| Plan Review Stops For Permit 04051124 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2005-05-10 00:00:00 | SUMITTAL FOR ENGINEERED ALTERNATE | | | FASTENING OF MARVIN WINDOWS WITH 1X | | | BUCKS IS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-10-26 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-10-26 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-08-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-08-20 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2004-08-20 00:00:00 | DENIED | | | | | | 1) INCOMPLETE TITLE BLOCK INFORMATION. | | | FAC 61G-16.004 REQUIRES THE ARCHITECT'S | | | FIRM LICENSE NUMBER AND THE PRINTED | | | NAME OF THE PERSON SEALING THE DOCUMENT | | | IS REQUIRED ON EVERY SHEET. SEE FS 481. | | | | | | FAC 61G15-23.002 IF PRACTICING THROUGH A | | | DULY AUTHORIZED ENGINEERING BUSINESS, | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME AND LICENSE NUMBER, AS WELL AS, THE | | | NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. SEE FS 471. | | | | | | 2) SHEETS A4.03, A5.03, A7.02, A7.11 AND | | | A9.03 ARE MISSING FROM THE NEW PLAN SET. | | | | | | 3) PROVIDE STRUCTURAL DETAILS FOR THE | | | CHIMNEY AT THE LOGGIA. SPECIFY THE | | | ATTACHMENT TO ROOF, FRAMING, EXTERIOR | | | COVERING, ETC. SHOW COMPLIANCE WITH | | | FBC 2804.2.4 WHICH REQUIRES CHIMNEY TO | | | BE 3 FEET ABOVE THE HIGHEST POINT THAT | | | IT PASSES THROUGH THE ROOF AND AT LEAST | | | 2 FEET HIGHER THAN ANY PORTION OF THE | | | ROOF OR BUILDING WITHIN 10 FEET. | | | | | | 4) SUBMIT AN ADDITIONAL COPY OF THE | | | SITE SPECIFIC PRODUCT APPROVAL. THE NOA | | | NUMBER LISTED ON THE SHEET ATTACHED TO | | | THE SITE SPECIFIC FORM FOR THE FRENCH | | | DOORS IS THE OLD NUMBER. PLEASE SPECIFY | | | THE CURRENT NOA NUMBER. | | | | | | 5) SPECIFY THE FIREBLOCKING AT THE | | | CONCEALED SPACE BETWEEN STAIR STRINGERS | | | AT THE TOP AND BOTTOM OF RUNS AS | | | REQUIRED BY FBC 2305.1.4(3). | | | | | | 6) SPECIFY THE LOCATION AND MATERIAL FOR | | | THE DRAFTSTOPPING AT THE FLOOR/CEILING | | | ASSEMBLY DIVIDING IT INTO APPROXIMATELY | | | 500 SQFT AREAS PER FBC 2305.2.2. | | | | | | 7)SUBMIT STATE OR LOCAL PRODUCT APPROVAL | | | FOR THE FOLLOWING: | | | - DOUBLE HUNG WINDOWS (IMPACT) | | | - FIXED WINDOWS (IMPACT) | | | - 8 PANEL DOOR TO LAWN STORAGE | | | - OVERHEAD GARAGE DOORS | | | COORDINATE THE PRODUCT APPROVALS THAT | | | ARE SUBMITTED WITH THE WINDOWS AND DOORS | | | THAT ARE SPECIFIED IN THE SCHEDULES ON | | | THE PLANS. THEY NEED TO CORRESPOND TO | | | EACH OTHER. | | | | | | 8) THE NEW PLANS AND PRODUCT APPROVALS | | | ARE REQUIRED TO BE REVIEWED BY THE | | | HISTORIC PRESERVATION DEPARTMENT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-16 |
Time |
11:04 |
Rev Time |
6.00 |
| Received By |
rmcdouga |
Date |
2004-06-28 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2004-06-28 00:00:00 | DENIED | | | | | | 1) SUBMIT A COPY OF THE PAID RECEIPT FOR | | | THE COUNTY IMPACT FEES. | | | | | | 2) SPECIFY THE SIZE OF THE ATTIC ACCESS | | | ON THE SECOND FLOOR. FBC 2309.6 | | | | | | 3) THE FULL BATH ON THE FIRST FLOOR IS | | | REQUIRED TO HAVE A DOOR WITH A 29" CLEAR | | | OPENING. FBC 11-4.23.2 | | | | | | 4) INCOMPLETE TITLE BLOCK INFORMATION, | | | FIRM NUMBER, PRINTED NAME OF PERSON | | | SIGNING AND SEALING, ETC. SEE FS 471 AND | | | 481. ENGINEER'S TITLE BLOCK INFO IS NOT | | | ON STRUCTURAL SHEETS. | | | | | | 5) INCOMPLETE DESIGN CRITERIA. | | | FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. NOTE: | | | INTERNAL PRESSURE COEFFICENT IS + OR - | | | 0.18 FOR ENCLOSED STRUCTURE IF DESIGNING | | | TO ASCE 7-98. SPECIFY FBC NOT SBC. | | | | | | 6) SPECIFY HOW TERMITE PROTECTION WILL | | | BE PROVIDED. FBC 1816 | | | | | | 7) THE UNVENTED ATTIC WITH ICYNENE | | | INSULATION IS ACCEPTABLE UNDER FBC 103.7 | | | ALTERNATE MATERIALS AND METHODS WITH THE | | | FOLLOWING CONDITIONS. 