.FLORIDABUILDING.ORG | | | THIS IS REQUIRED FOR ALL OF THE DADE | | | COUNTY NOAS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-13 |
Time |
16:31 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2004-07-13 |
Time |
16:31 |
Sent To |
PC |
|
| Notes |
| 2004-07-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SIGN THE OWNER/AGENT LINE OF THE | | | ENERGY CALC (P2) .PROVIDE THE PRINTED | | | NAME AND LICENSE NUMBER OF THE PERSON | | | WHO PREPARED THE ENERGY CALC. | | | | | | 2.)FLORIDA STATE, LOCAL OR SITE | | | SPECIFIC PRODUCT APPROVALS REQUIRED | | | IN ADDITION TO THE NOAS.PLEASE SEE | | | WWW.FLORIDABUILDING.ORG (PRODUCT | | | APPROVAL) FOR MORE INFORMATION. | | | | | | 3.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED.FS713.13 | | | | | | 4.)THE DOUBLE DOORS 1A AND 1B ARE | | | REQUIRED TO COMPLY WITH FBC11-4.13.7 | | | (MINIMUM OF 48" PLUS THE WIDTH OF THE | | | DOOR), FIGURE 26(A). | | | | | | 5.)REGARDING DOORS #7 AND #2 (SERVICE& | | | COMMUNITY ROOM) DOUBLE LEAF DOORS ARE | | | TO COMPLY WITH 11-4.13.4 AND 11-4.13.5. | | | | | | 6.)THE DOOR TO THE WOMEN'S | | | ACCESSIBLE STALL IS TO HAVE THE | | | MANUEVERING CLEARANCE AS REQUIRED BY | | | FBC11-4.13.6, FBC11-4.23.2, FIGURE 25. | | | | | | 7.)PROVIDE INFORMATION AS TO WHERE | | | AND HOW THE HURRICANE SHUTTERS WILL BE | | | STORED.IF THEY ARE STORED VERTICALLY, | | | PROVIDE A STRUCTURAL RACK DETAIL. | | | | | | 8.)THE PRODUCT APPROVAL FOR DOOR #6, | | | THE STEEL ENTRY DOOR, HAS A PRODUCT | | | LIMITATION 3.2, UNIT SHALL BE INSTALLED | | | ONLY AT LOCATIONS PROTECTED BY A CANOPY | | | OR OVERHANG SUCH THAT THE ANGLE BETWEEN | | | THE EDGE OF CANOPY OR OVERHANG TO SILL | | | IS LESS THAN 45 DEGREES.ADDRESS. | | | | | | 9.)PROVIDE PRODUCT APPROVALS FOR THE | | | ENTRY DOORS #1A AND #5. | | | | | | 10.) PROVIDE A HURRICANE SHUTTER | | | ATTACHMENT SCHEDULE, SEE ATTACHED FORM. | | | IF NOT PROVIDED BEFORE PERMIT ISSUANCE, | | | THE SHUTTERS WILL REQUIRE A SEPARATE | | | PERMIT. | | | | | | 11.) ANY PRODUCT APPROVALS REQUIRED BUT | | | NOT SUBMITTED PROPERLY BEFORE ISSUANCE | | | WILL REQUIRE SEPARATE PERMITS FOR THOSE | | | ITEMS. | | | | | | 12.) IT APPEARS THAT THERE IS A | | | STRUCTURAL ANGLED MULLION AT DOOR #1A. | | | PLEASE PROVIDE PRODUCT APPROVAL/TEST | | | REPORTS. | | | | | | 13.)SEPARATE PERMITS REQUIRED FOR THE | | | SIGNS. | | | | | | 14.)PROVIDE SIGNAGE TO COMPLY WITH | | | FBC704.2.1.4; NOTE ON PLAN. | | | | | | 15.)PROVIDE A LOCATION FOR THE | | | STORAGE OF THE HURRICANE SHUTTERS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2005-04-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-04-05 |
Time |
14:34 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-04-05 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2005-04-05 00:00:00 | REDLINED 2002 NEC 210.8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2005-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-14 |
Time |
