| Plan Review Stops For Permit 04060241 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-01 |
Time |
14:22 |
Rev Time |
2.00 |
| Received By |
lsmith |
Date |
2004-06-29 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2004-06-29 00:00:00 | BUILDING PLAN REVIEW: PASSED WITH | | | PROVISO: | | | | | | 1. PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2. IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-07-05 |
Time |
12:00 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-07-05 |
Time |
07:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-06-21 |
Time |
07:48 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2005-06-20 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
| 2005-06-20 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE GENERATOR OUTPUT RATING FOR | | | NATURAL GAS IS 125 AMPS IN THE | | | SPECIFICATIONS. THE CALCULATIION FOR THE | | | LOAD SERVED IS 170.4 AMPS. THE SYSTEM | | | SHALL HAVE ADEQUATE CAPACITY AND RATING | | | FOR THE SUPPLY OF ALL EQUIPMENT SERVED | | | PER 702.5. | | | | | | 2} THE GROUNDING ELECTRODE CONDUTOR MUST | | | BE CONTINUOUS PER 250.64(C), AND SIZED | | | PER 250.66. THIS COMMENT WAS REDLINED ON | | | THE ORIGINAL PLAN. THE #2 GEC TO THE | | | COLD WATER BOND, AND THEN A SEPARATE #4 | | | TO THE SUPPLEMENTARY ELECTRODE AND | | | FOOTER STEEL IS IN VIOLATION. THE #2 | | | CONTINUOUS GEC IS REQUIRED FOR THE | | | SERVICE SIZE. | | | PLEASE CORRECT. | | | | | | 3} PLEASE SHOW THE LOCATION OF ALL | | | SERVICE EQUIPMENT AND GENERATOR | | | EQUIPMENT ON THE PLAN. ATS, DISCONNECT, | | | ETC. | | | | | | 4} PLEASE FIELD VERIFY THE LOCATION OF | | | THE RECEPTACLE IN THE NORTH EAST WALL OF | | | BEDROOM #2 AS IT DOES NOT MEET THE | | | SPACING REQUIREMENTS OF ARTICLE | | | 210.52(A)(1). THIS WAS REDLINED ON THE | | | REVIEWED PLANS AS WELL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-15 |
Time |
11:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-06-11 |
Time |
15:01 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-07-01 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-07-01 |
Time |
17:53 |
Sent To |
E |
|
| Notes |
| 2005-07-01 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2005-06-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-01 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-01 |
Time |
09:05 |
Sent To |
G |
|
| Notes |
| 2005-06-01 00:00:00 | TO "G" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-01 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-01 |
Time |
18:31 |
Sent To |
P |
|
| Notes |
| 2004-12-01 00:00:00 | SENT TO "P" BOX/REV. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-01 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-01 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
| 2004-07-01 00:00:00 | TO LS DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2004-06-08 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2004-06-09 00:00:00 | TO SFD RACK/E | | 2004-06-08 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-01-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-01-21 |
Time |
12:58 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2005-01-21 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2005-01-21 00:00:00 | RESTAMP - NO REVISIONS | | | PLEASE NOTE; BOTH MECHANICAL PLANS WERE | | | FILED WITH OUR COPIES THEREFOR | | | CONTRACTOR WAS MISSING THEIR COPY OF | | | THE | | | MECHANICAL PLAN.GAVE SHELDON FRIEFELD | | | RE-STAMPED COPY & 1 OF THE ORIGINALS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-06-15 |
Time |
11:09 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-06-23 |
Time |
10:19 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-16 |
Time |
11:20 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-12-16 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2004-12-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLYMBING | | | FBC-2001 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. THE LAUNDRY SINK | | | IS NOT SHOWN ON THE RISER. SECTION | | | 104.2.1. | | | 2) IDENTIFY ALL FIXTURES AND MAKE SURE | | | THE INFORMATION IS CLEAR AND READABLE. | | | SECTION 104.2.1 | | | 3) A TITLE BLOCK MUST APPEAR ON ALL | | | ARCHITECTURAL DRAWINGS. FAC 61G1-16.004 | | | AND FS 481,025. SEE ITEMS 1 THRU 6. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-23 |
Time |
10:32 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2004-06-28 |
Time |
17:33 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-08 |
Time |
16:47 |
Sent To |
I |
|
| Notes |
|
|