Plan Review Details - Permit 04050869
Plan Review Stops For Permit 04050869
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-08-03 Cont ID  
Sent By jgomez Date 2004-08-03 Time 08:33 Rev Time 3.00
Received By jgomez Date 2004-08-03 Time 08:33 Sent To PC
Notes
2004-08-03 00:00:00BUILDING REVIEW PROVISO:
 PROVIDE ALL INFORMATION PRIOR TO INSTA-
 LLATION TO AVOID DELAYS OR CONFLICTS)
  
 1-SPECIFY UL LISTED ASSEMBLY FOR ONE HR
 FIRE RATED GLASS BLOCK ASSEMBLY TO BE
 USED AND REVISE GLASS BLOCK DETAIL ON
 SHEET A4 TO MATCH SUCH ASSEMBLY. TABLE
 600 FBC 2001 AND SECTION 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 2-SOIL TEST REPORT TO HAVE ENGINEER'S
 ORIGINAL SIGNATURE & DATE AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES.
 3-PRODUCT APPROVAL FOR FIXED WINDOW:
 A)PROVIDE LEGIBLE DRAWINGS.
 B)CLEARLY INDICATE ON PLANS WINDOWS TO
 HAVE TEMPERED GLASS, SINCE ACCORDING
 TO PRODUCT APPROVAL THEY ARE THE ONLY
 ONES TO MEET THE DESIGN PRESSURES
 CALCULATED ON MOST OF THE OPENINGS.
 C)NEED PRODUCT APPROVAL FOR LARGER
 WINDOWS AS SHOWN ON PLANS. SEE PRODUCT
 FOR MAX. WIDTH AND HEIGHT ALLOWED.
 4-IF OUTSWING FRENCH DOORS WILL BE USED,
 THEN REVISE PLANS TO MATCH ACCORDINGLY
 5-PROVIDE PRODUCT APPROVAL FOR MULLION
 TO BE USED FOR SLIDING GLASS DOORS W/
 TRANSOM ASSEMBLY. CLEARLY INDICATE
 MULLION SIZES & FASTENERS TO BE USED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 6-NEED PRODUCT APPROVAL FOR ENTRY DOOR.
 7-NEED PRODUCT APPROVAL FOR STRUCTURAL
 CONNECTORS USED ON THIS PROJECT.
 8-STORM SHUTTERS: REVISE KEY PLAN AND
 INSTALLATION SCHEDULE TO SHOW EGRESS
 OPENING REQUIRED BY SEC. 1005.4.5 FBC.
 9-TRUSS DRAWINGS PACKAGE: A)ENGINEER TO
 PROVIDE ORIGINAL SIGNATURE AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES.
 B)ENGINEER OF RECORD TO REVIEW & APPROVE
 THEM PRIOR TO SUBMITTAL.
 10-SHEET A4 AND S3 SHOW DIFFERENT SPECS
 FOR WINDOW & DOOR BUCKS. SPECIFY WHICH
 SPECS WILL BE USED.
 11-SHEET A5 AND S3. REVISE ALL NOTES.SEE
 CHAPTER 19 & 35 FOR SPECIFIC REFERENCE
 STANDARD AND EDITION TO BE REFERENCED
 ACCORDING TO FBC 2001.
 12-CONNECTOR SPECIFIED FOR TRUSSES AT
 ATRIUM AREA DON'T RESIST CALCULATED
 LOADS. SEE ENGINEERED TRUSSES FOR
 UPLIFT LOADS AND BEARING POINTS AND
 REVISE CONNECTOR AS REQUIRED.
 13-HANGER HU614 IS FOR WOOD TO WOOD
 CONNECTIONS. SPECIFY WOOD TO MASONRY
 HANGER AND SPECIFY FASTENERS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 14-CONNECTOR SPECIFIED FOR TRUSSES AT
 REAR PORCH NEED TO BE WOOD TO WOOD.
 CONNECTOR SPECIFIED IS TO BE EMBEDED
 IN CONCRETE. REVISE AS REQUIRED. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC.
 15-WINDOWS AT DINING AREA TO BE SAFETY
 GLASS AS REQ'D BY SEC. 2405.2.1(4)FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-08-02 Cont ID  
Sent By jgomez Date 2004-07-30 Time 16:46 Rev Time 3.00
Received By jgomez Date 2004-07-30 Time 16:46 Sent To PC
Notes
2004-07-30 00:00:00CHECKLIST:
 1-SPECIFY UL ASSEMBLY FOR ONE HR FIRE
 RATED GLASS BLOCK ASSEMBLY AT ZERO LOT
 LINE WALL. REVISE SPECIFICATIONS SHOWN
 ON DETAIL ON SHEET A-4 TO MATCH SUCH
 ASSEMBLY. SPECIFY FIRE RATED SEALANT
 AND GLASS BLOCK TYPE AND SIZE. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001
 AND TABLE 600 FBC 2001.
 2-SOIL TEST REPORT TO HAVE ORIGINAL
 SIGNATURES AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 3-PRODUCT APPROVAL FOR FIXED WINDOW:
 A)PROVIDE LEGIBLE DRAWINGS.
 B)DESIGN PRESSURES DON'T MEET THE DESIGN
 PRESSURES CALCULATED BY ENGINEER OF
 RECORD UNLESS USING TEMPERED GLASS.
 SPECIFY IF USING TEMPERED GLASS.
 C)NEED PRODUCT APPROVAL FOR LARGER
 WINDOWS AS SHOWN ON PLANS.
  