17:27 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2005-03-14 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2005-03-14 00:00:00 | ******* UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002, | | | PLEASE INCLUDE ALL INFORMATION ON TITLE | | | BLOCK AS REQUIRED. | | | PLEASE SEE THIS WAS NOTED ON ALL | | | PREVIOUS REVIEWS ON LAST THREE | | | ELECTRICAL REVIEWS. | | | THIS IS REQUIRED FOR ALL TRADES AND FOR | | | ALL SHEETS WHEATHER OR NOT COMMENT IS | | | MADE BY OTHER REVIEWER(S). | | | | | | 2)NOTE: PLEASE INCLUDE NOTE FOR REQUIRED | | | GFI PROTECTION. PLEASE SEE SECTION | | | 210.8(B)(3) IS NEW FOR THE 2002 CODE AND | | | REQUIRES ALL 15- AND 20-AMPERE, 125-VOLT | | | RECEPTACLES IN NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 3)NOTE: PLEASE SEE TITLE AREA ON PLANS | | | FOR REVISIONS. PLEASE SEE NEW REVISION | | | IS INDICATED AS # 7 AND PREVIOUS | | | REVISION WAS REV #1? PLEASE VERIFY | | | REVISIONS #2-#6?? PLEASE SHOW AND | | | INDICATE ANY OTHER REV'S. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-08 |
Time |
15:55 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-10-08 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2004-10-08 00:00:00 | PE'S PRINTED LICENSE # AS REQUIRED UNDER | | | FAC 61G15-23.002 NOT PRINTED ON TITLE | | | BLOCK. HAND WROTE ON E-SHEETS ONLY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-31 |
Time |
13:44 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-08-31 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2004-08-31 00:00:00 | *************** UNSAT *************** | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | STILL NEED TO BE ADDRESSED.. | | | | | | 1)NOTE: PLEASE SEE BOTH SETS OF PLANS | | | ARE REQUIRED TO BE SIGNED, DATED AND | | | SEALED. FS 471.025 FAC 61G15-23.002 | | | | | | 2)NOTE: PLEASE SEE ABOVE FAC FOR MISSING | | | INFORMATION REQUIRED ON TITLE BLOCKS. | | | | | | THE ABOVE TWO ARE FOR ALL TRADES | | | WHEATHER OR NOT COMMENT IS MADE BY THOSE | | | REVIEWERS. | | | | | | 3)NOTE: PLEASE SEE NOTE #4 FROM PREVIOUS | | | REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-15 |
Time |
13:06 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2004-06-15 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: PLEASE INCLUDE ALL INFORMATION | | | ON TITLE BLOCKS AS REQUIRED UNDER | | | FAC 61G15-23.002/ 61G1-16.004 | | | PLEASE INCLUDE ALL NAMES AND LICENSE #'S | | | | | | PLEASE ALOS SEE ONLY ONE SET OF PLANS | | | ARE SIGNED, DATED AND SEALED AS REQUIRED | | | UNDER FS 471.025/ 61G15-23.002 | | | | | | 2)NOTE: PLEASE VERIFY REQUIRED SIGN | | | CIRCUIT PER 600.5 | | | | | | 3)NOTE: PLEASE SEE PANEL "P1", SHOWS | | | A PANEL "ILG", YET RISER SHOWS "IGP". | | | (MISPRINT) | | | | | | 4)NOTE: PLEASE PROVIDE COMPLETE LOAD | | | CALCULATION ON EXISTING SERVICE AND | | | SEC'S. SOME OF THE SERVICES ON THIS | | | MALL ARE IN DANGER OF HEATED CONDUCTORS | | | AND OVERLOADED SERVICES AND SOME | | | SEEM TO BE "MAXED" OUT AND CLOSE TO | | | BEING OVERLOADED AT PRESENT TIME. | | | 215.5/220 | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | AS SOME MAY HAVE AN AFFECT ON ELECTRICAL | | | PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW SHEETS INTO TWO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2005-04-12 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-04-12 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-04-12 |
Time |
09:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2005-03-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-03-23 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-03-23 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-10-20 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-10-20 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-10-20 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2004-09-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-09-16 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-09-16 