1) THE SYSTEM/ | | | ASSEMBLY MUST BE DESIGNED BY A FLORIDA | | | REGISTERED DESIGN PROFESSIONAL, 2) | | | INSULATION MUST BE INSTALLED CONTINOUSLY | | | IN THE UPPER PLANE OF THE ROOF ASSEMBLY | | | DECK/SHEATHING WITH SPECIFIED, APPROVED | | | INSULATION PRODUCTS, AND THE CEILING | | | SPACE IS NOT SEPARATED FROM THE | | | CONDITIONED SPACE BELOW WITH INSULATION. | | | SUBMIT SIGNED AND SEALED REPORT SPECIFY- | | | ING HOW MATERIAL IS TO BE APPLIED AND | | | MATERIAL SPECIFICATIONS. | | | | | | 8) THE BALCONY GUARDRAIL IS REQUIRED TO | | | HAVE A BOTTOM RAIL THAT WILL REJECT A | | | 2" DIAMETER SPHERE. FBC 1015.3 | | | | | | 9) SPECIFY THE CONNECTORS THAT WILL BE | | | USED TO ATTACH THE 2ND FLOOR POST | | | COLUMNS TO THE WOOD BEAMS. | | | | | | 10) SPECIFY THE ATTACHMENT OF THE 2ND | | | FLOOR GUARDRAILS TO THE WOOD COLUMNS. | | | | | | 11) INDICATE ON THE PLANS THAT THE SPACE | | | BETWEEN THE INTERMEDIATE RAILS AT THE | | | INTERIOR STAIRS WILL REJECT A 4" SPHERE. | | | SEE FBC 1015.3 | | | | | | 12) PROVIDE DETAILS, SECTIONS, ETC. | | | INDICATING THE CONSTRUCTION AND | | | CONNECTIONS OF THE TWO CHIMNEYS. SPECIFY | | | THE REQUIRED HEIGHT ABOVE THE ROOF PER | | | FBC 2804.2.4. | | | | | | 13) SPECIFY RING SHANK NAILS FOR ROOF | | | SHEATHING IN ZONE 3 FOR MEAN ROOF HEIGHT | | | OF 25'- 35' PER CITY AMENDMENTS TO FBC | | | TABLE 2306.1. | | | | | | 14) SPECIFY A BOTTOM CORD LIVE LOAD OF | | | 10 PSF FOR ATTICS WITHOUT STORAGE. SEE | | | FBC TABLE 1604.1 | | | | | | 15) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. | | | SUBMIT STATE PRODUCT APPROVAL FOR THE | | | FOLLOWING: | | | - TRUSS CONNECTORS | | | - DOUBLE HUNG WINDOWS (IMPACT) | | | - OVERHEAD GARAGE DOORS | | | - FIXED WINDOWS (IMPACT) | | | - 8-PANEL DOOR TO LAWN STORAGE | | | NOTE: PRODUCT APPROVALS MUST BE APPROVED | | | BY THE HISTORIC PRESERVATION DEPT. | | | THE STOREFRONT DOORS MAY NOT BE ACCEPT- | | | ABLE. | | | NO CASEMENT WINDOWS ARE SHOWN ON PLANS. | | | WHY WAS PRODUCT APPROVAL FOR CASEMENT | | | WINDOWS SUBMITTED. | | | | | | 16) THE UPLIFT VALUE FOR THE HETAL 20 | | | CONNECTOR IN THE ANCHOR SCHEDULE IS | | | INCORRECT. THE UPLIFT VALUE IS 1810# | | | WITHOUT THE ONE THIRD STRESS INCREASE IN | | | THE STEEL CALCULATIONS. SEE 2004 SIMPSON | | | CATALOG. | | | | | | IF YOU HAVE QUESTIONS PLEASE CALL: | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2005-07-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-07-01 |
Time |
10:45 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-07-01 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-08-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-04 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2004-08-04 |
Time |
08:52 |
Sent To |
P |
|
| Notes |
| 2004-08-04 00:00:00 | | | | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALLED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BE RATED FOR THE AVAILABLE FAULT | | | CURRENT. | | | | | | SUBMIT SAME FOR REVIEW PRIOR TO | | | INSTALLING ANY GEAR OR CALLING | | | INSPECTION ON THE SERVICE. | | | | | | SUBMIT TWO SETS OF AIC CALCULATIONS AND | | | INDICATE COMPLIANCE WITH ARTICLE 110.9 | | | STATE THE RATING OF THE EQUIPMENT. | | | A LETTER AND CALCS SUBMITTED ON A 8 1/2" | | | X 11", SIGNED AND SEALED WILL SUFFICE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
16:32 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-06-09 |
Time |
07:05 |
Sent To |
M |
|
| Notes |