 4-SUBMITTED FRENCH DOOR PRODUCT APPROVAL
 IS FOR OUTSWING DOORS. PLANS SHOW
 INSWING DOORS. NEED PRODUCT APPROVAL
 FOR INSWING DOORS OR REVISE PLANS.
 5-PROVIDE PRODUCT APPROVAL FOR SLIDING
 GLASS DOORS WITH TRANSOM ABOVE SINGLE
 ASSEMBLY AS SHOWN ON PLANS. SEE PLANS.
 6-PRODUCT APPROVAL FOR INSWING ENTRY
 DOOR W/ TRANSOM ABOVE SINGLE ASSEMBLY
 AS SOWN ON PLANS.
 7-NEED PRODUCT APPROVAL FOR STRUCTURAL
 CONNECTORS SPECIFIED ON PLANS.
 8-STORM SHUTTERS KEY PLAN SHOWS SHUTTERS
 ON ALL OPENINGS, BUT NEED TO PROVIDE
 EMERGENCY MEANS OF ESCAPE AS REQUIRED
 BY SEC. 1005.4.5 FBC 2001. SPECIFY ON
 PLANS WHICH OPENING WILL BE DEDICATED
 FOR EGRESS.
 9-TRUSS DRAWING PACKAGE:
 A)ENGINEER TO PROVIDE ORIGINAL SIGNATURE
 AND DATE AS REQUIRED BY CHAPTER 471
 FLORIDA STATUTES.
 B)TRUSS PACKAGE TO BE REVIEWED/APPROVED
 BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL TO THIS OFFICE.
 10-WINDOW AND DOOR BUCK DETAILS: SHEET
 A-4 & SHEET S-3 SHOW DIFFERENT SPECS.
 CLARIFY WHICH METHOD WILL BE USED.
 11-SHEET A5: REVISE/UPDATE NOTES. SEE
 CHAPTER 19 AND CHAPTER 35 FOR CORRECT
 STANDARDS AND EDITIONS TO BE USED.
 12-CONNECTOR SPECIFIED FOR TRUSSES AT
 ATRIUM AREA DON'T RESIST CALCULATED
 LOADS SHOWN ON ENGINEERED TRUSSES.
 SEE ENGINEERED TRUSSES AND REVISE
 CONNECTORS AS REQUIRED.
 13-HANGER HU614 IS FOR WOOD TO WOOD
 CONNECTIONS. NEED HANGER FOR WOOD TO
 MASONRY. REVISE AS REQ'D AND SPECIFY
 ALL FASTENERS. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 14-CONNECTOR SPECIFIED FOR TRUSSES ON
 TOP OF 2X12 WOOD BEAM AT REAR PORCH
 IS FOR WOOD TO MASONRY INSTALLATION.
 NEED WOOD TO WOOD CONNECTOR. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001
 15-WINDOWS AT DINING ROOM NEED TO BE
 SAFETY GLASS AS REQUIRED BY SECTION
 2405.2.1(4) FBC 2001.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-06-18 Cont ID  
Sent By btrobaug Date 2004-07-27 Time 14:55 Rev Time 3.50
Received By jgomez Date 2004-06-17 Time 16:04 Sent To PC
Notes
2004-06-17 00:00:00BUILDING REVIEW CHECKLIST:
 1-PROVIDE NOTICE OF COMMENCEMENT.
 2-ENGINEER TO HAVE HIS TITLE BLOCK WITH
 ALL HIS INFO. IN ALL DWGS AS REQ'D BY
 CHAPTER 471 FL. ST. INCLUDING FIRM
 REGISTRATION NAME AND NUMBER.
 3-AS PER BUILDING OFFICIAL ZERO LOT LINE
 HOUSES NEED TO HAVE RECORDED EASEMENT
 DEDICATED FOR EGRESS.
 4-GLASS BLOCK AT ZERO LOT LINE NEED TO
 BE ONE HR FIRE RATED ASSEMBLY AS REQ'D
 BY TABLE 600 FBC 2001. DWGS TO SPECIFY
 1HR FIRE RATED GLASS BLOCK ASSEMBLY &
 REVISE DETAIL ON SHEET A-4 TO MATCH
 SUCH ASSEMBLY. SPECIFY UL ASSEMBLY.
 5-PROVIDE ATTIC ACCESS AT GUEST ROOM
 AREA. SEC. 2309.6 FBC 2001
 **SPECIFY ATTIC ACCESS SIZE FOR MAIN
 ROOF. SEC. 2309.6 FBC 2001.
 6-DESIGN CRITERIA NEED TO INCLUDE 30PSF
 OR 10PSF ATTIC LIVE LOAD AS REQUIRED
 BY TABLE 1604.1 FBC 2001.
 7-PROVIDE SOIL TEST REPORT.
 8-PROVIDE DETAIL/SECTION AND SPECS FOR
 CEILING INSTALLATION AT ENTRY AND REAR
 PORCHES. SEE ASTM C-926 & ASTM C-1063
 FOR SPECS, FASTENER SIZES & SPACING.
 9-PROVIDE COMPLETE FLORIDA OR LOCAL
 PRODUCT APPROVAL FOR:
 A)GARAGE DOOR THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER.
 B)WINDOW MULLIONS AND CLEARLY INDICATE
 ON DWGS COMPONENTS TO BE USED.
 C)SINGLE HUNG WINDOWS.
 D)FIXED WINDOWS.
 E)FRENCH DOOR AND PROVIDE ONLY PRODUCT
 APPROVAL FOR DOOR TO BE INSTALLED.
 F)SLIDING GLASS DOORS WITH TRANSOM ABOVE
 SINGLE ASSEMBLY AS SHOWN ON PLANS.