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-06-10 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-06-10 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) ALL COOLERS AND FREEZERS ARE TO | | | BE FIRE SPRINKLER PROTECTED AS NOTED | | | ON THE PLANS. | | | | | | 3) PLEASE INDICATE ALL INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 4) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY NEW HOOD, DUCTS, OR SUPPRESSION | | | SYSTEMS. | | | | | | 5) A MINIMUM OF AT LEAST 10 FEET | | | CLEARANCE IS REQUIRED BETWEEN EXHAUST | | | AND SUPPLY EQUIPMENT. | | | | | | 6) PLEASE INDICATE OCCUPANT LOAD FOR | | | THE LOCATION INCLUDING EMPLOYEES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-30 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-30 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2005-03-30 00:00:00 | TO "COMM" BD#23 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2005-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-10 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-10 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2005-03-10 00:00:00 | TO "COMM" BD#18 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-03-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-02 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-02 |
Time |
13:08 |
Sent To |
M |
|
| Notes |
| 2005-03-02 00:00:00 | TO "M" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-11-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-11-09 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-11-09 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2004-11-09 00:00:00 | TO COMM BD#37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-10-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-05 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-05 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2004-10-05 00:00:00 | TO COMM BD#39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-19 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-19 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2004-08-19 00:00:00 | TO COMM BD#40 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-07-14 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2004-06-08 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2004-06-08 00:00:00 | TO COMM BD#63 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2005-04-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-04-26 |
Time |
17:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
|
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-03-08 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-03-08 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-10-15 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-15 |
Time |
08:41 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-10-15 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-30 |
Time |
09:30 |
Rev Time |
0.55 |
| Received By |
pkrauss |
Date |
2004-08-30 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2004-08-30 00:00:00 | DENIED: | | | PLAN SHEETS M0, M3, M4,AND M5 IN ONE | | | SET OF PLANS ARE NOT SIGNED, SEALED, OR | | | DATED IN ACCORDANCE WITH FS 471.025 & | | | FAC 61G15-23.002.PLEASE ALSO PROVIDE | | | ALL LICENSE NUMBERS OF ENGINEERS. | | | | | | PROVISO: | | | ADDITIONAL PERMITS REQUIRED FOR THE | | | WALK-IN COOLER & HOOD.PLANS SUBMITTED | | | WITH THE BUILDING PERMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-21 |
