| Plan Review Stops For Permit 04050920 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2004-06-23 |
Time |
13:30 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-06-23 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
vmahle |
Date |
2004-06-23 |
Time |
11:05 |
Rev Time |
1.00 |
| Received By |
lsmith |
Date |
2004-06-03 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | BUILDING PLAN REVIEW: FAILED: | | | | | | 1.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | WWW.FLORIDABUILDING.ORG | | | 1. ROOF MATERIALS | | | 2. GLASS BLOCK | | | 3. STRUCTURAL COMPONENTS (TRUSS | | | BUCKETS, ETC.) | | | | | | 2. SURVEY NEEDS TO SHOW NEW ADDITION | | | WITH SETBACKS. | | | | | | 3. NEED SEPARATE ROOFING PERMIT. ROOFER | | | NEEDS TO SUBMIT STATE PRODUCT APPROVALS | | | FOR METAL ROOF & COMPONENTS. | | | | | | 4. NEED SEPARATE PERMITS FOR IRRIGATION. | | | | | | 5. NEED SEPARATE PERMIT FOR DRIVEWAY | | | APPROACH. | | | | | | 6. NEED TO APPLY FOR AN EASEMENT | | | RELEASE FORM FOR THE NEW FENCE.NEED | | | FENCE PERMIT. | | | | | | 7. SHOW A SEPARATE SECTION OF THE TIE-IN | | | OF THE ROOF TRUSSES (SEE SECTION 4/2) | | | WITH MORE DETAIL. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUIDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
vmahle |
Date |
2004-06-23 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
vmahle |
Date |
2004-06-23 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-18 |
Time |
10:36 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-05-26 |
Time |
11:07 |
Sent To |
P |
|
| Notes |
| 2004-05-26 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} SHOW THE GROUNDING ELECTRODE SYSTEM | | | ON THE RISER DIAGRAM FOR COMPLIANCE | | | WITH 250.50 & 250.66. | | | | | | 2} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING | | | INSTALLED. MAINS/BRKRS AND PANELS ARE | | | ALL TO BE RATED FOR THE AVAILABLE FAULT | | | CURRENT PER 110.9. | | | | | | 3} INDICATE CONDUCTOR AND CONDUIT SIZE | | | AND TYPE FOR THE SERVICE PER 230.41 & | | | 42. | | | | | | 4} INDICATE THE MEANS OF DISCONNECT FOR | | | THE SERVICE PER 230.70. | | | | | | 5} PLEASE LIST ALL THE REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | | SCHEDULE. PER 210.52D, 210.11C3 | | | | | | 6} PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUIT(S) ON PANEL | | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | | IN BEDROOMS ARE TO BE PROTECTED. | | | | | | 7} THE SMALL APPLIANCE CIRCUITS MUST BE | | | CALCULATED @ 1500VA EACH PER 220.16(A). | | | | | | 8} THERE MUST BEA DISCONNECTING MEANS AT | | | THE A/C CONDENSER PER 440.14, AND A | | | RECEPTACLE PER 210.63. | | | | | | 9} A SMOKE DETECTOR MUST BE LOCATED IN | | | THE SLEEPING ROOM PER 8-1.4.1.6.2 | | | NFPA-72. | | | | | | 10} A RECEPTACLE MUST BE ADDED IN THE | | | BEDROOM TO COMPLY WITH 210.52(A)(1) | | | SPACING. | | | | | | 11} THE DINING ROOM MUST BE ON A SMALL | | | APPLIANCE CIRCUIT PER 210.52(B)(1). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-18 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-18 |
Time |
10:36 |
Sent To |
E |
|
| Notes |
| 2004-06-18 00:00:00 | TO BT DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-17 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-17 |
Time |
10:20 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-25 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-25 |
Time |
13:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2004-05-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-24 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-20 |
Time |
14:12 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-05-29 |
Time |
11:21 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2004-06-02 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
| 2004-06-02 00:00:00 | NO MECHANICAL PLANS SUBMITTED.NOTE ON | | | FLOOR PLAN 1 INDICATES A/C CONTRACTOR TO | | | PROVIDE PLANS AND SPECIFICATIONS. | | | ENERGY CALCULATIONS PROVIDED WITH | | | BUILDING PERMIT |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2004-05-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-05-26 |
Time |
13:14 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2004-05-29 |
Time |
11:21 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2004-06-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-17 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-17 |
Time |
16:01 |
Sent To |
I |
|
| Notes |
| 2004-06-17 00:00:00 | NOTE: MUST PULL A SEPARATE PERMIT FOR | | | FENCE WITH UTILITY APPROVAL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2004-05-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-24 |
Time |
13:05 |
Sent To |
I |
|
| Notes |
| 2004-05-24 00:00:00 | DENIED, NEED TO PROVIDE ADDITION ON | | | SURVEY WITH SETBACKS AND PROVIDE | | | DIMENSION FOR NEW DRIVEWAY (MUST MEET | | | 1000SQ FT OR 75% OF LANDSCAPE IN THE | | | FIRST 25FR FRONT SETBACK).CALLED CONTR |
|
|