 G)GLASS BLOCK: 1 HR FIRE RATED ASSEMBLY.
 H)ROOF TILE.
 I)STRUCTURAL CONNECTORS.
 J)INSWING ENTRY DOORS WITH TRANSOM ABOVE
 SINGLE ASSEMBLY AS SHOWN ON PLANS.
 10-STORM SHUTTERS PACKAGE: A)PROVIDE KEY
 PLAN & COMPLETE INSTALLATION SCHEDULE.
 B)CLEARLY INDICATE ON DRAWINGS SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR TYPE &
 SPACING TO BE USED ACCORDING TO THE
 DESIGN PRESSURES, EDGE DISTANCE, PANEL
 SPAN, CONNECTION TYPE AND STRUCTURE TO
 BE ATTACHED TO (MASONRY OR CONCRETE)
 C)NEED FLORIDA OR LOCAL PRODUCT APPROVAL
 11-TRUSS DRAWINGS PACKAGE: A)ENGINEER TO
 PROVIDE ORIGINAL SIGNATURE, SEAL AND
 DATE AS REQUIRED BY CHAPTER 471 FL. ST
 B)COVER SHEET:*MISSING INFORMATION FOR
 STRUCTURAL ENGINEER OF RECORD.
 **SPECIFY ENCLOSURE CLASSIFICATION.
 C)TRUSS PACKAGE TO BE REVIEWED AND
 APPROVED BY ENGINEER OF RECORD.
 D)CHECK/REVISE HEIGHT OF PLATES. SEE
 STRUCTURAL DWGS FOR CORRECT HEIGHT.
 E)ADDRESS COMENTS TO TRUSS PACKAGE AND
 PROVIDE THIS INFORMATION TO BUILDING
 INSPECTOR FOR ROOF FRAMING INSPECTION.
 12-SHEET A-2: OPENING PRESSURES ARE
 CALCULATED BY PSF NOT PSI. REVISE NOTES
 13-SHEET A-4: A)REVISE WINDOW AND DOOR
 BUCK DETAILS TO COMPLY WITH SECTION
 1707.4.4.2 FBC 2001 TO PROVIDE FULL
 DOOR/WINDOW SUPPORT & NON BEVELED BUCK
 B)DOOR BUCK DETAIL: CLARIFY FASTENER TO
 BE USED. TAPCONS OR HILTI GUN NAILS?
 14-SHEET A-5: A)SEE CHAPTER 19 FBC 2001
 FOR CORRECT ACI SECTION REFERENCED.
 B)ROOF SHEATHING NOTES AND ATTACHMENT/
 FASTENER SPECS TABLE: CLARIFY/REVISE
 TO MATCH INFORMATION GIVEN ON SHEETS
 A2 AND A2.1 STRUCTURAL NOTES.
 15-SHEET S-2: A)REVISE/UPDATE TRUSS
 ANCHOR SCHEDULE TO COMPLY WITH SECTION
 1609.4.3 FBC 2001. SEE 2004 SIMPSON
 CATALOGUE WHICH HAVE REVISED VALUES &
 TYPE AND NUMBER OF FASTENERS TO COMPLY
 WITH THIS SECTION. PROVIDE COMPLETE
 ENGINEERING CALCS FOR TYPE AND NUMBER
 OF FASTENERS DIFFERENT THAN THOSE
 PUBLISHED BY MANUFACTURER. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 B)PROVIDE BEAM AND LINTEL SCHEUDLE. SEC.
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 C)CONNECTOR SPECIFIED FOR TRUSSES AT
 ATRIUM AREA DON'T RESIST CALCULATED
 LOADS. SEE ENGINEERED TRUSSES. ALSO,
 BEARING POINTS SHOWN DON'T MATCH THOSE
 DESIGNED ON ENGINEERED TRUSSES. REVISE
 AS REQUIRED. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 D)SHEATHING NOTE TO MATCH SPECS SHOWN ON
 SHEET A-2 AND A-2.1.
 E)WHERE IS SIMPSON HUC610 TAKEN FROM?
 UNABLE TO FIND IT IN 2004 CATALOGUE.
 IS THE THE RIGHT SIZE HANGER FOR (3)
 2X12 BEAM?. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 F)SPECIFY CALCULATED UPLIFT AT THE ENDS
 OF REAR PORCH BEAMS. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 G)CONNECTOR SPECIFIED FOR TRUSSES ON TOP
 OF (3)2X12 BEAM IS FOR WOOD TO MASONRY
 CONDITION. NEED WOOD TO WOOD CONNECTOR
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 16-SHEET S-3: A)UPDATE GENERAL NOTES.
 SEE CHAPTER 19 AND 35 FOR SPECIFIC
 REFERENCE STANDARDS AND EDITION USED
 FOR CONCRETE CONSTRUCTION.
 B)BUCK DETAIL DOESN'T MATCH BUCK DETAILS
 ON SHEET A-4. NEED ONLY ONE DETAIL TO
 AVOID CONFLICTS. REVISE DETAIL TO
 COMPLY WITH SEC. 1707.4.4.2 FBC 2001.
 SHOW FULL DOOR/WINDOW SUPPORT AND NO
 BEVELED EDGE.
 C)REVISE TYP. FOOTING SECTION. NEED 1.5"
 WATER RECESS. SEC. 2111.1.9 CITY
 AMENDMENTS TO FBC 2001.
 D)REVISE ROOF SHEATHING SPECS ON DETAIL
 2-S3 TO MATCH SPECS ON SHEET A-2/A-2.1
  