Time |
07:43 |
Rev Time |
1.55 |
| Received By |
pkrauss |
Date |
2004-06-21 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2004-06-21 00:00:00 | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | FOR REVIEW: | | | | | | 1.PROVIDE MANUFACTURER SUBMITTAL AND | | | INSTALLLATION INSTRUCTIONS FOR THE | | | OVENS, AND WALK-IN COOLERS. | | | | | | PLEASE NOTE, ADDITIONAL PERMITS | | | REQUIRED FOR THE HOOD, WALK-IN COOLERS | | | AND FIRE SUPPRESSION. | | | | | | 2.PLEASE CLARIFY HOOD, TYPE I OR TYPE | | | II. | | | | | | 3.INDICATE CLEARANCE TO COMBUSTIBLES. | | | | | | 4.PLANS SHALL COMPLY WITH FS 471.025 | | | & FAC 61G15-23.002, PROVIDE NAMES AND | | | LICENSE #'S.PLANS ARE TO BE SIGNED, | | | SEALED, AND DATED. | | | | | | 5.PLAN SHEET A2.2 #11 INDICATES NEW | | | GAS FIRE PLACE FLUE.PLEASE CLARIFY | | | HEIGHT REQUIREMENT.PLEASE NOTE | | | PROXIMITY TO PARAPET WALL.TERMINATION | | | SHALL COMPLY WITH 2001 FBC(F) 506.6.2. | | | | | | 6.PLAN SHEET M2 HVAC PLAN NOTE #9, SEE | | | 3/M4.PLAN SHEET M4 DOES NOT INDICATE | | | DETAIL 3. | | | | | | 7.PROVIDE DETAILS FOR SECURING FLUES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-11-30 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-30 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2005-04-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-04-23 |
Time |
17:15 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2005-04-23 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2005-04-23 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | | | | 1) SHTS A6 & A6.1 - CHANGES TO THE | | | EQUIPMENT SHOWN ON SHT A6, SHALL BE | | | REFLECTED ON THE EQUIPMENT SCHEDULE SHT | | | A6.1. SECTION 104.2.1. | | | 2) SHT P-1 LATEST REVISION SHOWN IS | | | REVISION #5. THERE ARE OTHER CHANGES | | | WITH NO REVISION NUMBER SHOWN. PLEASE | | | SHOW ALL REVISIONS WITH CLOUDS AND | | | REVISION NUMBERS. SECTION 104.2.1. | | | 3) SHT P-2 REVISION #7 WAS NOT FOUND. | | | NUMEROUS UN-NUMBERED REVISIONS ON THE | | | SHEET. SHOW REVISION NUMBER ON ALL | | | CHANGES. SECTION 104.2.1. | | | 4) SHT P-3 NO REVISION #5 FOUND. SOME | | | CLOUDS WITH OUT NUMBERS. - RED LINE | | | CHANGES TO GAS RISER & GAS NOTES ON THE | | | PERMITTED SET OF PLANS WERE NOT SHOWN ON | | | THE REVISION. THESE RED LINE CHANGES | | | SHALL BE INCORPORATED INTO THE LATEST | | | REVISION TO MAKE THE INFORMATION REFLECT | | | WHAT WAS APPROVED. MAKE CHANGES PRIOR TO | | | RESUBMITTING REVISIONS. SECTIONS 401.8 | | | THRU 402.5.2 AND TABLES 402(1) THRU | | | 402(34). | | | 5) SHTS P-4 & P-5 NO REVISIONS WERE | | | NOTED ON THESE SHEETS. DO NOT SUBMIT | | | SHEETS WITHOUT REVISIONS AS A REVISION. | | | SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2005-03-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-03-22 |
Time |
11:29 |
Rev Time |
1.36 |
| Received By |
kstevens |
Date |
2005-03-22 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2005-03-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ENGINEER SHALL LEGIBLY THEIR NAME, | | | ADDRESS, AND LICENSE NUMBER ON EACH | | | SHEET. FAC 61G15-23.002 & FS 471.025 | | | 2) SHT P3 INDICATES A REVISION WITH THE | | | NUMBER 5 THAT WAS NOT ON THE PREVIOUS | | | SHEET P3. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-11-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-11-23 |
Time |
16:01 |
Rev Time |
1.75 |
| Received By |
kstevens |
Date |
