Plan Review Details - Permit 04060241
Plan Review Stops For Permit 04060241
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-06-29 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:22 Rev Time 2.00
Received By lsmith Date 2004-06-29 Time 11:17 Sent To  
Notes
2004-06-29 00:00:00BUILDING PLAN REVIEW: PASSED WITH
 PROVISO:
  
 1. PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2. IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2005-07-05 Cont ID  
Sent By btrobaug Date 2005-07-05 Time 12:00 Rev Time 0.50
Received By btrobaug Date 2005-07-05 Time 07:10 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2005-06-21 Cont ID  
Sent By btrobaug Date 2005-06-21 Time 07:48 Rev Time 1.00
Received By btrobaug Date 2005-06-20 Time 11:06 Sent To PC
Notes
2005-06-20 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE GENERATOR OUTPUT RATING FOR
 NATURAL GAS IS 125 AMPS IN THE
 SPECIFICATIONS. THE CALCULATIION FOR THE
 LOAD SERVED IS 170.4 AMPS. THE SYSTEM
 SHALL HAVE ADEQUATE CAPACITY AND RATING
 FOR THE SUPPLY OF ALL EQUIPMENT SERVED
 PER 702.5.
  
 2} THE GROUNDING ELECTRODE CONDUTOR MUST
 BE CONTINUOUS PER 250.64(C), AND SIZED
 PER 250.66. THIS COMMENT WAS REDLINED ON
 THE ORIGINAL PLAN. THE #2 GEC TO THE
 COLD WATER BOND, AND THEN A SEPARATE #4
 TO THE SUPPLEMENTARY ELECTRODE AND
 FOOTER STEEL IS IN VIOLATION. THE #2
 CONTINUOUS GEC IS REQUIRED FOR THE
 SERVICE SIZE.
 PLEASE CORRECT.
  
 3} PLEASE SHOW THE LOCATION OF ALL
 SERVICE EQUIPMENT AND GENERATOR
 EQUIPMENT ON THE PLAN. ATS, DISCONNECT,
 ETC.
  
 4} PLEASE FIELD VERIFY THE LOCATION OF
 THE RECEPTACLE IN THE NORTH EAST WALL OF
 BEDROOM #2 AS IT DOES NOT MEET THE
 SPACING REQUIREMENTS OF ARTICLE
 210.52(A)(1). THIS WAS REDLINED ON THE
 REVIEWED PLANS AS WELL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2004-06-15 Cont ID  
Sent By btrobaug Date 2004-06-15 Time 11:09 Rev Time 0.50
Received By btrobaug Date 2004-06-11 Time 15:01 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2005-07-01 Cont ID  
Sent By adarroug Date 2005-07-01 Time 17:53 Rev Time 0.00
Received By adarroug Date 2005-07-01 Time 17:53 Sent To E
Notes
2005-07-01 00:00:00TO "BTROBAUG" DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2005-06-01 Cont ID  
Sent By adarroug Date 2005-06-01 Time 09:05 Rev Time 0.00
Received By adarroug Date 2005-06-01 Time 09:05 Sent To G
Notes
2005-06-01 00:00:00TO "G" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-12-01 Cont ID  
Sent By mjacobs Date 2004-12-01 Time 18:31 Rev Time 0.00
Received By mjacobs Date 2004-12-01 Time 18:31 Sent To P
Notes
2004-12-01 00:00:00SENT TO "P" BOX/REV.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-07-01 Cont ID  
Sent By csiegber Date 2004-07-01 Time 14:22 Rev Time 0.00
Received By csiegber Date 2004-07-01 Time 14:22 Sent To B
Notes
2004-07-01 00:00:00TO LS DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-29 Cont ID  
Sent By mmclean Date 2004-06-08 Time 16:48 Rev Time 0.00
Received By lsmith Date 2004-06-08 Time 11:06 Sent To  
Notes
2004-06-09 00:00:00TO SFD RACK/E
2004-06-08 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-01-21 Cont ID  
Sent By pkrauss Date 2005-01-21 Time 12:58 Rev Time 0.30
Received By pkrauss Date 2005-01-21 Time 12:25 Sent To  
Notes
2005-01-21 00:00:00RESTAMP - NO REVISIONS
 PLEASE NOTE; BOTH MECHANICAL PLANS WERE
 FILED WITH OUR COPIES THEREFOR
 CONTRACTOR WAS MISSING THEIR COPY OF
 THE
 MECHANICAL PLAN.GAVE SHELDON FRIEFELD
 RE-STAMPED COPY & 1 OF THE ORIGINALS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-06-23 Cont ID  
Sent By btrobaug Date 2004-06-15 Time 11:09 Rev Time 0.35
Received By pkrauss Date 2004-06-23 Time 10:19 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-12-16 Cont ID  
Sent By kstevens Date 2004-12-16 Time 11:20 Rev Time 0.75
Received By kstevens Date 2004-12-16 Time 11:20 Sent To  
Notes
2004-12-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLYMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
  
 1) SANITARY RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN. THE LAUNDRY SINK
 IS NOT SHOWN ON THE RISER. SECTION
 104.2.1.
 2) IDENTIFY ALL FIXTURES AND MAKE SURE
 THE INFORMATION IS CLEAR AND READABLE.
 SECTION 104.2.1
 3) A TITLE BLOCK MUST APPEAR ON ALL
 ARCHITECTURAL DRAWINGS. FAC 61G1-16.004
 AND FS 481,025. SEE ITEMS 1 THRU 6.
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-06-28 Cont ID  
Sent By pkrauss Date 2004-06-23 Time 10:32 Rev Time 0.33
Received By jleech Date 2004-06-28 Time 17:33 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2004-06-08 Cont ID  
Sent By mmclean Date 2004-06-08 Time 16:47 Rev Time 0.00
Received By mmclean Date 2004-06-08 Time 16:47 Sent To I
Notes
***NONE***