 17-REVISE ALL GENERAL NOTES WHERE IT
 SAYS "ARCHITECT". THIS PLANS WERE
 PREPARED BY AN ENGINEER, NOT ARCHITECT
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 805-6712.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-07-27 Cont ID  
Sent By btrobaug Date 2004-07-27 Time 14:54 Rev Time 0.50
Received By btrobaug Date 2004-07-27 Time 12:44 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-05-25 Cont ID  
Sent By csiegber Date 2004-07-21 Time 16:01 Rev Time 0.50
Received By btrobaug Date 2004-05-24 Time 14:19 Sent To M
Notes
2004-05-24 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INCLUDE ALL LICENSE
 #'S ON THE REQUIRED TITLE BLOCK.
 PLEASE ALSO INCLUDE CERTIFICATE OF
 AUTHORIZATION #'S WHERE REQUIRED
 PER FS 471.023, FAC 61G15-23.002
 (ENG'S)PER FS 481.219, FAC 61G1-16.004
 THERE IS NO TITLE BLOCK ON THE PLANS.
  
 2} THE RISER INDICATES A 150 AMP
 CIRCUIT BREAKER PANEL WITH A 200 AMP
 DISCONNECT. SEE 408.16, OCP TOO LARGE
 FOR THE PANEL. THE 1/0 FEEDERS SHOWN
 MUST BE PROTECTED BY NOT MORE THAN A
 175 AMP BREAKER. PLEASE CORRECT THE
 RISER DIAGRAM.
  