2004-11-22 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2004-11-23 00:00:00 | SEPARATE GAS PERMIT REQUIRED. - PER | | | CONVERSATION WITH ENGINEER 11-23-4 ALL | | | PIPE WILL BE SCREW PIPE. NO WELD PIPE IN | | | SYSTEM. - PER MANUF. SPECIFICATION SHEET | | | THE ROOF TOP UNIT IS 129,600 BTU NOT | | | 100,000 BTU AS SHOWN. - TOLD ENGINEER | | | AND ADVISED THAT NO PIPE SIZE CHANGES | | | WERE REQUIRED AND THAT I WILL INDICATE | | | THE CHANGE ON PLANS. HE AGREED. KSTEVENS | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2004-10-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-22 |
Time |
17:55 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2004-10-21 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2004-10-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | FBC-2001 PLUMBING | | | | | | 1) STAMPED SHEETS FROM DBPR RESTURANT & | | | HOTEL DIVISION ARE REQUIRED IN EACH SET | | | OF PLANS WITH THE WORKSHEETS FROM DBPR | | | INCLUDED. SECTION 101.4.7 | | | 2) APPROVAL SHEET FROM RODNEY COMPO FOR | | | THE GREASE INTECEPTOR REQUIRED. WASTE | | | ORD. 2938-96 | | | 3) WATER HAMMER ARRESTORS REQUIRED BY | | | SECTION 604.9 SHALL BE SHOWN ON THE | | | WATER RISER DIAGRAM. (AT ICE MAKER, AND | | | DISH WASHER). W.H.A.'S SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE RANGE | | | NOT IN THE CEILING. PDI-WH 201. | | | 4) GAS REQUIREMENTS: - THE DOUBLE RACK | | | OVEN DOES NOT SHOW A GAS LISTING. UL | | | LISTING DOES NOT ADDRESS GAS CONCERNS. - | | | FIRE PLACE MANUF. SHEET SHOWS 17,OOO BTU | | | MAXIMUM INPUT, BUT GAS RISER SHOWS | | | 30,000 BTU. PLEASE CLARIFY. - MANUF. | | | SHEET FOR THE SF-1 UNIT ON THE ROOM & | | | THE WATER HEATER ARE NOT SUBMITTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-09-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-17 |
Time |
09:02 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2004-09-17 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2004-09-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESS- | | | ED, OR NOT ADDRESSED PROPERLY. THE SAME | | | COMMENT NUMBER WILL BE USED FROM THE | | | FIRST REVIEW TO AVOID CONFUSION. | | | 6) BOTY SETS OF PLANS SHALL BE SIGNED - | | | SEALED & DATED BY THE ARCHITECT OR ENG- | | | INEER AS REQUIRED BY FAC 61G1-16.003 OR | | | 61G15-23.002 & FS 481.2055 OR FS 471.025 | | | SOME SHEETS HAVE NOT BEEN SIGNED/SEALED/ | | | DATED. | | | 8) SHT P0 SEC 15000 PLUMBING (3)(D) AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | NOTES. PDI-WH 201. THIS NOTE HAS NOT | | | BEEN DELETED. | | | 10) NO REPLY FROM RODNEY COMPO CONCERN- | | | ING GREASE INTECEPTOR RECIEVED. WASTE | | | ORD. 2938-96 (561) 837-4074. | | | 12) INFORMATION REQUIRED FOR GAS PERMIT | | | B) SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED. | | | 14) SHT P3 WATER ISOMETRIC, WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIX- | | | TURES IN AN "EFFECTIVE RANGE" NOT IN THE | | | CEILING AS SHOWN. PDI-WH 201 & MANUF. | | | INSTALLATION INSTRUCTIONS. - STILL SHOWN | | | IN CEILING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-06 |
Time |
16:36 |
Rev Time |
7.00 |
| Received By |
kstevens |
Date |
