Plan Review Details - Permit 04051041
Plan Review Stops For Permit 04051041
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-07-16 Cont ID  
Sent By jwitmer Date 2004-07-16 Time 11:16 Rev Time 0.55
Received By jwitmer Date 2004-07-16 Time 11:16 Sent To PC
Notes
2004-07-16 00:00:00REVISION: STEM WALL, FOUNDATION,
 SLAB & HANDRAIL.
 BUILDING PROVISO: NEW DOOR REQUIRES
 STATEWIDE PRODUCT TESTING REPORT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-06-25 Cont ID  
Sent By csiegber Date 2004-07-15 Time 15:26 Rev Time 0.33
Received By jwitmer Date 2004-06-25 Time 16:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-16 Cont ID  
Sent By jwitmer Date 2004-06-16 Time 11:45 Rev Time 1.22
Received By jwitmer Date 2004-06-16 Time 11:45 Sent To PC
Notes
2004-06-16 00:00:00BUILDING PLAN REVIEW
 PERMIT: 04051041
 ADD: 2400 CENTREPARK WEST# 101
 CONT: CAPITAL CONSTRUCTION SERVICES
 TEL: (954) 782-9222
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2)TABLE 704.1 OCCUPANCY SEPERATION
 REQUIREMENTS;
 S2: LOW HAZARD REQUIRES 2 HR WALLS
 PROVIDE UL LISTING OR US GYPSOM
  
 3) WAREHOUSE TO MERCANTILE, THIS WARE-
 HOUSE OCUPANCY REQUIRES 2 HR WALL, 1 1/2
 HR OPOENING PROTECTIVES.
  
 4)704.2.1.4 CORRIDOR PARTITIONS, SMOKE
 STOP PARTITIONS, HORIZONTAL EXIT PART-
 ITIONS, EXIT ENCLOSURES, AND FIRE
 RATED WALLS REQUIRED TO HAVE PROTECTED
 OPENINGS SHALL BE EFFECTIVELY AND
 PERMANETLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE
 AUTHORITY HAVING JURISDICTION. SUCH IDEN
 TIFICATION SHALL BE ABOVE ANY DECORATIVE
 CEILING CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING" FIRE & SMOKE BARRIER
 PROTECT ALL OPENINGS".
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-25 Cont ID  
Sent By dpalmer Date 2004-06-25 Time 06:23 Rev Time 0.33
Received By dpalmer Date 2004-06-25 Time 06:05 Sent To  
Notes
2004-06-25 00:00:00NOTED
  
 250.30,250.24

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-06-02 Cont ID  
Sent By dpalmer Date 2004-06-02 Time 12:54 Rev Time 0.50
Received By dpalmer Date 2004-06-02 Time 12:54 Sent To  
Notes
2004-06-02 00:00:00************* UNSAT **************
  
 1 )NOTE: PLEASE SHOW LOAD CALCULATIONS,
 PLEASE SHOW PER
 220.3,220.10,220.11,220.13 ETC.
 PLEASE ALSO SHOW ALL CONTINOUS LOADS
 AT 125% PER 215.3,230.42
  
 2)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS CORRELATE WITH THE SUBMITTED PANEL
 SCHEDULE. PLEASE CIRCUIT EM/EXT LTS
 PER 700.12E.
  
 3)NOTE: PLEASE SEE PLANS SHOW TWO NEW
 PANELS, YET RISER INDICATE ONLY ONE.
 RISER INDICATES A NEW 200A DISC, IS THIS
 THE 200A PANEL?
  
 4)NOTE: PLEASE METHOD OF EQUIPMENT
 GRONDING BETWEEN MAIN DISC AND PANEL.
 250.110/250.24 PER 250.122
  
 5)NOTE: PLEASE SEE RISER AND ELEC RM
 LAYOUT. LAYOUT SHOWS MANY MORE PANELS
 THAN ON RISER?
 PLEASE SHOW SIZE OF EXISTING SERVICE
 AND SERVICE ENT CONDUCTORS.215.5
  