 3} THE LAUNDRY CIRCUIT MUST COMPLY WITH
 220.11(C)(3),20AMPS,SEE PANEL SCHEDULE.
  
 4} THE KITCHEN COUNTERTOP RECEPTACLE
 SPACING MUST COMPLY WITH 210.52(C)(1).
  
 5} SMOKE DETECTORS MUST BE INSTALLED PER
 8-1.4.1.6.2 NFPA-72. PLEASE SHOW SAME
 ON PLANS.
  
 6} RECEPTACLE SPACING IN THE MASTER BED
 ROOM MUST COMPLY WITH 210.52. AT LEAST
 ONE RECEPTACLE MUST BE ADDED, SEE
 REVIEWED SET.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-07-21 Cont ID  
Sent By csiegber Date 2004-07-21 Time 16:01 Rev Time 0.00
Received By csiegber Date 2004-07-21 Time 16:01 Sent To E
Notes
2004-07-21 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-06-18 Cont ID  
Sent By mmclean Date 2004-05-20 Time 14:34 Rev Time 0.00
Received By jgomez Date 2004-05-19 Time 16:46 Sent To PC
Notes
2004-05-20 00:00:00TO SFD RACK/E
2004-05-19 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-05-28 Cont ID  
Sent By btrobaug Date 2004-05-25 Time 09:09 Rev Time 0.35
Received By pkrauss Date 2004-05-28 Time 12:50 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2004-05-29 Cont ID  
Sent By pkrauss Date 2004-05-28 Time 12:58 Rev Time 0.33
Received By jleech Date 2004-05-29 Time 07:10 Sent To B
Notes
2004-05-29 00:00:00NO PLUMBING PLAN REVIEW. NOT ENOUGH
 INFORMATION. NO PLUMBING RISER DIAGRAM.

Review Stop Z ZONING
Rev No 1 Status P Date 2004-05-20 Cont ID  
Sent By mmclean Date 2004-05-20 Time 14:34 Rev Time 0.00
Received By mmclean Date 2004-05-20 Time 14:34 Sent To I
Notes
***NONE***