| 2004-06-09 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} A TITLE BLOCK IS REQUIRED PER 61G15- | | | 23.002, PLEASE INCLUDE ALL LICENSE | | | #'S ON THE REQUIREDBLOCK. | | | PLEASE ALSO INCLUDE CERTIFICATE OF | | | AUTHORIZATION #'S WHERE REQUIRED. | | | | | | 2} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALLED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BE RATED FOR THE AVAILABLE FAULT | | | CURRENT PER 110.9. | | | | | | 3} THE GROUNDING ELECTRODE CONDUCTOR | | | MUST BE SIZED PER 250.66 (# 2). | | | | | | 4} THE RANGE (OVEN) MUST BE CALCULATED | | | PER 220.19 (8000 VA., MIN). | | | | | | 5} PLEASE LIST ALL THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE PER 210.11(C)(3). | | | | | | 6} PROVIDE A RECEPTACLE FOR THE SERVICE | | | OF THE A/C EQUIPMENT PER 210.63. | | | | | | 7} A SMOKE DETECTOR IS REQUIRED IN | | | PROXIMITY TO THE STAIRS LEADING TO THE | | | 2ND FLOOR PER 905.2.2 FBC & NFPA-72 | | | 8-1.4.1.6.2. | | | | | | 8} SEE NOTE REFERRING TO200 AMP PANEL | | | AND LOCATION ARROW, CORRELATE WITH | | | CORRECT LOCATION. | | | | | | 9} THE NOTE REFERRING TO THE AHU-2 | | | DISCONNECT " ABOVE" IN THE HALL CLOSET | | | 2ND FLOOR, MUST COMPLY WITH 424-19(A), | | | "IN SIGHT OF". | | | | | | 10} A RECCEPTACLE MUST BE ADDED TO THE | | | REAR OF THE RESIDENCE TO COMPLY WITH | | | 210.52(E). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-02 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-26 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | NEW CONSTR ONLY NOT DEMO PER S PILAND | | | DEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
13:50 |
Sent To |
E |
|
| Notes |
| 2005-06-21 00:00:00 | TO "BTROBAUG" DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
13:49 |
Sent To |
M |
|
| Notes |
| 2005-06-21 00:00:00 | TO "M" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2005-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-06-21 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-06-21 |
Time |
13:48 |
Sent To |
P |
|
| Notes |
| 2005-06-21 00:00:00 | TO "P" BOX/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2005-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-05-06 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-05-06 |
Time |
13:39 |
Sent To |
B |
|
| Notes |
| 2005-05-06 00:00:00 | TO "RMCDOUGAL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-12-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-29 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-29 |
Time |
12:52 |
Sent To |
P |
|
| Notes |
| 2004-12-29 00:00:00 | TO "P" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-18 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-18 |
Time |
17:31 |
Sent To |
B |
|
| Notes |
| 2004-10-18 00:00:00 | TO RM DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-18 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-06 |
Time |
14:31 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-29 |
Time |
16:32 |
Sent To |
E |
|
| Notes |
| 2004-07-29 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-07-29 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-29 |
Time |
09:07 |
Sent To |
Z |
|
| Notes |
| 2004-07-29 00:00:00 | TO MM RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2004-06-28 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2004-05-27 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | TO SFD RACK/E/PER MM PASS ON TO TRADES | | | THEN BACK TO PLANNING AS GRACE ON VAC | | 2004-05-27 00:00:00 | TO Z |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-07-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-07-06 |
Time |
11:40 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-07-06 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-16 |
