| Plan Review Stops For Permit 04051005 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-10-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-10-13 |
Time |
14:19 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-10-13 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2004-10-13 00:00:00 | REVISIONS 1&2 DATED 8/25/04 | | | A201, A211, A221, A222, A301 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-08-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-10 |
Time |
12:40 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-08-10 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2004-08-10 00:00:00 | SEE PROVISO ON PLAN RE: STAIR DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-08-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-09 |
Time |
13:08 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-08-09 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2004-08-09 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE SEAL IS TO BE DATED. | | | | | | ****NO RESUB FEE**** |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
15:35 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-07-15 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2004-07-15 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | 1.)THE SEAL IS TO BE DATED, FS481.221. | | | | | | 2.)SEE OTHER REVIEWER'S NOTES IN | | | REGARDS TO PRINTED LICENSE REQUIREMENTS. | | | | | | 3.)REGARDING PREVIOUS COMMENT #1, AND | | | OUR TELEPHONE DISCUSSION THAT IT WOULD | | | BE REDLINED IF NECESSARY, PLEASE NOTE | | | THAT I WAS UNABLE TO FIND AN EXCEPTION | | | TO THIS REQUIREMENT FBC412.8.1.AS THE | | | OTHER REVIEWS HAVE FAILED, PLEASE MAKE | | | THE CHANGE AT THIS TIME OR CONTACT ME | | | IF YOU ARE ABLE TO FIND AN EXCEPTION TO | | | THIS REQUIREMENT. | | | | | | 4.)WHEN RESUBMITTING, REPLACE ONLY | | | SHEETS WHICH HAVE CHANGED.SUBMIT OLD | | | SHEETS SEPARATELY TO EXPEDITE PLAN | | | REVIEW. | | | | | | 5.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE | | | A PERMIT CAN BE ISSUED. | | | | | | 6.)THE ORIGINAL PERMIT APPLICATION | | | IS NO LONGER IN THE PACKAGE.PLEASE | | | ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-06-18 |
Time |
16:00 |
Rev Time |
2.00 |
| Received By |
shill |
Date |
2004-06-18 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)FBC412.8.1, ALL STAIRWAY DOORS | | | WHICH ARE TO BE LOCKED FROM THE STAIR- | | | WAY SIDE SHALL HAVE THE CAPABILITY OF | | | BEING UNLOCKED UPON ACTIVITION OF THE | | | SPRINKLER SYSTEM OR UPON POWER FAILURE. | | | | | | 2.)DOOR 902 IS TO COMPLY WITH | | | FBC FIG 25, CHAPTER 11 (MANEUVERABILITY) | | | | | | 3.)SEE OTHER REVIEWER'S COMMENTS IN | | | REGARDS TO TITLE BLOCK ISSUES. | | | | | | 4.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-10-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-10-14 |
Time |
14:20 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-10-14 |
Time |
13:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
14:51 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-09-21 |
Time |
20:23 |
Sent To |
|
|
| Notes |
| 2004-09-21 00:00:00 | ********* UNSAT ******* | | | | | | 1)NOTE: PLEASE SEE J-BOX'S IN CONFERENCE | | | ROOM WITH NEW CIRCUITS SHOWN TO PANEL | | | "N". PLEASE SEE CIRCUITS SHOWN ARE | | | ALREADY USED ON POWER PLAN? | | | PLEASE CLARIFY ANY NEW CIRCUITS FOR | | | REVISED AREAS. | | | PLEASE ALSO CORRELATE CIRCUITS ON PLANS | | | AND PANEL SCHEDULE. | | | | | | 2)NOTE: PLEASE SEE ARCH FIRM MISSING | | | CA # IN TITLE BLOCK FOR TRADE PLANS. | | | SHOWN ON ARCH. O.K. | | | FAC 61G1-16.004 | | | | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFECT ON | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | INSERT NEW SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-08-03 |
Time |
08:22 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-08-03 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-07-02 |
Time |