 6)NOTE: PLEASE SEE FS 481.221 WHICH ALSO
 REQ'S ARCH TO DATE PLANS WHEN SIGNED AND
 SEALED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-06-29 Cont ID  
Sent By nmccray Date 2004-06-29 Time 13:35 Rev Time 0.00
Received By nmccray Date 2004-06-29 Time 13:35 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-05-26 Cont ID  
Sent By mcarsill Date 2004-05-26 Time 12:21 Rev Time 0.00
Received By mcarsill Date 2004-05-26 Time 12:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-08-20 Cont ID  
Sent By csiegber Date 2004-08-20 Time 14:39 Rev Time 0.00
Received By csiegber Date 2004-08-20 Time 14:39 Sent To P
Notes
2004-08-20 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-07-15 Cont ID  
Sent By csiegber Date 2004-07-15 Time 15:26 Rev Time 0.00
Received By csiegber Date 2004-07-15 Time 15:26 Sent To B
Notes
2004-07-15 00:00:00TO JW DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-06-24 Cont ID  
Sent By csiegber Date 2004-06-24 Time 12:24 Rev Time 0.00
Received By csiegber Date 2004-06-24 Time 12:24 Sent To  
Notes
2004-06-24 00:00:00TO COMM BD#9

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-16 Cont ID  
Sent By csiegber Date 2004-06-24 Time 12:24 Rev Time 0.00
Received By csiegber Date 2004-05-26 Time 08:49 Sent To  
Notes
2004-05-26 00:00:00TO COMM BD. #42

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-07-06 Cont ID  
Sent By csiegber Date 2004-08-20 Time 14:39 Rev Time 1.00
Received By kstevens Date 2004-07-03 Time 17:20 Sent To  
Notes
2004-07-06 00:00:00PER ARCHITECT - HIGH LOW DRINKING FOUNT-
 AIN - OK TO REMOVE 2ND LAV FROM RISER
 DIAGRAM TO REFLECT THE FLOOR PLAN. 7-6-4

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-06-15 Cont ID  
Sent By kstevens Date 2004-06-15 Time 16:52 Rev Time 1.00
Received By kstevens Date 2004-06-15 Time 16:52 Sent To  
Notes
2004-06-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SHT A-2 SHOW CLEAR FLOOR SPACE FOR
 THE W/C 11-4.16.2, THE LAV 11-4.19.3, &
 THE DRINKING FOUNTAIN WITH CLEARANCES
 11-4.15.5.
 2) SHT A2 HANDICAP BATHROOM REQUIREMENTS
 SHOW THE FOLLOWING ON DETAILS:
 - TOILET TO BE 17" TO 19" - SHOWS 20"
 SECTION 11-4.16.3
 - LAVS TO BE 34" TO RIM SECTION 11-4.19
 .2
 - SHOW FLUSH CONTROLS FOR W/C SECTION
 11-4.16.5
 - SHOW EXPOSEC PIPES AND SURFACES SEC
 11-4.19.4
 - SHOW DRINKING FOUNTAIN SPOUT HEIGHT
 SECTION 11-4.15.2
 - SHOW DRINKING FOUNTAIN CLEARANCES
 SECTION 11-4.15.5
 - SHOW COMPLIANCE FOR THOSE WHO HAVE
 DIFFICULTY BENDING OR STOOPING. SECTION
 11-4.1.3(10)(A)
 3) SHT A-2 SHOWS W/C AT 15" OFF WALL TO
 CENTER OF FIXTURE. 18" REQUIRED SEE FIG.
 28.
 4) SUBMIT A WATER RISER DIAGRAM. SECTION
 104.3.1.1
 5) SHT A-2 SANT. RISER DIAGRAM, DRINKING
 FOUNTAIN IS NOT SHOWN ON RISER. RISER
 DIAGRAM SHALL REFLECT THE FLOOR PLAN.
 SECTION 104.2.1
 6) THE DATE THAT THE SEAL AND SIGNATURE
 ARE AFFIXED SHALL APPEAR BELOW THE SIG-
 NATURE ON EACH SHEET. FAC 61G1-16.003 &
 FS 481.2055
 7) A SPACE FOR THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT. FAC
 61G1-16.004(6) & FS 481.2055
  
 REVIEW BY KEN STEVENS