Time |
11:03 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-08-16 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-14 |
Time |
12:28 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-06-14 |
Time |
08:30 |
Sent To |
P |
|
| Notes |
| 2004-06-14 00:00:00 | PROVISO: | | | 2001 FBC(M) 307.2.3: | | | AUXILIARY DRAIN PAN SHALL HAVE OVERFLOW | | | PROTECTION BY MEANS OF A FLOAT SWITCH OR | | | AUXILIARY DRAIN LINE TERMATING AT A | | | CONSPICUOUS POINT.INDICATE TERMINATION | | | OF THE AUXILIARY DRAIN LINE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2005-07-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-07-19 |
Time |
08:48 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2005-07-19 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2005-07-19 00:00:00 | REVISION OK | | | | | | UNABLE TO FIND FILE COPY OF MEP'S - TWO | | | ADDRESSES 506 & 502 FOR SAME JOB. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-01-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-01-08 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-01-08 |
Time |
12:04 |
Sent To |
PC |
|
| Notes |
| 2005-01-08 00:00:00 | REVISION: APPROVED PER NOTE FROM KS | | | DATED 08-14-04PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2004-08-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-14 |
Time |
12:28 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-14 |
Time |
12:28 |
Sent To |
M |
|
| Notes |
| 2004-08-14 00:00:00 | PASSED/PROVISO | | | | | | LAUNDRY SINK SHALL DISCHARGE DOWNSTREAM | | | OF THE WET VENT. 909.1 - REVISION REQUI- | | | RED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-04 |
Time |
10:56 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2004-06-17 |
Time |
18:44 |
Sent To |
B |
|
| Notes |
| 2004-06-17 00:00:00 | DENIED; | | | 1.SANITARY RISER DIAGRAM NOT TO CODE. | | | SEE RED LINES ON RISER DIAGRAM. W/C'S | | | ON 1ST FLOOR ARE NOT VENTED, W/M TO | | | DISCHARGE DOWN STREAM OF THE WET VENT | | | OF 1/2 BATH. 909.1 | | | 2.DELETE GAS PIPE RISER. GAS CONTRACTOR | | | TO SUBMIT PLANS WITH APPLICATION. | | | 3.W/H PAN REQUIRES A DRAIN TO THE | | | OUTSIDE OF BUILDING. 504.8.1 & 2. | | | 4.THERMAL EXPANSION CONTROL REQUIRED | | | PER. 607.3 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2004-11-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-11-19 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-11-19 |
Time |
13:41 |
Sent To |
B |
|
| Notes |
| 2004-11-19 00:00:00 | NOTE: APPROVE BY GRACE JOYCE, PLANNER | | | 822-1447. PLANS GIVEN TO RMCDOUGAL TO | | | ISSUE PERMIT MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2004-10-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-10-18 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-10-18 |
Time |
10:01 |
Sent To |
I |
|
| Notes |
| 2004-10-18 00:00:00 | DENIED, NEED TO PROVIDE CROSS ACCESS | | | AGREEMENT TO ALLOW ONE DRIVEWAY FOR | | | BOTH LOT.3RD REQUEST. GRACE JOYCE, | | | PLANNER 822-1447 MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-06 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-07-29 |
Time |
15:52 |
Sent To |
I |
|
| Notes |
| 2004-07-29 00:00:00 | DENIED, NEED TO PROVIDE CROSS ACCESS | | | AGREEMENT TO ALLOW ONE DRIVEWAY FOR BOTH | | | LOT.CALLED STEVE CURRY AND LEFT MSG. | | | GRACE JOYCE, PLANNER 822-1447 MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-29 |
Time |
09:07 |
Rev Time |
0.25 |
| Received By |
gjoyce |
Date |
2004-06-24 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2004-06-24 00:00:00 | NEED CROSS ACCESS AGREEMNET TO ALLOW | | | ONE DRIVEWAY FOR BOTH LOTS LEFT MESSAGE | | | WITH STEVE CURRY 722-0881 |
|
|