16:40 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-07-02 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2004-07-02 00:00:00 | ********* UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE NOTE #2 FROM FIRST | | | REVIEW. TITLE BLOCK NO CONTAINS INFOR- | | | -MATION STATING FLORIDA CERTIFICATE OF | | | AUTHORIZATION # AS AR0015003. THIS IS | | | THE ARCH'S FL REGISTRATION #, NOT THE | | | FIRM'S REQUIRED CERTIFICATE OF AUTHORIZ- | | | -ATION NUMBER. PLEASE SEE FS 481.219 | | | WHICH REQUIRESTHIS LICENSE #. | | | PLEASE ALSO SEE FAC 61G1-16.004 WHICH | | | REQUIRES THIS TO BE INCLUDED ON TITLE | | | BLOCK. | | | PLEASE SEE THIS COMMENT IS FOR ALL SHEET | | | -S , WHEATHER OR NOT COMMENT IS MADE BY | | | OTHER REVIEWERS. | | | AT TIME OF REVIEW ONLY THE ARCH'S # | | | AS REFERENCED ON PLANS AS BEING THE | | | STATE CA # WAS FOUND ONLINE WITH DBPR. | | | | | | PLEASE SEE THAT NO PERMIT APPLICATION | | | WAS SUBMITTED BACK WITH RESUB. THIS | | | MUST BE BROUGHT BACK IN FOR PROCESSING | | | AND FOR REVIEWS TO BE COMPLETED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-02 |
Time |
12:21 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2004-06-02 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2004-06-02 00:00:00 | ******* UNSAT ****** | | | | | | 1) NOTE: PLEASE SHOW ALL CONTINUOUS LOAD | | | -S AT 125%(LIGHTING ETC)(LARGEST MOTORS) | | | 215.2,215.3,230.42,210.19A,210.20A ETC | | | | | | 2)NOTE: PLEASE SEE FS 481.219, FAC | | | 61G1-16.004. PLEASE INCLUDE ALL LICENSE | | | INFORMATION ON TITLE BLOCK(S). THIS | | | NOTE IS FOR ARCH FIRM. THIS IS REQ'D ON | | | ALL SHEETS WHEATHER OR NOT COMMENT IS | | | MADE FROM OTHER REVIEWER(S). | | | | | | 3)NOTE: PLEASE SEE IMPRESSION TYPE SEAL | | | IS REQ'D TO BE CLEAR AND VISABLE WITH | | | ALL INFORMATION ON SAID SEAL. | | | PLEASE SEE SOME SHEETS ARE FAINT AND | | | UNCLEAR. | | | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWERS | | | AS THEY MAY AFFECT ELECTRICAL PLANS. | | | | | | PLEASE ALSO REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-10-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-10-01 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-10-01 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2004-07-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-07-28 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-07-28 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2004-07-08 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-07-08 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-07-08 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2004-07-08 00:00:00 | PLANS HAS MET CODE COMPLIANCES PLEASE | | | SEE ELECTRICAL AND MECHANICAL REVIEWS. | | | | | | NATE MCCRAY, CAPTAIN | | | 835-2910 OR 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-05-25 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-05-25 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2004-05-25 00:00:00 | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2) DEBRIS SHALL BE REMOVED FROM THE | | | BUILDING DAILY. | | | | | | 3) ALL EXITWAYS SHALL REMAIN CLEAR | | | AND ACCESSIBLE. | | | | | | 4) DOOR SWING APPEARS TO BE INCORRECT | | | ON ONE OF THE EXISTING STAIRTOWERS. | | | | | | 5) PLEASE CLARIFY # 8 ON PAGE A211. | | | ANY LOCKING DEVICES INSTALLED ON | | | EXIT DOORS SHALL COMPLY WITH | | | SPECIAL LOCKING ARRANGEMENTS AS PER | | | THE 2000 EDITION OF THE LIFE SAFETY | | | CODE. PLEASE PROVIDE MORE DETAILS. | | | | | | 6) WHAT FIRE RATING IS PRESENT FOR | | | THE HERCULITE DOORS PLANNED FOR THE | | | ELEVATOR LOBBY. | | | | | | 7) HOW IS FIRE RESCUE EXPECTED TO | | | ENTER THE SPACE SHOULD THE FIRE ALARM | | | SYSTEM OR SPRINKLER SYSTEM NOT BE | | | OPERATING WITH THE PROPOSED INSTALLATION | | | OF SECURITY DEVICES. | | | | | | 8) PLEASE SHOW ALL REQUIRED DIMENSIONS | | | BETWEEN WORK STATIONS THAT WILL BE | | | USED FOR EXITING. | | | | | | 9) FIRE ALARM NOTES # 16 AND # 18 | | | ARE INCORRECT. FIRE ALARM CIRCUITS | | | SHALL BE CLASS A, STYLE D AND DUCT | | | SMOKE DETECTORS WHEN ACTIVATED SHALL | | | INITIATE AN ALARM CONDITION NOT A | | | TROUBLE CONDITION. PLEASE REVISE | | | PLANS. | | | | | | 10) NO MANUAL PULL STATION NOTED AT | | | EXIT STAIR NEAR COPY AREA. SEPARATE | | | PLANS AND PERMITS REQUIRED FOR | | | FIRE ALARM SYSTEM REMODEL. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-10-07 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-10-07 |
Time |
14:51 |
Sent To |
E |
|
| Notes |
| 2004-10-07 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-09-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-09-15 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-09-15 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2004-09-15 00:00:00 | TO COMM BD#29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2004-07-22 00:00:00 | TO COMM BD#35 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2004-06-25 00:00:00 | TO COMM BD#31 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-24 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-24 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2004-05-24 00:00:00 | TO COMM BD #10 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-10-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-10-07 |