2004-07-06 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) PLANS HAVE BEEN ROUTED TO THE DBPR | | | HOTEL AND RESTURANT DIVISION. THE TWO | | | PAGE WORKSHEETS RETURNED FROM DBPR SHALL | | | BE ATTACHED TO EACH SET OF PLANS FOR RE- | | | VIEW. SECTIONS 101.4.7 & 104.2.1. | | | 2) SUBMIT CALCULATIONS FOR MINIMUM FAC- | | | ILITIES PER TABLES 1003.1 & 403.1. INDI- | | | CATE IF SEATING IS FIXED OR NOT FIXED. | | | 3) SHT D1, ALL CAPPED AND/OR ABANDONED | | | PLUMBING PIPING SHALL BE INSPECTED PRIOR | | | TO COVERING. NO DEAD ENDS ALLOWED PER | | | SECTION 704.5 | | | 4) SHT A2.2 KEYED NOTES: #11 STATES FLUE | | | TO BE A MINIMUM OF 2' FROM VERTICAL WALL | | | BUT FUEL GAS SECTION 506.6.2 REQUIRES A | | | MINIMUM OF 8' FROM VERTICAL WALLS. NOTE | | | #11 ALSO STATES 1' ABOVE ROOF, BUT CODE | | | SECTION 506.6.2 STATES THE VENT SHALL | | | TERMINATE NOT LESS THAN 2 FEET HIGHER | | | THAN ANY PORTION OF A BUILDING WITHIN 10 | | | FEET. SEE DETAIL 17 ON SHT A7.1 | | | 5) SUBMIT MANUF. SPECIFICATION/INSTALL- | | | ATION SHEETS FOR THE FIREPLACE AND THE | | | VENTING SYSTEM. | | | 6) BOTH SETS OF PLANS SHALL BE SIGNED - | | | SEALED & DATED BY THE ARCHITECT/ENGINEER | | | OF RECORD. FAC 61G1-16.003/61G15-23.002 | | | FS 481.2055/471.025. | | | 7) SHT P0 DETAIL #2 FILTERS SHALL BE | | | "NSF" COMPLIANT. SUBMIT MANUF. SPECIFIC- | | | ATION SHEETS. | | | 8) SHT P0 SEC 15000 PLUMBING (3)(D) AIR | | | CHAMBERS ARE NOT APPROVED. DELETE FROM | | | NOTES. PDI-WH 201. | | | 9) P0 GENERAL NOTES #4 ADOPTED CODE IS | | | FLA. BUILDING CODE - 2001 PLUMBING, NOT | | | SBCCI-94 STANDARD PLUMBING CODE AS INDI- | | | CATED. UPDATE GENERAL NOTES. SEC 104.2.1 | | | 10) GREASE INTERCEPTOR SHALL BE SIZED BY | | | RODNEY COMPO ENVIRONMENTAL COMPLIANCE. | | | PLEASE CONTACT HIM AT (561) 837-4074. | | | WASTE ORD. #2938-96. | | | 11) RPZ BACKFLOW REQUIRED ON THE WATER | | | SERVICE. SECTION 608.13.2 | | | 12) FOLLOWING INFORMATION REQUIRED FOR | | | GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2001 | | | FUEL GAS CODE. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | C. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2001 FUEL | | | GAS CODE SECTION 304. | | | D. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2001 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | - SHT P2 PLAN NOTES #9 INDICATES 7" TO | | | 12" WATER COLUMN - CHARTS IN FBC-2001 | | | FUEL GAS ARE FOR 12" TO 14" WATER COLUMN | | | WHICH IS 1/2 LB. PRESSURE. PLEASE VERIFY | | | DELIVERY PRESSURE WITH FUEL PROVIDER. | | | E. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2001 FUEL GAS CODE SEC 402.2 | | | 13) DISHWASHER (27A) SHALL DRAIN INTO | | | THE SANITARY SYSTEM, NOT THE GREASE SYS- | | | TEM. PER UTILITY DEPT. | | | 14) SHT P3 WATER ISOMETRIC, AIR CHAMB- | | | ERS ARE NOT APPROVED. WATER HAMMER ARR- | | | ESTORS REQUIRED BY SECTION 604.9 SHALL | | | BE INSTALLED NEAR THE FIXTURES IN AN | | | "EFFICTIVE RANGE" NOT IN THE CEILING. | | | PDI-WH 201 & MANUF. INSTALLATION INSTR. | | | 15) SHT P3 WATER ISOMETRIC, A SHUT OFF | | | VALVE IS REQUIRED ON SUPPLY LINE TO HOSE | | | BIBB. SECTION 606.2(2). | | | 15) SHTS P1 & P5. ITEMS NOT FOUND ON SHT | | | P1 BUT SHOWN ON KITCHEN EQUIPMENT SCHED- | | | ULE. ITEMS 13, 21C, 23, 23B, 54, 58, AND | | | 61. - ALSO CLAIRFY ITEM 72A SHOWN ON | | | SCHEDULE AS DECK OVEN, BUT ON FLOOR PLAN | | | IT IS IN THE FREEZER. PLEASE CORRELATE | | | PLANS TO SCHEDULE. | | | 16) SHT P1, PLAN NOTES #6 INDICATES THAT | | | FLOOR DRAINS ARE BEING USED FOR INDIRECT | | | WASTE. THIS IS NOT APPROVED. FLOOR SINKS | | | OR HUB DRAINS ARE REQUIRED FOR INDIRECT | | | WASTE. FLOOR DRAINS ARE NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. SECTIONS 802.3 | | | AND 802.3.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|