Time |
07:25 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-10-07 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-08-05 |
Time |
14:50 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2004-08-05 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2004-07-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-07-06 |
Time |
11:30 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-07-06 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2004-07-06 00:00:00 | DENIED: | | | PLANS ARE CODE COMPLIANT WITH THE | | | EXCEPTION FOR THE TITLE BLOCK.PLEASE | | | PROVIDE CERTIFICATE OF AUTHORIZATION # | | | AS REQUIRED BY THE FLORIDA STATUTE AND | | | THE FLORIDIA ADMISTRATIVE CODE. | | | | | | PROVIDE ORIGINAL PERMIT APPLICATION | | | WITH RE-SUBMITTAL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-10 |
Time |
06:49 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2004-06-09 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | DENIED: | | | 1.PLEASE CLARIFY LOCATION & ACCESS TO | | | THE CONDENSING UNIT FOR THE NEW 3 TON | | | LIEBERT SYSTEM. | | | | | | 2.THE CONDENSING UNIT STAND SHALL HAVE | | | A MINIMUM CLEARANCE BETWEEN THE ROOF | | | SURFACE & THE BOTTOM OF THE SUPPORT RAIL | | | IN ACCORDANCE WITH 2001 FBC 1511.7 | | | (SEE ATTACHED). | | | | | | 3.PLEASE CLARIFY NEW OR EXISTING FIRE | | | DAMPERS. | | | | | | SEE ALSO COMMENT #2 BY DEWEY PALMER, | | | ELECTRICAL PLAN REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2004-10-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-10-06 |
Time |
17:39 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-10-06 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2004-10-06 00:00:00 | REVISION OK - SHTS P1, P2, & P3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-07 |
Time |
14:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-08-07 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-07-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-07-10 |
Time |
16:30 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2004-07-10 |
Time |
16:30 |
Sent To |
|
|
| Notes |
| 2004-07-10 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | FBC-2001 CHAPTER 11 | | | | | | 1) FROM PREVIOUS REVIEW: TITLE BLOCK | | | REQUIRES FIRM LICENSE, (CERTIFICATE OF | | | AUTHORIZATION). LICENSE FOR ARCHITECT IS | | | SHOWN AS CERTIFICATE OF AUTHORIZATION. | | | 2) SHT A231 ROOMS 931, 937, & 961 SHOW | | | CLEAR FLOOR SPACE FOR SINKS AND TURNING | | | AREA ON FURNITURE PLAN TO SHOW HOW THE | | | FURNITURE IMPACTS THE TURNING AREA AND | | | THE CLEAR FLOOR SPACE, - RESPONSE NOTED, | | | BUT THE CLEAR FLOOR SPACE AND THE TURN- | | | ING AREA ARE REQUIRED TO BE ON THE FLOOR | | | PLAN, NOT JUST THE TURNING AREA. | | | 3) THE PERMIT APPLICATION WAS NOT SUB- | | | MITTED WITH PLANS. THIS WILL BE REQUIRED | | | FOR PERMIT TO BE ISSUED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-15 |
Time |
15:29 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2004-06-15 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2004-06-15 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1) ARCHITECTURAL SHEETS, TITLE BLOCK RE- | | | QUIRES FIRM LICENSE NUMBER, DATE PREPAR- | | | ED, PRINTED NAME OF PERSON SEALING DOCU- | | | MENT, AND CERTIFICATE OF AUTHORIZATION | | | NUMBER. FAC 61G1-16.004 & FS 481.219 | | | 2) SINKS SHALL COMPLY WITH SECTION 11-4. | | | 24 AND ALL SUBSECTIONS. SUBMIT A DETAIL | | | KNEE CLEARANCE 11-4.24.3, DEPTH 11-4.24. | | | 4, EXPOSED PIPES AND SURFACES 11-4.24.6, | | | 3) SHT A231 ROOMS 931, 937, AND 961, | | | SHOW CLEAR FLOOR SPACE 11-4.24.4 AND A | | | TURNING AREA 11-4.2.3 ON FURNITURE PLAN | | | TO SHOW HOW FURNITURE IMPACTS THE CLEAR | | | FLOOR SPACE AND THE TURNING AREA. | | | 4) SHT P3 PLUMBING SPECIFICATIONS: 7 & 8 | | | AIR CHAMBERS ARE NOT APPROVED. DELETE | | | FROM REFERENCES. | | | 5) SHT P3 WATER RISER DIAGRAMS. SHOW THE | | | LOCATION FOR THE WATER HAMMER ARRESTORS | | | REQUIRED BY SECTION 604.9. (AT ICE | | | MAKERS). SHOW LOCATION AT FIXTURE NOT IN | | | THE CEILING. PDI-WH 201 & MANUF. INSTALL | | | INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|